RAC Event Messages

RAC001

Message
The command was successful.
Detailed Description
The command was successful.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC002

Message
General failure.
Detailed Description
An unknown error occurred.
Recommended Response Action
Do one of the following: 1) Rerun the command. 2) Reset iDRAC and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC003

Message
Missing required parameter arg1 .
Arguments
arg1 = parameter name
Detailed Description
One or more required parameters for the method are missing.
Recommended Response Action
Refer to the profile document and provide the required parameters.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC004

Message
Invalid parameter value for arg1 .
Arguments
arg1 = parameter
Detailed Description
The parameter value for the given parameter is invalid.
Recommended Response Action
Provide a valid parameter value for specified parameter.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC005

Message
Mismatch in AttributeName and AttributeValue count.
Detailed Description
The name value pairs do not match in the input specified in the method invocation parameters.
Recommended Response Action
Provide a valid (AttributeName, AttributeValue) pair.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC006

Message
The attribute value cannot be changed because it is of read-only type.
Detailed Description
The attribute value cannot be changed because it is of read-only type.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC007

Message
The attribute value is outside the acceptable range.
Detailed Description
The attribute value is outside the acceptable range.
Recommended Response Action
Enter a value within the range and retry the operation. For more information about the acceptable range, refer to the Dell Lifecycle Controller Remote Services Quick Start Guide and DCIM Profile Documents available at the support site.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC008

Message
Invalid boolean Value
Detailed Description
The attribute boolean value is not valid for the specified attribute.
Recommended Response Action
Provide valid boolean value for the specified attribute.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC009

Message
Input string length exceeds maximum length.
Detailed Description
The requested operation cannot be completed because the length of the input string exceeds maximum length allowed.
Recommended Response Action
Verify the string length and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC010

Message
Input contains invalid character.
Detailed Description
The input value for the attribute being set contains characters that are not allowed.
Recommended Response Action
Retry the operation using valid input characters. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0100

Message
The Smart Card is removed. Further communication is not possible.
Detailed Description
Communication with the Smart Card has been lost.
Recommended Response Action
Insert a valid Smart Card and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0101

Message
The inserted Smart Card is not valid or the Smart Card reader is not supported.
Detailed Description
The data returned is not in a known format.
Recommended Response Action
This error may occur because: 1. Smart Card is invalid. Insert a valid Smart Card and try again. 2. Check connection between reader and system. 3. There may be an issue with the Smart Card reader. Try reinstalling the reader driver or use a different reader.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0102

Message
The Smart Card Logon plug-in is not installed. Install the plug-in from the iDRAC Web GUI to log in using Smart Card.
Detailed Description
The software to communicate with the Smart Card is not loaded in this browser. Smart Card can be used for log in only if the appropriate Smart Card software is installed in the browser.
Recommended Response Action
Install the plug-in prompted by the iDRAC Web GUI to log in using Smart Card.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0103

Message
This browser does not support Smart Card logon on iDRAC. Use Internet Explorer version 7.0 or later to use this feature.
Detailed Description
Smart Card login is only supported in newer versions of Internet Explorer.
Recommended Response Action
See the iDRAC help text or documentation for a list of supported browsers.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0104

Message
An incorrect PIN was entered.
Detailed Description
An invalid PIN was entered. Too many log in attempts with a Smart Card login can result in a user being locked out of the system.
Recommended Response Action
1. Enter a valid Smart Card PIN and try again. 2. Use a different Smart Card.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0105

Message
The Smart Card reader cannot be detected. Check whether the reader is installed correctly.
Detailed Description
Communication with the Smart Card reader cannot be established, or is lost.
Recommended Response Action
This error may occur because: 1. Check connection between reader and system. 2. There may be an issue with the Smart Card reader. Try reinstalling the reader driver or use a different reader.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0106

Message
The Smart Card cannot be detected. Insert the Smart Card correctly.
Detailed Description
Communication with the Smart Card reader is established and a Smart Card is inserted, but there are problems reading the Smart Card.
Recommended Response Action
This error may occur because: 1. Make sure the Smart Card is seated correctly. 2. Smart Card is invalid. Insert a valid Smart Card and try again. 3. Check connection between reader and system. 4. There may be an issue with the Smart Card reader. Try reinstalling the reader driver or use a different reader.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0107

Message
The inserted Smart Card cannot be recognized. Ensure that the correct Smart Card CSP drivers are installed.
Detailed Description
Communication with the Smart Card reader is established and a Smart Card is inserted, but there are problems accessing the Smart Card. The appropriate Cryptographic Service Provider (CSP) drivers are not installed.
Recommended Response Action
There may be an issue with the Smart Card Cryptographic Service Provider (CSP) drivers. Use the client OS to install CSP driver. If the OS has problem with Smart Card, then there will have problem using the Smart Card. So make sure Smart Card can login with Windows OS.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0108

Message
An internal error is encountered. Insert a valid Smart Card and try again. (Does this and preceeding messages show up in the SEL?)
Detailed Description
A non-specific error is detected when accessing the Smart Card.
Recommended Response Action
Review the error message preceeding or following this message.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC011

Message
A configuration Job already exists, cannot process more set operations.
Detailed Description
A Job has already been scheduled to apply pending iDRAC attribute values. Additional configuration operations are not allowed while there is a configuration Job pending execution.
Recommended Response Action
Wait for the scheduled Job to complete before setting more attributes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0113

Message
Remote Syslog Port value is invalid: Valid range is 1-65535 or 0x1-0xFFFF.
Detailed Description
Data entered is not an integer value in the valid range of numbers.
Recommended Response Action
Enter a Remote Syslog Port number. Expected range: [1-65535 or 0x1-0xFFFF]
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0115

Message
The Destination IP Address value is invalid.
Detailed Description
The IPv4 address does not conform to the addressing standard or the supported IPv4 address range.
Recommended Response Action
Enter the Destination IP Address value between [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0116

Message
Invalid Destination IPv6 Address.
Detailed Description
The entered IPv6 address does not conform to the addressing standard or the supported IPv6 address range.
Recommended Response Action
Enter a valid Destination IPv6 Address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0117

Message
SD card is unavailable.
Detailed Description
The SD card is not present, or communication with the SD card is lost. This could result in reduced functionality and capabilities.
Recommended Response Action
This error may occur because: 1. Make sure the SD card is seated correctly. 2. The SD card is invalid. Insert a valid SD card of size greater than 256MB and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0118

Message
Unsupported vFlash SD card detected.
Detailed Description
The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions.
Recommended Response Action
Insert a supported vFlash SD card.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC012

Message
Unable to perform the operation because of insufficient user privileges.
Detailed Description
The user credentials supplied do not have sufficient privileges to perform the operation.
Recommended Response Action
Retry the operation with user credentials authorized for the requested operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0120

Message
The selected partition size exceeds the available space.
Detailed Description
Requested partition size exceeds the available space.
Recommended Response Action
Enter a partition size smaller than the unused space on the vFlash SD card.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0121

Message
SD card is not initialized.
Detailed Description
SD card not readable. The card must be initialized.
Recommended Response Action
Initialize the SD card before it can be used.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0124

Message
Invalid label: Label must be exclusively alphanumeric characters.
Detailed Description
All characters in the label must be alphanumeric.
Recommended Response Action
Enter all alphanumeric characters.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0126

Message
The label value is invalid. Expected range: 1-6 alphanumeric characters.
Detailed Description
The label field is empty. A label is required to create an empty partition.
Recommended Response Action
Enter a label that contains one to six alphanumeric characters.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0127

Message
The specified size must be a non-fractional numeric value.
Detailed Description
Size must be a whole number.
Recommended Response Action
Enter a whole number for the size field.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0128

Message
An error has occurred in vFlash.
Detailed Description
A non-specific error has been detected while accessing the vFlash.
Recommended Response Action
Try the operation again in a few minutes. If the problem persists, reset iDRAC before trying the operation again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0129

Message
An error has occurred while initializing the SD card.
Detailed Description
No status response was returned after completing the initialization request.
Recommended Response Action
Try reinitalizing the card again in a few minutes.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC013

Message
Unable to run the method becuase an invalid FQDD is entered.
Detailed Description
The method cannot be run because an invalid FQDD is entered.
Recommended Response Action
Enter a valid FQDD and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0130

Message
An error has occurred while creating a partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while creating the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0131

Message
An error has occurred while deleting a partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while deleting the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0132

Message
An error has occurred while formatting a partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while formatting the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0133

Message
An error has occurred while downloading a partition.
Detailed Description
A non-specific error has been detected when downloading the partition.
Recommended Response Action
Try downloading the partition again in a few minutes. If the problem persists, reset iDRAC before trying the operation again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0134

Message
This operation is unavailable for non-vFlash SD cards.
Detailed Description
The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions.
Recommended Response Action
Insert a valid vFlash SD card.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0135

Message
An error has occurred while detaching a partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while detaching the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0136

Message
An error has occurred while attaching a partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while attaching the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0137

Message
An error has occurred while changing the read-write state for the partition.
Detailed Description
A seperate message will provide more detail about this error which was detected while changing the read-write state of the vFlash partition.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0138

Message
A valid certificate is not loaded.
Detailed Description
The retrieved certificate came back as a null or empty document.
Recommended Response Action
Upload a valid certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC014

Message
Unable to run the method becuase an invalid attribute name is entered.
Detailed Description
The method cannot be run because an invalid attribute name is entered.
Recommended Response Action
Enter a valid attribute name and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0140

Message
Firmware update has failed.
Detailed Description
The firmware update process returned an Update Failed status.
Recommended Response Action
Try the firmware update again in a few minutes. If the problem persists, try uploading the firmware through another interface such as Web GUI, RACADM, or DUPs.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0141

