Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

SWU Event Messages

SWU001

Message
The expander or storage enclosure processor firmware is successfully updated.
Detailed Description
The expander or storage enclosure processor firmware is successfully updated.
Recommended Response Action
No response action is required.
Category
Storage (SWU = Software Change)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

SWU002

Message
The backplane firmware update did not complete successfully.
Detailed Description
The expander or storage enclosure processor firmware update did not complete successfully.
Recommended Response Action
Check the Storage Enclosure Backplane type and the Firmware version and make sure they are appropriately matched, and then retry the operation. For more information, see the platform Owners Manual
Category
Storage (SWU = Software Change)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

SWU8500

Message
The arg1 request to Lifecycle Controller on server arg2 was not successful.
Arguments
arg1 = update/reinstall/rollback, arg2 = slot number
Detailed Description
This message is displayed when: 1. A reboot job is unable to provide a valid reboot ID. 2. The WSMAN command to set up a job queue on Lifecycle Controller was not successful.
Recommended Response Action
Retry the operation. If the error persists, contact your service provider.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8501

Message
The reinstall/rollback request to Lifecycle Controller on server arg1 was not successful.
Arguments
arg1 = slot number
Detailed Description
This message is displayed when: 1. A reboot job is unable to provide a valid reboot ID. 2. The WSMAN command to set up a job queue on Lifecycle Controller was not successful.
Recommended Response Action
Retry the operation. If the error persists, contact your service provider.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8502

Message
A arg1 request was submitted to the Lifecycle Controller on server arg2 .
Arguments
arg1 = update/reinstall/rollback, arg2 = slot number
Detailed Description
The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria.
Recommended Response Action
No response action required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8503

Message
A reinstall/rollback request was submitted to the Lifecycle Controller on server arg1 .
Arguments
arg1 = slot number
Detailed Description
The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria.
Recommended Response Action
No response action required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8504

Message
Successfully scheduled the arg1 operation on the server arg2 .
Arguments
arg1 = update/reinstall/rollback, arg2 = slot number
Detailed Description
The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria.
Recommended Response Action
No response action required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8505

Message
Successfully scheduled the reinstall/rollback operation on the server arg1 .
Arguments
arg1 = slot number
Detailed Description
The specified Lifecycle Controller operation is successfully submitted and the operation will be executed on the basis of scheduling criteria.
Recommended Response Action
No response action required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8506

Message
Completed the Firmware update operation for CMC arg1 .
Arguments
arg1 = slot number
Detailed Description
Completed the Firmware update operation for the CMC identified in the message..
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8513

Message
Successfully updated the IOM infrastructure firmware of slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The firmware update operation of IOM infrastructure is successful.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8514

Message
Unable to update the IOM infrastructure firmware of slot arg1 . ErrorCode=0x arg2 .
Arguments
arg1 = slot number, arg2 = error no
Detailed Description
The IOM infrastructure firmware update operation is not successful.
Recommended Response Action
Reacquire the Image file from the source folder, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8515

Message
Unable to update the IOM firmware. Update Initiation was not successful. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The IOM firmware update operation was not successful. Unable to initiate the Update process.
Recommended Response Action
Retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8516

Message
Unable to update the iDRAC firmware on the server in slot arg1 . Transfer is not successful. ErrorCode=0x arg2 .
Arguments
arg1 = slot number, arg2 = error no
Detailed Description
iDRAC firmware update operation was not successful. The firmware Image file could not be transferred.
Recommended Response Action
Make sure the iDRAC firmware Image file is available in the given path and retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8517

Message
Unable to update the iDRAC firmware on the server in slot arg1 . The Image file is not accessible. ErrorCode=0x arg2 .
Arguments
arg1 = slot number, arg2 = error no
Detailed Description
Unable to update the iDRAC firmware. The firmware Image file is not accessible.
Recommended Response Action
Make sure the iDRAC firmware Image file is available in the given path and retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8518

Message
The firmware update operation on the iDRAC on the server in slot arg1 is stopped.
Arguments
arg1 = slot number
Detailed Description
The server was pulled out from the chassis during the iDRAC firmware update operation.
Recommended Response Action
Reinsert the server and retry the operation. If the issue persists, contact your service provider.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8519

Message
The firmware update operation of the iDRAC on the server in slot arg1 is stopped. The Image file is corrupted.
Arguments
arg1 = slot number
Detailed Description
The iDRAC firmware update operation was stopped, because the Image file is corrupted.
Recommended Response Action
Reacquire the Image file from the original source, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8520

Message
The firmware update operation of the iDRAC on the server in slot arg1 is not successful.
Arguments
arg1 = slot number
Detailed Description
The firmware update operation of the iDRAC identified in the message is not successful.
Recommended Response Action
Reacquire the Image file from the original source, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8521

Message
The firmware update operation of the iDRAC on the server in slot arg1 was stopped. The selected Image file is not compatible with the server hardware.
Arguments
arg1 = slot number
Detailed Description
The firmware update operation of iDRAC identified in the message was stopped. The selected Image file is not compatible with the server hardware.
Recommended Response Action
Make sure that the Image file is compatible with the server hardware, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8522

