Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC9 with Lifecycle Controller Version 3.36.36.36 Release Notes

PDF

Storage and storage controllers

  1. While renaming a virtual disk (VD), using a . (period) is not allowed in the VD name.
  2. If your system has a PERC card configured in Enhanced HBA mode and you downgrade iDRAC to an older version, the SET commands for storage configuration may fail. To resolve the issue, ensure that a Collect System Inventory On Reboot (CSIOR) is performed after the downgrade. To perform a CSIOR, use the following methods:
    1. Completely turn off the system and then turn it on again.
    2. Ensure that CSIOR is enabled before turning off the system.
    3. Use the following RACADM command: racadm serveraction powercycle

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\