Message
Firmware update verification failed: The update status is unknown.
Detailed Description
Firmware update verification process failed; the firmware update status is unknown.
Recommended Response Action
Verify if the firmware has been updated by checking the new firmware version number. If it has not been updated try the firmware update again in a few minutes. If the problem persists, try uploading the firmware through another interface such as Web GUI, RACADM, or DUPs.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0142

Message
File is not valid for iDRAC firmware update.
Detailed Description
The firmware update process identified an invalid firmware image.
Recommended Response Action
Upload a valid iDRAC firmware image.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0146

Message
Firmware rollback has failed.
Detailed Description
Firmware rollback operation failed.
Recommended Response Action
Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0147

Message
Rollback firmware is not available.
Detailed Description
Firmware rollback image is missing or is corrupt.
Recommended Response Action
Upload a new firmware image.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0148

Message
Unable to retrieve the batteries information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about the batteries.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0149

Message
Unable to retrieve the fan information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about the fans.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC015

Message
Unable to run the method becuase the input value is not one of the possible values for AttributeName arg1 .
Arguments
arg1 = attribute name
Detailed Description
The input attribute value is not valid for the attribute identified in the message.
Recommended Response Action
Provide valid attribute value for the attribute identified in the message and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0150

Message
Unable to retrieve the intrusion sensor information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about system intrusion.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0151

Message
Unable to retrieve the removable flash media information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about removable flash media.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0152

Message
Unable to retrieve the power supply information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about power supplies.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0153

Message
Non-redundant power mode: Check the system hardware manual for implications.
Detailed Description
Power redundancy is typically used to protect equipment from unexpected power disruption that could cause data loss or hardware damage.
Recommended Response Action
It is recommended to use power redundancy
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0154

Message
Non-redundant power mode: Secondary power supply has degraded.
Detailed Description
Displayed when a group of redundant power supplies has one or more individual power supplies with bad status.
Recommended Response Action
Replace the degraded power supply unit. Check the Power Supplies page for more information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0155

Message
Unable to retrieve the temperature information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about system temperature.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0156

Message
Unable to retrieve the voltage information. The system is powered off.
Detailed Description
While the system is powered off it is unable to retrieve information about system voltage.
Recommended Response Action
Turn the system on to view this information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0158

Message
Uploading kerberos keytab has failed.
Detailed Description
The Kerberos keytab is needed by the iDRAC to authenticate itself to the Kerberos (Active Directory) server. It is created on the AD server, and issued for the iDRAC. Its like a password, and therefore should be kept secret.
Recommended Response Action
The Kerberos keytab file may be corrupt. Upload a valid Kerberos keytab file.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0159

Message
Certificate upload failed: No pending CSR or private key.
Detailed Description
Certificate upload failed because there is no pending Certificate Signing Request (CSR) or private key.
Recommended Response Action
Upload failed due to no pending Certificate Signing Request (CSR). Try creating a new CSR and then upload the certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC016

Message
Unable to run the method becuase an invalid attribute name is entered.
Detailed Description
The method cannot be run because an invalid attribute name is entered.
Recommended Response Action
Enter a valid attribute name and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0160

Message
Certificate upload failed: Cannot validate the certificate.
Detailed Description
Certificate upload failed because the certificate could not be validated.
Recommended Response Action
Certificate may be corrupt. Try creating a new Certificate Signing Request (CSR) and then upload the certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0169

Message
Certificate upload failed: Certificate is not valid.
Detailed Description
Certificate upload failed because the certificate is not valid.
Recommended Response Action
Certificate may be corrupt. Try creating a new Certificate Signing Request (CSR) and then upload the certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC017

Message
Job created to apply the attribute value.
Detailed Description
The requested job has been created.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0171

Message
Certificate upload failed: Certificate has expired.
Detailed Description
Certificate upload failed because the certificate has expired.
Recommended Response Action
Certificate has expired. Try creating a new Certificate Signing Request (CSR) and then upload the certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC018

Message
The Job is completed but with errors..
Detailed Description
All the tasks in the Job were attempted, but some did not complete successfully.
Recommended Response Action
Examine source of the errors by inspecting the results from the Job execution, and after resolving the issues, retry the operation. Job results can be retrieved from the Lifecycle Log or the WSMan API.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0180

Message
Certificate upload failed: Unable to get local issuer certificate from the Certification Authority (CA) for confirming the CA is legitimate.
Detailed Description
Certificate upload failed. Unable to get local issuer certificate. The local issuer certificate is the certificate for the Certificate Authority (CA) that has signed the certificate for the Active Directory (AD) server, unless it is self signed. The iDRAC needs to verify that the CA is legitimate.
Recommended Response Action
Certificate has expired. Try creating a new CSR and then upload the certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC019

Message
Job did not complete successfully.
Detailed Description
The submitted job did not complete successfully.
Recommended Response Action
Examine source of the errors by inspecting the results from the job execution, and after resolving the issues, retry the operation. Job results can be retrieved from the Lifecycle Log or the WSMan API.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC020

Message
Completed
Detailed Description
The submitted job completed successfully.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0206

Message
Certificate upload failed: Not a certificate file.
Detailed Description
Certificate upload failed because this is not a certificate file.
Recommended Response Action
Upload a valid certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0207

Message
Certificate upload failed.
Detailed Description
Certificate upload failed possibly due to poor network connection.
Recommended Response Action
Try the operation again in a few minutes. If the problem persists, issue a new Certificate Signing Request (CSR) and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0208

Message
Upload failed: May be due to invalid key data.
Detailed Description
Upload failed possibly due to invalid key data.
Recommended Response Action
Upload a certificate with a valid key.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0209

Message
Certificate upload failed: iDRAC unable to upload at this time.
Detailed Description
Certificate upload failed because iDRAC unable to upload at this time.
Recommended Response Action
Try the operation again in a few minutes.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC021

Message
Unable to set static values for IPAddress Net mask or Gateway because DHCP is Enabled.
Detailed Description
The static values for IPAddress Net mask or Gateway cannot be set because DHCP is enabled.
Recommended Response Action
Disable DHCP to set static values for IPAddress Net mask or Gateway.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0211

Message
Firmware update has failed.
Detailed Description
Firmware update has failed. This may be due to a corrupt firmware image, poor network connection, or another issue.
Recommended Response Action
Download a new firmware image and try loading the firmware again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0212

Message
Login failed. Verify that username and password is correct.
Detailed Description
This is a generic error message used on all the login pages.
Recommended Response Action
Enter valid credentials.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0213

Message
Missing Username.
Detailed Description
Login page is missing a username.
Recommended Response Action
Enter a valid username.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0214

Message
Missing Password.
Detailed Description
Login page is missing a password.
Recommended Response Action
Enter a valid password.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0215

Message
Login failed: User does not have Login to iDRAC privilege.
Detailed Description
Login failed because the user does not have Login to iDRAC privilege.
Recommended Response Action
Login to iDRAC privilege is needed.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0216

Message
Login failed.
Detailed Description
Login failed because of an unknown reason.
Recommended Response Action
Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0217

Message
iDRAC is not responding.
Detailed Description
Client did not receive a response for the login request.
Recommended Response Action
Try pinging the iDRAC and then try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0218

Message
The maximum number of user sessions is reached.
Detailed Description
A maximum of 4 iDRAC Web GUI sessions can be open at any time.
Recommended Response Action
Close one or more sessions before opening another session.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0219

Message
Power command failed.
Detailed Description
Requested power state change has failed.
Recommended Response Action
Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC022

Message
Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured.
Detailed Description
Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the User Name is not configured.
Recommended Response Action
Set User Name before attempting to set values of other identified attributes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0221

Message
The Destination E-mail Address is too long. The maximum length is 64 characters.
Detailed Description
The Destination E-mail Address can contain upto 64 characters.
Recommended Response Action
Enter an email address that contains upto 64 characters.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0222

Message
The Destination E-mail Address is invalid.
Detailed Description
The specified email address does not match an email address format. Ex: "janedoe@email.com."
Recommended Response Action
Enter a valid email address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0223

Message
Enter an alphanumeric value or a valid symbol for the following (see the online help for more information):
Detailed Description
The Subject line in the email contains invalid characters.
Recommended Response Action
Invalid character. Enter a valid value as mentioned in the online help.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0224

Message
Invalid e-mail description.
Detailed Description
A partial string used to construct a complete error message.
Recommended Response Action
Enter a valid email description.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0225

Message
Sending the test mail failed.
Detailed Description
Sending the test mail failed. This will prevent alert messages from being sent to this email address.
Recommended Response Action
Confirm that: 1. A valid SMTP server address is configred in the iDRAC. 2. The remote email server is configured properly to send and receive emails.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0226

Message
Send Failed: Request processing failed.
Detailed Description
Sending the test mail failed. This will prevent alert messages from being sent to this email address.
Recommended Response Action
Confirm that: 1. A valid SMTP server address is configred in the iDRAC. 2. The remote email server is configured properly to send and receive emails.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0227

Message
SD card is not detected: Insert an SD Card of size greater than 256MB.
Detailed Description
The SD card is not present, or communication with the SD card is lost. This could result in reduced functionality and capabilities.
Recommended Response Action
This error may occur because: 1. Make sure the SD card is seated correctly. 2. The SD card is invalid. Insert a valid SD card of size greater than 256MB and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0228

Message
SD Card is detected with an unrecognized format. Click Initialize to initialize the card.
Detailed Description
SD Card needs to be formatted to make it usable. The card must be initialized.
Recommended Response Action
Click Initialize to initialize the card and make it usable.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC023

Message
Unable to enable the User or set values for IPMILan, IPMISerial, or User Admin Privilege because the User Password is not configured.
Detailed Description
Unable to enable the User or set values for IPMILan, IPMISerial, or User Admin Privilege because the User Password is not configured.
Recommended Response Action
Set User Password before attempting to enable the other identified attributes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0230

