  1. Due to known limitations in OpenSource (SFCB), query filtering with long integers and lengthy strings may not work as expected.
  2. LC can import and view an iDRAC license but cannot export or delete the iDRAC license. The iDRAC license can be deleted from iDRAC web interface.
  3. The iSCSI offload attribute can be enabled only on two of the four available ports. If a card, which has this attribute that is enabled on two of its ports, is replaced with another card that has the attribute that is enabled on the other two ports, an error occurs. The firmware does not allow the attribute to be set because it is already set on the other two ports.
  4. The "Discovered Servers" view of Group Manager may not show available iDRACs as available to onboard. Verify that the iDRACs are on the same link local network and not separated by a router. If they are still not visible, reset the Group Manager's controlling iDRAC.
    1. Open Group Manager on one of the member iDRACs.
    2. In the search box, type the controlling system's Service Tag.
    3. Double-click the iDRAC that matches the search results and go to iDRAC Settings -> Diagnostics.
    4. Select Reset iDRAC

    When iDRAC fully restarts, Group Manager should see the new iDRAC.

  5. After downgrading iDRAC from version 3.30.30.30 to version 3.00.00.00, 3.11.11.11, or 3.15.15.15, the jobs created in the job queue are deleted. Recreate the jobs after the downgrade is complete.
  6. On PowerEdge R6415, R7415, R7425, if you downgrade iDRAC firmware from version 3.30.30.30 to an earlier version, some certificate-related operations may not function properly and certain hardware information may not be displayed correctly. To resolve the issue, reset iDRAC using the 'racresetcfg' command.
  7. Remote syslog settings may not be retained after iDRAC firmware is downgraded from version 3.30.30.30 to an older version. Ensure that you reconfigure the remote syslog settings after downgrading the iDRAC firmware.
  8. During import server profile operation, if the image filename is "Backup.img", operation may fail. To avoid this failure, change the filename.
  9. iDRAC upgrade from 3.34.34.34 to 3.36.36.36 fails from remote RACADM with session invalid error.