Unable to set Virtual Node GUID on ConnectX-6 VPI card.

Description
While IO identity is enabled, setting Virtual Node GUID through SCP import or any other iDRAC interfaces, the adapter would still display the original value unless the update has gone through SSM.
Workaround
Disable the IO identity and then set the value.
Systems affected
All systems supported by this release
Tracking number
170720