Message
This operation erases all data in the SD Card. Do you want to continue?
Detailed Description
This message is displayed when a confirmation is required to initialize the vFlash SD Card.
Recommended Response Action
Press OK to initialize the SD Card. This will erase all data. If undesired press Cancel.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0231

Message
This operation erases all data in the partition. Do you want to continue?
Detailed Description
This message is displayed when a confirmation is required to format the vFlash SD Card partition.
Recommended Response Action
Press OK to initialize this partition of the SD Card. This action will erase all the data in this partition. If undesired press Cancel.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0235

Message
vFlash image upload timed out.
Detailed Description
When uploading an image to the vFlash partition, the operation is unresponsive, and has timed out.
Recommended Response Action
Try uploading the vFlash image again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0236

Message
Invalid image: Upload failed
Detailed Description
vFlash image upload failed because the image is not valid.
Recommended Response Action
Image may be corrupt. Try uploading a valid vFlash image.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0237

Message
An error occurred while uploading the vFlash image.
Detailed Description
A seperate message will provide more detail about this error which was detected while uploading the vFlash image.
Recommended Response Action
Try uploading the vFlash image again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0238

Message
vFlash is currently in-use by another process. Try again later.
Detailed Description
vFlash is unable to service the request at this time. Try again later.
Recommended Response Action
Try the operation after a few minutes.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0239

Message
SD Card is write-protected.
Detailed Description
The contents of a write protected SD Card cannot be modified.
Recommended Response Action
Make sure the SD Card is not write-protected before attempting to change its contents.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC024

Message
Unable to VLAN is Disabled so cannot set VLAN Priority because VLAN is Disabled.
Detailed Description
Unable to VLAN is Disabled so cannot set VLAN Priority because VLAN is Disabled.
Recommended Response Action
Enable VLAN to set VLAN Priority.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0240

Message
vFlash is disabled.
Detailed Description
vFlash needs to be enabled before attempting this operation.
Recommended Response Action
Enable vFlash before trying the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0241

Message
The specified size exceeds the maximum size of arg1 MB.
Arguments
arg1 = size
Detailed Description
SD Card does not have enough free space available.
Recommended Response Action
Delete existing data or insert a SD card of greater size and retry.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0242

Message
The selected partition does not exist.
Detailed Description
The vFlash partition does not exist. This may be due to another user deleting that partition.
Recommended Response Action
Refresh the Web GUI page to see the available partitions.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0243

Message
Partition failed: A partitioning conflict has occurred with another session.
Detailed Description
There was a conflict with a concurrent session. Another user may have logged inusing a separate browser or RACADM.
Recommended Response Action
There was a conflict with a concurrent session. Refresh the page to see the currently available options.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0244

Message
The partition label must be unique.
Detailed Description
This message is displayed when a duplicate vFlash partition name is entered.
Recommended Response Action
Enter a unique label name for the partition.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0245

Message
The partition is in-use by another process.
Detailed Description
The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed.
Recommended Response Action
Try the operation after a few minutes or with another partition. If the problem persists, reset iDRAC and repeat the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0246

Message
Partition is read-only.
Detailed Description
The contents of a read-only partition cannot be modified.
Recommended Response Action
Make sure the partition is writable before attempting to change its contents.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0247

Message
The partition is currently attached.
Detailed Description
This message is displayed when trying to format or download to an attached vFlash partition.
Recommended Response Action
Detach this partition and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0248

Message
This operation deletes the partition permanently. Do you want to continue?
Detailed Description
This message is displayed when trying to delete a vFlash partition.
Recommended Response Action
Press OK to delete this partition of the SD Card. This action will erase all the data in this partition. If undesired press Cancel.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0249

Message
One or more partitions are in-use by another process.
Detailed Description
The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed.
Recommended Response Action
Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC025

Message
Unable to set values for DNS1 or DNS2 attributes because DNS from DHCP is Enabled.
Detailed Description
Unable to set static values for DNS1 or DNS2 when DNS from DHCP is Enabled.
Recommended Response Action
Disable DNS from DHCP to set values for DNS1 or DNS2.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0250

Message
One or more partitions are read-only.
Detailed Description
The vFlash partitions are read-only. Therefore, the current operation cannot proceed.
Recommended Response Action
Make sure the partitions are writable before attempting to change their contents.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0251

Message
One or more partitions are currently attached.
Detailed Description
The vFlash partitions are attached. Therefore, the current operation cannot proceed.
Recommended Response Action
Detach the partitions and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0252

Message
One or more partitions are currently detached.
Detailed Description
The vFlash partitions are detached Therefore, the current operation cannot proceed.
Recommended Response Action
Attach the partitions and try again.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0253

Message
The IP Address is invalid. Expected range: [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Detailed Description
This error message is displayed to indicate that the IPv4 address does not conform to the required format.
Recommended Response Action
Enter a valid IP Address. Expected range: [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0254

Message
The Gateway Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Detailed Description
This error message is displayed to indicate that the IPv4 Gateway Address does not conform to the required format
Recommended Response Action
Enter a valid Gateway Address. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0255

Message
The Subnet Mask is invalid. Expected ranges are: 255.XXX.0.0 [Class A], 255.255.XXX.0 [Class B], 255.255.255.XXX [Class C], and XXX.0.0.0 [others], where XXX must be valid (0,128,192,224,240,248,252,254).
Detailed Description
This error message is displayed to indicate that the IPv4 Subnet Mask does not conform to the required format.
Recommended Response Action
Enter a valid Subnet Mask. Expected ranges are: 255.XXX.0.0 [Class A], 255.255.XXX.0 [Class B], 255.255.255.XXX [Class C], and XXX.0.0.0 [others], where XXX must be valid (0,128,192,224,240,248,252,254).
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0256

Message
The Preferred DNS Server Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Detailed Description
This error message is displayed to indicate that the Preferred DNS IPv4 address does not conform to the required format.
Recommended Response Action
Enter a valid Preferred DNS Server Address. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0257

Message
The Alternate DNS Server Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Detailed Description
This error message is displayed to indicate that the Alternate DNS IPv4 address does not conform to the required format.
Recommended Response Action
Enter a valid Alternate DNS Server Address. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0259

Message
Invalid IPv6 address.
Detailed Description
This error message is displayed to indicate that the IPv6 address does not conform to the required format.
Recommended Response Action
Enter a valid IPv6 address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC026

Message
Unable to set DNS Domain Name because "Domain Name From DHCP" is Enabled.
Detailed Description
Unable to set DNS Domain Name because "Domain Name From DHCP" is Enabled.
Recommended Response Action
Disable "Domain Name From DHCP" to set values for DNS Domain Name.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0260

Message
Invalid IPv6 prefix length. Expected range: 0-128.
Detailed Description
The specified IPv6 address prefix length is invalid.
Recommended Response Action
Enter a valid IPv6 prefix length. Expected range: 0-128.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0261

Message
Invalid IPv6 gateway address.
Detailed Description
This error message is displayed to indicate that the IPv6 gateway address does not conform to the required format.
Recommended Response Action
Enter a valid IPv6 gateway address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0262

Message
The Preferred IPv6 DNS Server Address is invalid.
Detailed Description
This error message is displayed to indicate that the Preferred IPv6 DNS Server address does not conform to the required format.
Recommended Response Action
Enter a valid Preferred IPv6 DNS server address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0263

Message
The Alternate IPv6 DNS Server Address is invalid.
Detailed Description
This error message is displayed to indicate that the Alternate IPv6 DNS Server address does not conform to the required format.
Recommended Response Action
Enter a valid Alternate IPv6 DNS server address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0265

Message
Specify the VLAN ID and VLAN Priority.
Detailed Description
If VLAN is enabled, specify the VLAN ID and VLAN Priority.
Recommended Response Action
Enter a VLAN ID and VLAN Priority.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0266

Message
Invalid VLAN ID. Expected range: 1-4094.
Detailed Description
Specify a valid VLAN ID.
Recommended Response Action
Enter a valid VLan ID. Expected range: 1-4094.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0267

Message
Invalid VLAN Priority. Expected range: 0-7.
Detailed Description
Specify a valid VLAN Priority.
Recommended Response Action
Enter a valid VLAN Priority. Expected range: 0-7.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0268

Message
NIC is disabled.
Detailed Description
The NIC is disabled. This may adversely affect the current operation, and might not allow subsequent GUI interactions to this NIC.
Recommended Response Action
Enable the NIC before performing the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0269

Message
The NIC MTU is invalid. Expected range: 576-1500 or 0x240-0x5DC.
Detailed Description
Specify a valid NIC MTU.
Recommended Response Action
Enter a valid NIC MTU. Expected range: 576-1500 or 0x240-0x5DC.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC027

Message
Unable to set values for Speed or Duplex because Auto Negotiation is Enabled.
Detailed Description
Unable to set static values for Speed or Duplex when the Auto Negotiation attribute is enabled.
Recommended Response Action
Disable Auto Negotiation in order to set values for Speed or Duplex.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0270

Message
IPv4 and IPv6 are disabled.
Detailed Description
This is a warning message that continuing this operation does not allow subsequent GUI interactions to this NIC.
Recommended Response Action
Enable IPv4 or IPv6 before continuing the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0271

Message
Continuing will lock user account.
Detailed Description
Locking the user account prevents them from gaining access to iDRAC.
Recommended Response Action
Press OK to lock this user account. This action will prevent future access for this user. If undesired press Cancel.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0272

Message
Disabling NIC will prevent the user from accessing the iDRAC remotely through Web GUI, Remote Racadm, Ssh, and Telnet. Local Racadm and serial interface will continue to work.
Detailed Description
If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled.
Recommended Response Action
Disable NIC only if remote access is undesired.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0273