Message
Unable to update the iDRAC on the server in arg1 firmware: ErrorCode=0x arg2 .
Arguments
arg1 = slot number, arg2 = error no
Detailed Description
The firmware update operation is not successful.
Recommended Response Action
Reacquire the Image file from the original source, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8523

Message
The firmware update operation of the iDRAC on the server in slot arg1 is successfully completed.
Arguments
arg1 = slot number
Detailed Description
The firmware update operation of the iDRAC identified in the message is successful.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8524

Message
Unable to update the iDRAC on the server in slot arg1 firmware: ErrorCode=0x arg2 .
Arguments
arg1 = slot number, arg2 = error no
Detailed Description
The firmware update operation is not successful. This may be due to a problem encountered by the firmware, or because a server was removed during the firmware update operation.
Recommended Response Action
Reacquire the Image file from the source folder, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8525

Message
Unable to update the iDRAC firmware on the server in slot arg1 . The firmware update timeout limit is exceeded.
Arguments
arg1 = slot number
Detailed Description
The firmware update operation is not successful. The update process was not completed within the firmware update timeout duration.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8526

Message
The firmware update operation of the iDRAC on the server in slot arg1 is initiated.
Arguments
arg1 = slot number
Detailed Description
The firmware update operation of iDRAC identified in the message is initiated.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8527

Message
Successfully completed the iKVM firmware update.
Detailed Description
The iKVM firmware update operation is successful.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8528

Message
Unable to update the iKVM firmware, because of a checksum error.
Detailed Description
The process of iKVM firmware update is not successful due to a checksum error of the firmware image.
Recommended Response Action
Reacquire the Image file from the source folder, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8529

Message
Unable to update the iKVM firmware, because the Image file was not transferred to the iKVM target.
Detailed Description
The iKVM firmware update operation was not successful, because the firmware Image file could not be transferred to the target.
Recommended Response Action
Make sure that the iKVM firmware Image file is available at the specified location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8530

Message
Unable to update the iKVM firmware.
Detailed Description
The process for iKVM firmware update was not successful.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8531

Message
Unable to update the iKVM firmware. The firmware update timeout limit is exceeded.
Detailed Description
The firmware update operation is not successful, because the Update process was not completed within the firmware update timeout duration.
Recommended Response Action
Retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8532

Message
Unable to update the LKVM firmware, because an invalid parameter is entered. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The LKVM firmware update operation is not successful, because an invalid parameter is entered.
Recommended Response Action
Retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8533

Message
Unable to update the LKVM firmware, because the target is not ready. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The LKVM firmware update operation is not successful, because the target is not ready.
Recommended Response Action
Wait for the target to become ready. This may take a few minutes. After the target is ready, then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8534

Message
Unable to update the iKVM firmware.
Detailed Description
The iKVM firmware update operation is not successful.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8535

Message
Unable to update the LKVM firmware, because the Image file transfer is not successful. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The LKVM firmware update operation was not successful, because the firmware Image file could not be transferred.
Recommended Response Action
Make sure that the iKVM firmware image file is available at the specified location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8536

Message
Unable to update the LKVM firmware, because the Image file could not be accessed. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The LKVM firmware update operation was not successful, because the firmware Image file could not be transferred.
Recommended Response Action
Make sure that the iKVM firmware image file is available at the specified location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8537

Message
Unable to update the LKVM firmware, because the IP address provided is invalid. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The LKVM firmware update operation was not successful, because the IP address of the active CMC that is provided to the LKVM is invalid.
Recommended Response Action
Make sure the CMC IP address entered is valid, and then retry the Update operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8538

Message
Unable to update the iKVM firmware. Reason = 0x arg1 .
Arguments
arg1 = error no
Detailed Description
The iKVM firmware update operation was not successful.
Recommended Response Action
Retry the Update operation. If the issue persists, reinsert the iKVM and retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8540

Message
Unable to update the PSU firmware, because the transfer of Image file is not successful. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The PSU firmware update operation was not successful, because the firmware Image file could not be transferred.
Recommended Response Action
Make sure that the PSU firmware image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8541

Message
Unable to update the PSU firmware, because the Image file is not accessible. ErrorCode=0x arg1 .
Arguments
arg1 = error no
Detailed Description
The PSU firmware update operation was not successful, because the firmware Image file could not be transferred.
Recommended Response Action
Make sure that the PSU firmware image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8542

Message
Unable to update the Active CMC firmware. The Image file transfer process was not successful.
Detailed Description
The firmware update operation for the CMC was not successful. The Image file could not be transferred.
Recommended Response Action
Make sure that the CMC firmware Image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8543

Message
Unable to update the Active CMC firmware. The Image file was not accessible.
Detailed Description
The firmware update operation of CMC was not successful. The Image file was not accessible.
Recommended Response Action
Make sure that the CMC firmware image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8544

Message
Unable to update the Standby CMC firmware because the Standby CMC could not be prepared for firmware update.
Detailed Description
The firmware update operation of the Standby CMC was not successful. The Standby CMC could not be prepared for firmware update.
Recommended Response Action
Retry the firmware update operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8545