Message
iDRAC access will be limited to running the Racadm utility on the local server or using the serial interface.
Detailed Description
If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled.
Recommended Response Action
Enable remote access to access iDRAC remotely.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0274

Message
See the iDRAC user documentation for more information on using the Racadm utility or the serial interface.
Detailed Description
If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled.
Recommended Response Action
See iDRAC user documentation for more information on using racadm.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0275

Message
Click OK to disable the NIC. Click Cancel to keep the setting unchanged.
Detailed Description
If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled.
Recommended Response Action
Disable NIC only if remote access is undesired.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0276

Message
To save the changes and update this page, click Apply.
Detailed Description
If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled.
Recommended Response Action
Click Apply to save changes.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0277

Message
Disabling IPv4 prevents access to iDRAC using an IPv4 address.
Detailed Description
This warning message appears when IPv4 is disabled.
Recommended Response Action
Use IPv6 network to access iDRAC remotely.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0278

Message
Disabling IPv6 prevents access to iDRAC using an IPv6 address.
Detailed Description
This warning message appears when IPv6 is disabled.
Recommended Response Action
Use IPv4 network to access iDRAC remotely.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0279

Message
Invalid Encryption Key. Expected format: 0 to 40 characters, even number of characters and no blank spaces are allowed.
Detailed Description
An invalid IPMI encryption key was entered.
Recommended Response Action
Enter a valid encryption key of up to 40 characters. Odd number of characters and blank spaces are not allowed.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC028

Message
Unable to Enable "DNS Domain Name From DHCP" or "DNS From DHCP" because DHCP is Disabled.
Detailed Description
The attributes "DNS Domain Name From DHCP" and "DNS From DHCP" are dependent on the attribute DHCP being Enabled. Currently DHCP is configured as Disabled.
Recommended Response Action
Set DHCP attribute to Enable to be able to Enable DNS Domain Name From DHCP or DNS From DHCP.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0280

Message
The IP Range Address is invalid. Expected range: 0.0.0.0 - 255.255.255.255.
Detailed Description
This error message is displayed to indicate that the IPv4 address does not conform to the required format.
Recommended Response Action
Enter a valid IP Range Address. Expected range: 0.0.0.0 - 255.255.255.255.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0281

Message
The IP Subnet Mask is invalid. Expected range: 0.0.0.0 - 255.255.255.255.
Detailed Description
This error message is displayed to indicate that the IP Subnet Mask does not conform to the required format.
Recommended Response Action
Enter a valid IP Subnet Mask. Expected range: 0.0.0.0 - 255.255.255.255.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0282

Message
IP Blocking Fail Count is invalid. Expected range: 2-16.
Detailed Description
This is the number of login failures attempted from an IP address before further login attempts are rejected from that address. The default value is 10.
Recommended Response Action
Enter a valid IP Blocking Fail Count. Expected range: 2-16.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0283

Message
IP Blocking Fail Window is invalid. Expected range: 10-65535.
Detailed Description
This is the time span (in seconds) within which IP Blocking Fail Count failures must occur to trigger the IP Blocking Penalty Time. The default value is 3600 seconds (1 hour).
Recommended Response Action
Enter a valid IP Blocking Fail Window. Expected range: 10-65535.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0284

Message
IP Blocking Fail Penalty Time is invalid. Expected range: 10-65535.
Detailed Description
This is the time span (in seconds) within which login attempts from an IP address with excessive failures are rejected. The default value is 3600 seconds (1 hour).
Recommended Response Action
Enter a valid IP Blocking Fail Penalty Time. Expected range: 10-65535.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0285

Message
User name cannot be empty.
Detailed Description
The user name cannot be empty when creating a user account.
Recommended Response Action
Enter a user name.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0286

Message
New Password and Confirm New Password fields cannot be empty.
Detailed Description
When creating a user account, the New Password and Confirm New Password fields cannot be empty.
Recommended Response Action
Enter valid passwords for New Password and Confirm New Password.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0288

Message
Invalid entry: Entry must be exclusively alphanumeric characters and valid symbols.
Detailed Description
All characters entered must be alphanumeric or valid symbols.
Recommended Response Action
Enter all alphanumeric characters and valid symbols.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0289

Message
Values in New Password and Confirm New Password fields do not match.
Detailed Description
When creating a user account, the same value must be entered for New Password and Confirm New Password.
Recommended Response Action
Enter the same values for both New Password and Confirm New Password.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC029

Message
Unable to complete the operation because necessary dependency values are not found in the input.
Detailed Description
The operation cannot be completed because necessary dependencay values are not found in the input.
Recommended Response Action
Refer to the Dell Lifecycle Controller Remote Services Quick Start Guide and Profile Documents available at the support site, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0290

Message
The user name cannot have spaces.
Detailed Description
The user name value does not accept spaces.
Recommended Response Action
Do not enter spaces in the user name. If desired, use underscores.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0291

Message
The user name cannot contain: /, \, @, ., or " (quotation mark).
Detailed Description
The user name value does not accept these characters.
Recommended Response Action
Do not enter /, \, @, ., or " (quotation mark) for user name.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0292

Message
A valid certificate is not loaded.
Detailed Description
This error is displayed when LDAP or Active Directory cannot find its certificate.
Recommended Response Action
Load a valid certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0293

Message
When certificate validation is enabled, a valid root Certificate Authority (CA) certificate must be uploaded. The CA certificate is used to verify the directory server SSL certificate.
Detailed Description
This error is displayed when LDAP or Active Directory cannot find an associated Certificate Authority (CA) certificate.
Recommended Response Action
Upload a valid root Certificate Authority (CA) certificate.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0294

Message
The Character Accumulate Interval value is invalid. Expected range: 1-255.
Detailed Description
The amount of time iDRAC waits before sending a partial Serial Over LAN (SOL) data packet. This parameter is specified in milliseconds. It is recommended to use 10 milliseconds for optimal performance.
Recommended Response Action
Enter a valid Character Accumulate Interval value. Expected range: 1-255.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0295

Message
The Character Send Threshold value is invalid. Expected range: 1-255.
Detailed Description
This is the number of characters per Serial Over LAN (SOL) data packet. When the number of characters accepted by iDRAC is equal to or greater than the Character Send Threshold value, iDRAC starts transmitting SOL data packets that contain the numbers of characters equal to or less than the Character Send Threshold value. If a packet contains fewer characters than this value, it is defined to be a partial SOL data packet. It is recommended to use 255 characters for optimal performance.
Recommended Response Action
Enter a valid Character Send Threshold value. Expected range: 1-255.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0297

Message
Specify a Domain Controller Address must be configured.
Detailed Description
The Domain Controller Address be specified for Active Directory configuration.
Recommended Response Action
Enter a valid Domain Controller Address.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0298

Message
Root Domain Name must be configured.
Detailed Description
A Root Domain Name must be specified for Active Directory configuration.
Recommended Response Action
Root Domain Name must be configured.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC030

Message
This attribute is dependent on a related attribute that has an incorrect value.
Detailed Description
This attribute is dependent on a related attribute that has an incorrect value. The related attribute is the parent in a parent-child value dependency relationship and has an affect on what values the child attribute can have.
Recommended Response Action
Refer to the Lifecycle Controller - Remote Services User Guide or the DCIM iDRAC Card Profile to determine the required values for the related attribute and retry the operation with the appropriate value.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0301

Message
Remote File Share connection is unavailable. Check the settings and try again.
Detailed Description
User will be unable to connect to Remote File Share.
Recommended Response Action
Make sure proper connectivity exists between the client and the remote file share before using this feature.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0302

Message
iDRAC Express does not support this feature.
Detailed Description
This error message is displayed when iDRAC does not have a valid Enterprise license.
Recommended Response Action
Upgrade to iDRAC Enterprise for supporting this feature.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0303

Message
Virtual Console is disabled or you do not have the Access Virtual Console privilege.
Detailed Description
This error message is displayed when Virtual Console feature is unavailable.
Recommended Response Action
Enable Virtual Console and ask the administrator to grant Access Virtual Console privilege.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0304

Message
Firmware update is terminated.
Detailed Description
Firmware update is terminated.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC031

Message
Unable to complete the operation because an incorrect username is entered.
Detailed Description
The operation cannot be completed because an incorrect username is entered.
Recommended Response Action
Enter a valid username and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC032

Message
Invalid value specified for DNS RAC name.
Detailed Description
The DNS RAC name specified is not valid.
Recommended Response Action
Retry operation with valid DNS RAC name.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC033

Message
Unable to enable attribute because IPv4 is Disabled.
Detailed Description
The specified attribute cannot be enabled since it depends on IPv4 to be enabled.
Recommended Response Action
Enable IPv4 and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC034

Message
Unable to create a job because the job queue is full.
Detailed Description
The job queue is full.
Recommended Response Action
Wait for existing jobs to run to completion or delete some jobs from the job queue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC035

Message
No pending configurations.
Detailed Description
There are no pending values for the any of the iDRAC attributes.
Recommended Response Action
Make sure there are pending values for the attributes that are targeted for configuration.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC036

Message
Attribute dependency failed.
Detailed Description
The value of the specified attribute is dependent on the value of another attribute. The current value dependency is invalid. The other attribute value must be changed before the specified attribute value can be set.
Recommended Response Action
Refer to the Lifecycle Controller-Remote Services documentation for the specified attribute dependency on another attribute value and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC037

Message
No pending configurations to delete.
Detailed Description
There are no pending configurations to delete.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC038

Message
Unable to perform the operation due to an unknown error in iDRAC.
Detailed Description
The operation did not complete successfully because of an unknown error in the iDRAC.
Recommended Response Action
Retry the action. If the issue persists, reset the iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC039

Message
Invalid parameter value for arg1 .
Arguments
arg1 = parameter
Detailed Description
The value provided for the specified parameter is invalid.
Recommended Response Action
Verify the value for the specified parameter. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC040

Message
Missing parameters arg1 .
Arguments
arg1 = parameters
Detailed Description
One or more required parameters needed for the method invoked in the operation are missing.
Recommended Response Action
Verify that all required parameters are provided. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0400

Message
iDRAC memory low.
Detailed Description
iDRAC is running low on memory.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0401

Message
idracmonitor: arg1
Arguments
arg1 = error string
Detailed Description
Critical error from iDRAC service recovery program.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC041

Message
The set operation on the event filters failed.
Detailed Description
The event filters set operation did not complete successfully due to invalid input parameters.
Recommended Response Action
Verify the specified input parameters and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC042

Message
Invalid number of input parameters.
Detailed Description
The number of input parameters provided is not valid to perform the operation.
Recommended Response Action
Verify that all required parameters are provided. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC043

Message
Unable to update some event filter settings.
Detailed Description
Some event filter settings were not updated due to problems encountered processing the input parameters.
Recommended Response Action
Verify the input parameters provided and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC044

Message
Unable to update some event filter settings.
Detailed Description
Some event filter settings were not updated due to problems encountered processing the input parameters.
Recommended Response Action
Verify the input parameters provided and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC045

Message
Event filter does not exist for input parameter combination.
Detailed Description
The combination of input parameters provided did not match any event filters.
Recommended Response Action
Verify the combination of input parameters and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC046

Message
Unsupported event notification for the event filter specified.
Detailed Description
The event notfication selected is not supported for the event filter specified.
Recommended Response Action
Refer to the iDRAC User Guide and Lifecycle Controller documentation and retry the operation with a valid event notification selection on the specified filter.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC047

Message
Unsupported event action for the specified event filter.
Detailed Description
The event action selected is not supported for the event filter specified.
Recommended Response Action
Refer to the iDRAC User Guide and Lifecycle Controller documentation and retry the operation with a valid event action selection on the specified filter.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC048

Message
The operation was successful.
Detailed Description
The operation completed successfully.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC049

Message
Resource allocation failure.
Detailed Description
The operation did not complete successfully because of lack of memory or file space in the iDRAC.
Recommended Response Action
Reset the iDRAC and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC050

Message
Invalid country code.
Detailed Description
The country code is not entered in the correct format or does not exist. Refer to ISO 3166 for the correct country code format.
Recommended Response Action
Enter country code in the correct format as defined in ISO 3166. For example, United States = US.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0500

Message
There are no batteries to be displayed.
Detailed Description
Batteries cannot be displayed. This error may occur if the host system is powered off or there is a bad or disconnected cable for batteries connected to the controller.
Recommended Response Action
1. Check if the host system is powered off or shutdown. 2. Verify that the batteries are connected properly.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0501

Message
There are no physical disks to be displayed.
Detailed Description
Physical disks cannot be displayed. This error may occur if the host system is powered off or the physical disks are removed. This may result in communication loss while retrieving controller data.
Recommended Response Action
1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are inserted into the enclosure or attached to the backplane. 3. There are no out-of-band capable controllers detected.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0502

Message
There are no virtual disks to be displayed.
Detailed Description
Virtual disks cannot be displayed. This error may occur if the host system is powered off or there are no virtual disks created.
Recommended Response Action
1. Check if the host system is powered off or shutdown. 2. Check if virtual disks are created.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0503

Message
There are no out-of-band capable controllers to be displayed.
Detailed Description
Out-of-band controllers cannot be displayed. This error may occur if the host system is powered off, or controllers are removed or disconnected.
Recommended Response Action
Check if the host system is powered off or shutdown.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0504

Message
There are no enclosures to be displayed.
Detailed Description
Enclosures cannot be displayed. This error may occur if the host system is powered off, there is no enclosure connected to the controller, or there is a bad or disconnected adapter cable for the enclosure.
Recommended Response Action
1. Check if the host system is ON. 2. Check if the Storage Enclosure is ON. 3. Verify that the adapter cables are properly connected and there are no bent pins.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0505

Message
There are no devices to be displayed.
Detailed Description
Devices are not displayed. This error may occur because these components are removed or disconnected.
Recommended Response Action
1. Check if the host system is ON. 2. Check if the Storage Enclosure is ON. 3. Verify that the adapter cables are properly connected and there are no bent pins.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0506

Message
You do not have privileges to perform this operation.
Detailed Description
This error occurs when the user tries to access a program or function that is beyond user granted privileges.
Recommended Response Action
Contact the system administrator to perform the operation or grant the required privileges.
Category
Storage (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0507

Message
Unable to find the requested resource.
Detailed Description
The requested information cannot be displayed, because the system did not find any matching resource. This occurs because the system is turned off, resource is not present, or the resource is removed or deleted. For example, resources such as physicals disks, vFlash SD card, SSL certificate or custom signing certificate.
Recommended Response Action
Do one of the following and retry the operation: 1) Turn on the system. 2) Make the resource available.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0508

Message
An unexpected error occurred.
Detailed Description
The server encountered an unexpected condition. This may be due to invalid JavaScript Object Notation.
Recommended Response Action
Wait for few minutes and refresh the page. If the problem persists, contact service provider.
Category
Storage (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0509

Message
The server is temporarily unavailable. Try again after sometime
Detailed Description
The server is currently unable to handle the request due to temporary overloading or server maintenance.
Recommended Response Action
Wait for few minutes and refresh the page. If the issue persists, contact service provider.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC051

Message
Unsupported parameter name arg1 .
Arguments
arg1 = parameter name
Detailed Description
The parameter name is not supported.
Recommended Response Action
Remove the unsupported parameter and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0510

Message
There are no events to be displayed.
Detailed Description
This error occurs if Lifecycle log events have not occurred recently.
Recommended Response Action
No response action is required.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0511

Message
There are no physical disks to be displayed.
Detailed Description
Physical disks cannot be displayed. This error may occur if the host system is powered off, physical disks are removed, or incorrect filters are applied.
Recommended Response Action
1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are inserted into the enclosure or attached to the backplane. 3. Check if correct filters are applied. 4. Check that the Storage Enclosure is on. 5. verify that the adapter cables are properly connected and there are no bent pins.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0512

Message
There are no virtual disks to be displayed.
Detailed Description
Virtual disks cannot be displayed. This error may occur if the host system is powered off, no virtual disks were created, or incorrect filters are applied.
Recommended Response Action
1. Check if the host system is ON. 2. Check if virtual disks are created. 3. Check if correct filters are applied. 4. Check if the Storage Enclosure is ON. 5. Verify that the adapter cables are properly connected and there are no bent pins.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0513

Message
There are no virtual disks to be displayed.
Detailed Description
There are no virtual disks to be displayed. There may be no virtual disks created, the controller(s) may not be in RAID mode, or there may be pending creation or deletion jobs that have not completed.
Recommended Response Action
Check the following: 1) Check if the server is turned off. If the server is turned off, turn it on and wait until POST completes. 2) If no virtual disks are created, to start the virtual disk creation process, click #{create_virtualdisk_link}. 3) If create virtual disk operation(s) are in a pending state, complete the creation process. To complete the virtual disk(s) creation, go to the Pendng Operations page and create a configuration job on the appropriate controller. 4) If delete virtual disk operation(s) are in pending state, then cancel the operation. To cancel delete virtual disk pending operation(s), go to the Pending Operations page and delete all pending operation(s) on the appropriate controller. 5) If the Controller(s) are in HBA mode, switch the controller(s) to RAID mode. To switch controller(s) to RAID mode using the F2 System Setup utility, go to Device Settings > RAID Controller > Controller Management > Advanced Controller Management > Switch to RAID mode.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0514

Message
Unable to create virtual disk(s) on the selected controller.
Detailed Description
Virtual disk(s) cannot be created because of one or more reasons identified in the Recommended Response Action.
Recommended Response Action
Check the following: 1) If no physical disk drives are available for virtual disk (VD) creation, install additional physical disk drives. 2) If the maximum number of VDs that can be created on the controller has been reached, a new VD cannot be created until an existing VD is deleted. 3) If the maximum number of VDs supported by drive group has been created, a new VD cannot be created until an existing VD is deleted from the selected drive group. 4) If the physical disk drive(s) are in non-RAID mode, convert them to RAID mode by pressing Ctrl+R while restarting the server, and then select the required controller. Press F2 and select the Convert to RAID capable option, and then complete the operation. 5) If a job is currently running or scheduled on the selected controller, the job must be completed or deleted before attempting a new operation. Status of the scheduled job can be viewed and managed on the Job Queue page on iDRAC. Click Job Queue link to view the status of the scheduled jobs.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0516

Message
Converting physical disk drives to RAID-compatible will overwrite any OS-created RAID arrays.
Detailed Description
Converting physical disk drives to RAID-compatible will overwrite any OS-created RAID arrays.
Recommended Response Action
Make sure that there are no OS-configured RAID arrays, and then click OK.
Category
Storage (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC052

Message
Unable to create a configuration job because an existing configuration job is already in progress.
Detailed Description
Unable to create a configuration job because an existing configuration job is already in progress. Only one configuration job for a component can run or can be processed at any time.
Recommended Response Action
Retry the operation after the existing configuration job is complete, or cancel the existing configuration job and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC053

Message
OS to iDRAC pass-through is disabled.
Detailed Description
One or more attributes being set are dependent on OS to iDRAC pass-through being enabled.
Recommended Response Action
Enable OS to iDRAC pass-through and retry the previous command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC054

Message
User account attributes cannot be reset to default values due to an internal error.
Detailed Description
The user account attributes cannot be reset to default values due to an internal error.
Recommended Response Action
Make sure the configuration XML file contains valid values for user account attributes and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC055