Message
Unable to update the Standby CMC firmware.
Detailed Description
The firmware update operation of the Standby CMC was not successful.
Recommended Response Action
Retry the update operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8546

Message
Unable to update the Standby CMC firmware.
Detailed Description
The firmware update operation of the Standby CMC was not successful.
Recommended Response Action
Retry the update operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8547

Message
Unable to update the Standby CMC firmware. The Image transfer process was not successful.
Detailed Description
The firmware update operation of Standby CMC was not successful. The firmware image could not be transferred.
Recommended Response Action
Make sure that the CMC firmware image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8548

Message
Unable to update the Standby CMC firmware. The Image was not accessible.
Detailed Description
The firmware update operation of Standby CMC was not successful. The firmware image could not be accessed.
Recommended Response Action
Make sure that the CMC firmware image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8549

Message
Unable to update the firmware of Standby CMC and Active CMC. The checksum process was not successful.
Detailed Description
The firmware update process of Active CMC and Standby CMC was not successful, because of a firmware image checksum error.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8550

Message
Unable to update the firmware of Standby CMC and Active CMC.
Detailed Description
The firmware update process of Active CMC and Standby CMC was not successful.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8551

Message
Unable to update the firmware of Active CMC. The checksum process was not successful.
Detailed Description
The firmware update process of Active CMC was not successful, because of a firmware image checksum error.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8552

Message
Unable to update the firmware of Active CMC.
Detailed Description
The firmware update process of Active CMC was not successful.
Recommended Response Action
Reacquire the Image file from the source location, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8553

Message
Unable to update the Active CMC firmware. The Image file was not accessible.
Detailed Description
The firmware update operation of Active CMC was not successful. The firmware Image file could not be accessed.
Recommended Response Action
Make sure that the CMC firmware Image file is available at the location specified in the operation, and then retry the operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8554

Message
Local CMC firmware update has been initiated.
Detailed Description
Local CMC firmware update process is initiated.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

SWU8555

Message
Active CMC and Standby CMC firmware updates have been initiated.
Detailed Description
Active and Standby CMC firmware update process is initiated.
Recommended Response Action
No response action is required.
Category
Updates (SWU = Software Change)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

SWU8556

Message
Unable to configure the sled network uplink on sled arg1 .
Arguments
arg1 = slot number
Detailed Description
The sled network uplink on the sled identified in the message could not be configured. The servers on the sled may not have expected network connectivity.
Recommended Response Action
Perform a Virtual Reseat operation, and then retry the operation. To virtually reseat a server 1) Using the CMC Web UI, go to Chassis Overview > Troubleshooting > Reset Components, and then select slot for the component identified in the message and apply the Virtual Reseat or 2) Run the following RACADM command at the command line interface: "racadm serveraction -f -m sled-<slot number> reseat".
Category
Audit (SWU = Software Change)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8557

Message
Invalid firmware: The uploaded firmware image does not contain a verification signature.
Detailed Description
Invalid firmware: The uploaded firmware image does not contain a verification signature.
Recommended Response Action
Use a valid firmware image and retry the operation.
Category
Audit (SWU = Software Change)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

SWU8558

Message
Invalid firmware: The uploaded firmware image validation was unsuccessful.
Detailed Description
Invalid firmware: The uploaded firmware image validation was unsuccessful.
Recommended Response Action
Use a valid firmware image and retry the operation.
Category
Audit (SWU = Software Change)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

SWU8559

Message
The firmware downgrade operation is unsuccessful. A downgrade to the firmware version uploaded is not supported.
Detailed Description
The firmware downgrade operation is unsuccessful. A downgrade to the firmware version uploaded is not supported.
Recommended Response Action
Refer to the platform Owners Manual for more information or contact your service provider.
Category
Audit (SWU = Software Change)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

SWU8560

Message
The firmware update process of Active CMC and Standby CMC was not successful because of a unrecognized image error.
Detailed Description
The firmware update process of Active CMC and Standby CMC was not successful because of a unrecognized image error.
Recommended Response Action
Obtain a valid firmware image from your service provider and retry the operation.
Category
Audit (SWU = Software Change)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

SWU8561

Message
Unable to downgrade the firmware version because the current hardware configuration does not support rollback to the earler firmware version.
Detailed Description
The firmware version selected for rollback does not support the current chassis hardware configuration.
Recommended Response Action
Make sure that firmware version selected for rollback is supported for the current hardware configuration, such as I/O modules, PSU modules, and servers. For example, a newer generation PSU may not work with an earlier iDRAC or CMC firmware. For more information, see the platform Owners Manual or CMC or iDRAC Release Notes for details.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
Trap/EventID
6314
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔*  
CMC   ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SWU8662

Message
Unable to update the I/O Aggregator (IOA) firmware because of an issue in the network communication session between CMC and IOA in slot arg1 .
Arguments
arg1 = slot ID
Detailed Description
The IOA firmware cannot be updated because of an issue in the network communication session between CMC and IOA.
Recommended Response Action
Power-cycle the IOA and if the firmware version is unchanged, retry the firmware update operation.
Category
Updates (SWU = Software Change)
Severity
Severity 2 (Warning)
Trap/EventID
6314
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\