Message
User name cannot be cleared because the user account is enabled in the input configuration XML file.
Detailed Description
The user name for the user account cannot be cleared because the user account is enabled in the configuration XML file.
Recommended Response Action
Retry the operation after disabling the user account in the configuration XML file.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC056

Message
Unable to set the Authentication Protocol attribute to None because the Privacy Protocol attribute is enabled for user ID: arg1
Arguments
arg1 = user ID
Detailed Description
The Authentication Protocol attribute for the user account identified in the message cannot be disabled because the Privacy Protocol attribute is enabled. The Privacy Protocol for the user account is not set to None.
Recommended Response Action
Disable the Privacy Protocol attribute for the identified user ID account by setting the value to None, and retry the operation to set Authentication Protocol attribute to None.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0560

Message
RAC Software Initialization Error
Detailed Description
RAC Software Initialization error. Monitoring data will not be available for PERC and Network Cards
Recommended Response Action
Contact Dell Tech Support
Category
System Health (RAC = RAC Event)
Severity
Severity 3 (Informational)
Trap/EventID
2531
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC          

RAC0561

Message
iDRAC to CMC communication link is not functioning for agent free monitoring of chassis PCIe slots.
Detailed Description
iDRAC lost connection with CMC proxy component that enables agent free monitoring of PCIe slots. Agent free monitoring will not be supported for Chassis PCIe slots while this connection is not functioning.
Recommended Response Action
Do the following: 1) Check the Lifecycle Log for the subsequent RAC0562 communications restored message that will indicate the link was re-established automatically. 2) If there is no subsequent RAC0562 message in the Lifecycle Log, restart the iDRAC. The iDRAC can be restarted by using the RACADM command line utility and entering "racadm racreset". 3) After the iDRAC has restarted, if the communications link is still not functioning, restart the CMC and check the Lifecycle Log for this link error after the CMC has restarted. 4) If the issue persists, contact your service provider.
Category
System Health (RAC = RAC Event)
Severity
Severity 3 (Informational)
Trap/EventID
2531
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RAC0562

Message
iDRAC-CMC communication restored for agent free monitoring of chassis PCIe slots.
Detailed Description
iDRAC automatically restored connection with CMC proxy component. Agent free Monitoring will now be supported for Chassis PCIe slots.
Recommended Response Action
No response action is required.
Category
System Health (RAC = RAC Event)
Severity
Severity 3 (Informational)
Trap/EventID
2531
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RAC057

Message
Unable to set Privacy Protocol to an enabled state because the Authentication Protocol attribute is set to None for the user ID: arg1
Arguments
arg1 = user ID
Detailed Description
The Privacy Protocol for the user cannot be enabled because the Authentication protocol is disabled.
Recommended Response Action
Enable the Authentication Protocol attribute for the identified user ID account, and retry the operation to set the Privacy Protocol to an enabled state.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC058

Message
AttributeValue is not unique for AttributeName arg1 .
Arguments
arg1 = attribute name
Detailed Description
The value provided for the specified attribute is not unique. For example, the user name for a user account must be unique.
Recommended Response Action
Provide a unique value for the specified attribute. For more information about the component being managed, see the DCIM Profile documentation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC059

Message
Unable to configure iDRAC time because Network Time Protocol (NTP) is enabled.
Detailed Description
When the Network Time Protocol (NTP) feature is enabled, the iDRAC will get time from the configured NTP server. Directly configuration of the iDRAC time is disabled when NTP is enabled.
Recommended Response Action
Disable Network Time Protocol (NTP) and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC060

Message
Unable to set the attribute because OpenManage Server Administrator (OMSA) is installed on the server arg1
Arguments
arg1 = attribute name
Detailed Description
The attribute identified in the message could not be set, because certain features cannot be enabled when OMSA is installed on the server.
Recommended Response Action
Uninstall OMSA, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0600

Message
Unable to retrieve the temperature information.
Detailed Description
Temperature information cannot be displayed. This error may occur if the server is powered off.
Recommended Response Action
Power on the server. If the server is already powered on, wait for a few minutes and refresh the page. If the problem persists, contact service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0601

Message
Unable to retrieve alert recurrence information.
Detailed Description
The server encountered an unexpected condition. This may be due to invalid JavaScript Object Notation.
Recommended Response Action
Wait for few minutes and refresh the page. If the problem persists, contact service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0602

Message
Invalid value for alert recurrence.
Detailed Description
The value for alert recurrence must be within the range 0-365.
Recommended Response Action
Enter a value between 0-365.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0603

Message
Updating Job Queue. Status of the update jobs can be viewed and managed within the Job Queue page.
Detailed Description
The Job Queue is updated with the selected update jobs. The status of the update jobs can be viewed and managed within the Job Queue page.
Recommended Response Action
Click Job Queue button to view the status of the update jobs.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0604

Message
System inventory may not be up-to-date because Collect System Inventory On Restart (CSIOR) is disabled.
Detailed Description
The system inventory may not be up-to-date because the Collect System Inventory On Restart (CSIOR) feature is disabled. The CSIOR feature retrieves detailed system inventory information during system startup and stores this information on iDRAC.
Recommended Response Action
Enable CSIOR, restart the system and retry the operation. To enable CSIOR, press F2 (System Setup) during system startup, navigate to iDRAC Settings >Lifecycle Controller, and select the Enabled option for Collect System Inventory on Restart.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0605

Message
There are no jobs to be displayed.
Detailed Description
There are no jobs to be displayed.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0606

Message
The network connection test operation was successful.
Detailed Description
The selected network connection test operation was successsful.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0607

Message
Unable to perform OS to iDRAC Pass-Through with the current system configuration.
Detailed Description
The integrated NICs in the system do not support OS to iDRAC Pass-Through.
Recommended Response Action
Make sure the integrated NICs are enabled from BIOS setup and support OS to iDRAC Pass-Through, then retry the operation. To access BIOS setup, press F2 during system startup. For more information about OS to iDRAC Pass-Through, see iDRAC7 Users Guide.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0608

Message
The iDRAC will restart when the iDRAC firmware update is complete. All current user sessions will be closed.
Detailed Description
The message appears in Job Queue page when the iDRAC firmware update job status is downloading. Communication to the iDRAC will be lost when the iDRAC restarts to complete the firmware update.
Recommended Response Action
Reconnect iDRAC communications session after iDRAC is restarted. The iDRAC will be ready for login once the restart is complete.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0609

Message
The job arg1 has been successfully added to the job queue.
Arguments
arg1 = import or export job ID
Detailed Description
The import or export system configuration operation with the job ID indicated in the message was successfully added to the Job Queue.
Recommended Response Action
No response action is required. The status of jobs can be viewed on the Job Queue page.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC061

Message
Unable to set the IPMI Watchdog because the OS Watchdog is already enabled..
Detailed Description
The IPMI Watchdog can not be enabled at the same time as the OS Watchdog.
Recommended Response Action
Disable the OS Watchdog before enabling IPMI Watchdog.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0610

Message
The passphrase and confirm passphrase values entered do not match.
Detailed Description
Different values were entered for passpharse and confirm passpharse field.
Recommended Response Action
Values entered in passphrase and confirm passphrase fields must be the same.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0611

Message
IP Address cannot be blank.
Detailed Description
The IP address cannot be blank for import or export of system configuration profile operation.
Recommended Response Action
Enter a valid IP Address for network location.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0612

Message
Cancelling the firmware update operation will delete all the uploaded firmware files. Do you want to continue?
Detailed Description
Cancelling the firmware update operation will cancel all firmware updates selected and delete all uploaded firmware files.
Recommended Response Action
Select Yes to cancel the firmware update operation and delete all uploaded firmware files. Select No to dismiss the message and continue the firmware update operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0613

Message
The uploaded file is invalid.
Detailed Description
An internal error occurred because of an invalid file.
Recommended Response Action
Make sure to upload the required file in the correct format and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0614

Message
Incorrect password for PKCS#12 file.
Detailed Description
The specified password was incorrect for the PKCS#12 file.
Recommended Response Action
Make sure to use the correct password for the PKCS#12 file. If the PKCS#12 file is encrypted with a password, add it in required password box. Leave the password box empty if the file was not encrypted with a password.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0615

Message
Invalid PKCS#12 file.
Detailed Description
The contents of the PKCS12 file was not valid because one of the following: 1) Not a valid PKCS#12 file, 2) Not a valid pfx file or 3) Did not contain a valid key.
Recommended Response Action
Make sure to upload the file in PKCS#12 format. OpenSSL can be used to validate a PKCS#12 file.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0616

Message
Error while extracting custom signing certificate and private key from the PKCS#12 file.
Detailed Description
iDRAC was unable to continue with the operation after the PKCS#12 file was uploaded, because it is not able to extract the custom signing certificate and private key.
Recommended Response Action
Make sure to upload the PKCS#12 file that contains a valid custom signing certificate and private key.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0617

Message
An error was encountered while generating new SSL Certificate.
Detailed Description
An error occurred while generating new iDRAC SSL Certificate or signing it with new custom signing certificate.
Recommended Response Action
Make sure to upload an PKCS#12 file that contains a valid custom signing certificate and private key, then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0618

Message
Incorrect data entered.
Detailed Description
The data entered caused an error while processing the request.
Recommended Response Action
Make sure to enter the correct data and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0619

Message
The iDRAC firmware rollback will cause an iDRAC restart and all current user sessions will be closed.
Detailed Description
The message appears in Firmware Rollback page when the iDRAC firmware rollback action completed successfully.
Recommended Response Action
Reconnect iDRAC communications sessions after iDRAC is restarted. The iDRAC will be ready for login once the restart is complete.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC062

Message
Unable to set the WatchdogResetTime because the IPMI Watchdog state is disabled.
Detailed Description
The WatchdogResetTime can not be set if the IPMI Watchdog state is disabled.
Recommended Response Action
Enable the IPMI Watchdog state and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0620

Message
Lifecycle Controller is unable to delete the selected jobs.
Detailed Description
Lifecycle Controller is currently busy performing tasks. The selected jobs cannot be deleted until the following: 1) The Lifecycle Controller tasks are completed. 2) The system completes all the Power-on-Self-test (POST) operations.
Recommended Response Action
Wait until Lifecycle Controller completes the current tasks and the system completes Power-on Self-test (POST).
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0621

Message
Successfully completed the iDRAC firmware update. All current user sessions will be closed.
Detailed Description
The message appears in Job Queue page when the iDRAC firmware update job status is completed. Communication to the iDRAC will be lost .
Recommended Response Action
The iDRAC will be ready for login once the restart is complete.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0622

Message
An invalid certificate file is uploaded.
Detailed Description
The certificate file is invalid for one of the following reasons: 1) CA Certificate is corrupted, expired, or does not have signing privileges. 2) CA private key does not matchi with CA Certificate being uploaded.
Recommended Response Action
Make sure the CA certificate and private key are correct and retry the operation. The certificate can be validated using the OpenSSL tools.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0623

Message
The firmware versions on all the components of this server are up-to-date.
Detailed Description
A firmware update is not required for the components on the server, because current firmware versions are the latest available in the repository.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0624

Message
Unable to find the requested job type or ID.
Detailed Description
The requested operation could not be completed, because an incorrect job type or job ID is entered.
Recommended Response Action
Enter the correct job type or ID, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0625

Message
Unable to schedule, because the requested job schedule type is not enabled.
Detailed Description
The requested job cannot be scheduled, because job schedule types such as Automatic Backup or Automatic Update is not enabled.
Recommended Response Action
Enable the correct job schedule type, and then retry the operation. For example, to enable the Automatic Backup feature, select the Enable Automatic Backup option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0626

Message
Unable to schedule, because an invalid schedule parameter is entered.
Detailed Description
The job cannot be scheduled, because all or some of the schedule parameters entered are incorrect.
Recommended Response Action
Enter correct input schedule parameters and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0627

Message
Unable to schedule, because the requested recurrent Automatic Backup job is already scheduled.
Detailed Description
The job cannot be scheduled, because the requested recurrent Automatic Backup job is already scheduled.
Recommended Response Action
Delete the current scheduled job, and then retry to create a new Automatic Backup job with a new schedule.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0628

Message
Unable to schedule, because the requested recurrent Automatic Update job is already scheduled.
Detailed Description
The job cannot be scheduled, because the requested recurrent Automatic Update job is already scheduled.
Recommended Response Action
Delete the current scheduled job, and then retry to create a new Automatic Update job with a new schedule.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0629

Message
Unable to schedule, because an invalid job type is entered.
Detailed Description
The job cannot be scheduled, because the requested job type is not supported.
Recommended Response Action
Enter a correct job type, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC063

Message
The string length of the provided value for arg1 is inappropriate.
Arguments
arg1 = attribute name
Detailed Description
The string length of the entered value for the attribute identified in the message may be less than the minimum length or greater than the maximum length allowed.
Recommended Response Action
Make sure that the string length is correct and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0630

Message
Unable to schedule, because an invalid network file share type is entered.
Detailed Description
The job cannot be scheduled, because the requested network file share type is not supported.
Recommended Response Action
Enter a correct network file share type, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0631

Message
Unable to access the network file share, because an invalid network file share name is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid network file share name is entered.
Recommended Response Action
Enter a valid network file share name, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0632

Message
Unable to access the network file share, because an invalid network file share hostname or IP address is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid hostname or IP address is entered.
Recommended Response Action
Enter a valid network file share hostname or IP address, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0633

Message
Unable to access the network file share, because an invalid network share password is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid password is entered.
Recommended Response Action
Enter a valid network file share password, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0634

Message
Unable to access the network file share, because an invalid network file share username is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid username is entered.
Recommended Response Action
Enter a valid network file share username, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0635

Message
Unable to access the network file share, because an invalid domain name is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid domain name is entered.
Recommended Response Action
Enter a valid domain name, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0636

Message
Unable to access the network file share, because an invalid proxy password is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid proxy password is entered.
Recommended Response Action
Enter a valid proxy password, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0637

Message
Unable to access the network file share, because an invalid proxy user name is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid proxy user name is entered.
Recommended Response Action
Enter a valid proxy user name, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0638

Message
Unable to access the network file share, because an invalid proxy host name or IP address is entered.
Detailed Description
The requested network file share cannot be accessed, because an invalid proxy host name or IP address is entered.
Recommended Response Action
Enter a valid proxy host name or IP address, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0639

Message
Unable to schedule, because an invalid minute value is entered.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for minute while scheduling a job.
Recommended Response Action
Enter a correct value from 0 to 59, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC064

Message
iDRAC was successfully reset.
Detailed Description
iDRAC was successfully reset.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0640

Message
Unable to schedcule, because an invalid hour value is entered.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for hour while scheduling a job.
Recommended Response Action
Enter a correct value from 0 to 23, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0641

Message
Unable to schedcule, because an invalid timevalue is entered.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for time while scheduling a job.
Recommended Response Action
Enter a correct value in the HH:MM format, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0642

Message
Unable to schedule, because an invalid value is entered for the day of a month.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for day of a month while scheduling a job.
Recommended Response Action
Enter a correct numerical value in the following format: Day [1 to 31] of every [1 to 12] month(s). For example, Day 4 of every 11 months. Retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0643

Message
Unable to schedule, because an invalid monthvalue is entered.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for month while scheduling a job.
Recommended Response Action
Enter a correct numerical value in the following format: Day [1 to 31] of every [1 to 12] month(s). For example, Day 4 of every 11 months. Retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0644

Message
Unable to schedule, because an invalid ear value is entered.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for year, while scheduling a job.
Recommended Response Action
Enter a correct value, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0645

Message
Unable to schedule, because an invalid value is entered for the recurrence frequency.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for recurrence frequency while scheduling a job.
Recommended Response Action
Enter a correct value, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0646

Message
Unable to schedule, because an invalid value is entered for the day of the week.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for day of the week while scheduling a job.
Recommended Response Action
Enter a correct value, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0647

Message
Unable to schedule, because an invalid value is entered for the week of the month.
Detailed Description
The job could not be successfully scheduled, because an invalid value is entered for week of the month while scheduling a job.
Recommended Response Action
Enter a correct value from 1 to 4, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0648

Message
Unable to process the request.
Detailed Description
The request cannot be processed, because the length of string entered for one of the input parameter is more than the specified length.
Recommended Response Action
Enter a string not more than 4095 characters in length, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0649

Message
Unable to process the request.
Detailed Description
Unable to process the request, because data is not entered or not selected in one or more mandatory fields.
Recommended Response Action
Make sure to enter or select data in all the mandatory fields, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC065

Message
iDRAC reset operation was not successful.
Detailed Description
The iDRAC reset operation was not successful. This may be due to IPMI communications issues.
Recommended Response Action
Do the following: 1) Retry the operation. 2) If the issue persists, remove AC input power from the server and re-apply AC power to the server and retry the operation. 3) If the issue constinues to persist, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0654

Message
No operations can be performed on the iDRAC Service Module.
Detailed Description
Unable to perform operations on the iDRAC Service Module (iSM) because the iSM is not installed on the server operating system. All fields in the iDRAC GUI iSM page are disabled.
Recommended Response Action
Make sure that the iDRAC Service Module is installed on the server operating system, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0655

Message
The Replicate Lifecycle Controller Log in OS Log and Auto System Recovery Action features are disabled in the iDRAC Service Module because the OpenManage Server Administrator is installed on the server operating system.
Detailed Description
The Replicate Lifecycle Controller Log in OS Log and Auto System Recovery Action features are disabled in the iDRAC Service Module because the OpenManage Server Administrator is installed on the server operating system.
Recommended Response Action
None
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0656

Message
Are you sure you want to disable the iDRAC Service Module on the server operating system?
Detailed Description
The iDRAC Service Module (iSM) service cannot be started by just enabling in iDRAC web interface because the service has to also be manually restarted on the server operating system.
Recommended Response Action
To re-enable the iDRAC Service Module (iSM), do the following: 1) Enable the iSM in the iDRAC web interface, 2) Start the iSM service on the server operating system.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0657

Message
The file name field must not be blank.
Detailed Description
The file name cannot be blank when performing the Backup Server Profile operation.
Recommended Response Action
Enter an appropriate file name, and then retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0658

Message
The iDRAC Service Module service can now be manually started on the server operating system.
Detailed Description
The iDRAC Service Module service can now be started on the server operating system. This service needs to be started manually on the server operating system.
Recommended Response Action
None
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0659

Message
Unable to perform the storage configuration operation(s) on arg1 because a job is currently pending or is running on the adapter.
Arguments
arg1 = adapter name
Detailed Description
The storage configuration operation(s) cannot be performed on the adapter identified in the message because a job is currently pending or is running on the adapter.
Recommended Response Action
Wait for the job to completely run, or delete the job, and then retry the operation.To view the status of the scheduled jobs, go to the Job Queue page of iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC066

Message
iDRAC is successfully reset to factory-default properties.
Detailed Description
iDRAC was successfully reset to factory-default properties.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0660

Message
Unable to access the specified file server location.
Detailed Description
The file server cannot be accessed because of incorrect credentials.
Recommended Response Action
Check the file server credentials and retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0661

Message
Storage configuration operation - #(operation) is pending on the selected #{devicetype} : #{devicename}.
Detailed Description
Various storage configuration operations can be performed on different devices such as physical disks, virtual disks, controllers, or enclosures. The operations are applied to the device by creating a configuration job on the associated controller.
Recommended Response Action
To complete the storage configuration operation, create a storage configuration job with the necessary scheduling.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0662

Message
The Clear Foreign Configuration operation will delete the foreign virtual disk information from the controllers associated physical disk drives. Clearing will remove metadata associated with the virtual disks, making the physical disk drives available for creating new virtual disks. To remove foreign data, perform an initialization operation.
Detailed Description
Clear foreign configuration will delete the foreign virtual disk information from the controllers associated physical disk drives. Clearing will remove metadata associated with the virtual disks, making the physical disk drives available for creating new virtual disks. To remove foreign data, perform an initialization operation.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0663

Message
Resetting the selected PERC controllers configuration will delete all the virtual disks (VDs) and unassign hot-spares from the associated controller.
Detailed Description
Resetting the selected PERC controllers configuration will delete all the virtual disks (VDs) and unassign hot-spares from the associated controller.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0664

Message
Exporting the RAID Controller Log will take less than arg1 minutes. Job ID: #{jobID} is created for the RAID Controller Log Export operation.
Arguments
arg1 = number of minutes
Detailed Description
Exporting the RAID Controller Log will take less than the number of minutes identified in the message. The job identified in the message is created for the RAID Controller Log Export operation.
Recommended Response Action
To check the progress of the job click the Job Queue button.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0665

Message
RAID Controller Log data is being collected. This operation will take less than arg1 minutes.
Arguments
arg1 = number of minutes
Detailed Description
RAID Controller Log data is being collected. This operation will take less than the number of minutes identified in the message.
Recommended Response Action
Do not log off from the application until the log data collection process is completed.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0666

Message
A RAID Controller Log is created.
Detailed Description
A RAID Controller Log is created.
Recommended Response Action
To export the Log report, click OK. To delete the report, click Cancel.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0667

Message
This setting will be applied after the server has been turned off and turned on again. This may result in loss of configuration and/or access to physical disk drive(s).
Detailed Description
This setting will be applied after the server has been turned off and turned on again. This may result in loss of configuration and/or access physical disk drive(s) or virtual disk(s) being marked offline. This may also result in some disk(s) being identified as foreign disks. Foreign physical disk drive(s) or virtual disk(s) can be imported or cleared.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0668

Message
This setting will be applied during the next server restart. If the setting is not compatible with the RAID Controller, then LED status indicators on all the associated hard disk drives (HDDs) stop functioning.
Detailed Description
This setting will be applied during the next server restart. If the setting is not compatible with the RAID Controller, then LED status indicators on all the associated hard disk drives (HDDs) stop functioning.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0669

Message
Initializing the virtual disk will permanently delete data from the virtual disk.
Detailed Description
Initializing the virtual disk will permanently delete data from the virtual disk.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC067

Message
iDRAC reset to factory defaults operation was not successful.
Detailed Description
iDRAC reset to factory defaults operation was not successful. This may be due to IPMI communications issues.
Recommended Response Action
Do the following: 1) Retry the operation. 2) If the issue persists, remove AC input power from the server and re-apply AC power to the server and retry the operation. 3) If the issue constinues to persist, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0670

Message
Deleting the virtual disk will remove the virtual disk from the controllers configuration.
Detailed Description
Deleting the virtual disk will remove the virtual disk from the controllers configuration. If the specified virtual disk is a boot device, the server will not boot unless another boot device is selected in BIOS.
Recommended Response Action
If the specified virtual disk is a boot device, the server will not boot. Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0671

Message
Going out of this page will not save the operations or configuration settings that were selected.
Detailed Description
Going out of this page will not save the operations or configuration settings that were selected.
Recommended Response Action
Press OK to continue. Press Cancel to continue working on the page.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0673

Message
OS Collector must be run on the server OS in order to export OS and Application Data. A virtual USB device labeled DRACRW has appeared in the server OS. This device contains the OS Collector utility, go to the Server OS and run the version of the utility appropriate to the OS type. After the OS Collector utility execution has completed, return to this page to finish exporting the Technical Support Report (TSR).
Detailed Description
To export operating system (OS) and application data, the OS Collector utility must be run on the server OS. A virtual USB device labeled DRACRW has appeared in the server OS. After the OS Collector utility execution has completed, return to this page to complete exporting the Tech Support Report (TSR).
Recommended Response Action
Invoke the OS Collector utility in the OS and wait for execution completion. Then return to this page to complete exporting the Technical Support Report (TSR).
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0674

Message
Export Report will create a zip file of XML and text-based logs intended for Dell Technical Support assistance with troubleshooting system issues. Choose Advanced Export Options to specify optional report settings and actions.
Detailed Description
Export Report will create a zip file of XML and text-based logs intended for Dell Technical Support assistance with troubleshooting system issues. Choose Advanced Export Options to specify optional report settings and actions.
Recommended Response Action
No response action is requried.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0675

Message
Results are not available for the search criterion entered.
Detailed Description
Results are not available for the search criterion entered.
Recommended Response Action
Enter another criterion and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC0676

Message
Unable to assign physical disk drives as global hotspare(s).
Detailed Description
Unable to assign physical disk drives as global hotspare(s). This may be because there are no disk drives available in a ready state or there are no virtual disks present.
Recommended Response Action
Do one of the following and retry the operation: 1) If there are no disk drives available in ready state, insert additional disk drives and make sure the drives are in ready state. 2) If no virtual disks are present, click <create virtualdisk link> and create at least one virtual disk. 3) If the physical disk drive(s) are in non-RAID mode, convert them to RAID mode by pressing Ctrl+R while restarting the server, and then select the required controller. Press F2 and select the Convert to RAID capable option, and then complete the operation.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0677

Message
No physical disk drives in ready state, no virtual disks are created, and no PCIe SSD drives are available to perform operations on.
Detailed Description
No physical disk drives in ready state, virtual disks, or PCIe SSD drives are available to perform operations on.
Recommended Response Action
Do one of the following: 1. If there are no disk drives available in ready state, insert additional disk drives and make sure the drives are in ready state. 2. If no virtual disks are present, click <create virtualdisk link> and create at least one virtual disk. 3. If PCIe SSD drives are inserted into the enclosure or attached to the backplane.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0678

Message
Unable to perform Prepare to Remove or Secure Erase operations on PCIe SSD disk drives.
Detailed Description
Unable to perform Prepare to Remove or Secure Erase operations on the PCIe SSD disk drives.
Recommended Response Action
Make sure PCIe SSD disk drives are inserted into the enclosure or attached to the backplane and retry the operation. If the issue persists, contact your service provider.
Category
Storage (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0679

Message
A job operation is already running. Retry the operation after the existing job is completed.
Detailed Description
Unable to process the request because a job operation is already running.
Recommended Response Action
Wait until the running job is completed or delete the scheduled job and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC068

Message
SHA256Password and Plain Password cannot be imported together.
Detailed Description
Both SHA256Password and Plain Password cannot be attempted to set together on Configuration import per user.
Recommended Response Action
One of either SHA256Password or Plain password can be attempted to be imported for an user.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0680

Message
Server iDRAC user credentials and/or BIOS passwords are not currently set to default credentials. The USB Configuration XML feature is not available unless default credentials are set.
Detailed Description
The USB Configuration XML feature is not available if the iDRAC user credentials and BIOS passwords are not set to default values.
Recommended Response Action
Reset the iDRAC user credentials and BIOS passwords to default and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0681

Message
Shared component updates through the Server OS or Lifecycle controller cannot be applied because the CMC setting for Chassis Management at Server Mode is not set to Manage and Monitor.
Detailed Description
Shared component updates through the Server OS or Lifecycle controller cannot be applied because the CMC setting for Chassis Management at Server Mode is not set to Manage and Monitor.
Recommended Response Action
To enable this feature do the following: 1) Launch CMC Web UI. 2) Navigate to Chassis Overview -> Setup -> General, and select Manage and Monitor option for the Chassis Management at Server Mode. 3) Click Apply to save changes in CMC. 4) Retry the operation in iDRAC. For more information, refer to the CMC User Guide.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0682

Message
Enabling iDRAC Direct USB Configuration XML allows any USB key containing a correctly formatted configuration XML file to reconfigure the server when plugged into the USB management port identified by the wrench icon. This may include operations on RAID configurations, user accounts, and alert settings.
Detailed Description
Enabling iDRAC Direct USB Configuration XML allows any USB key containing a correctly formatted configuration XML file to reconfigure the server when plugged into the USB management port identified by the wrench icon. This may include operations on RAID configurations, user accounts, and alert settings.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0683

Message
Unable to perform split mode configuration on enclosure(s).
Detailed Description
Unable to perform split mode configuration on enclosure(s).
Recommended Response Action
Check the following: 1) The controller must have Real Time Configuration Capability and the associated enclosure(s) must have Split Mode Capability in order to perform the operation. 2)The controller(s) associated with the enclosure(s) support real time configuration. To verify the controller real time configuration support, go to the Controller Properties page, select the required controller and verify the Real Time Configuration Capability value.3)The enclosure(s) supports split mode configuration. To verify the enclosure, go to the Enclosure Properties page, select the required enclosure, and verify the Enclosure Split Mode Capability property value.<br />"
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0684

Message
Unable to perform split mode configuration on the selected enclosures, because Lifecycle Controller is not enabled.
Detailed Description
Unable to perform split mode configuration on the selected enclosures, because Lifecycle Controller is not enabled.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0685

Message
A pending operation has been created for this arg1 operation.
Arguments
arg1 = task name
Detailed Description
A pending operation has been created for this operation identified in the message.
Recommended Response Action
To view the pending operations click the Pending Operations button.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0686

Message
Some of the applied pending operations were not created.
Detailed Description
Some of the applied pending operations were not created.
Recommended Response Action
View successful pending operations by clicking the Pending Operations button.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0687

Message
Some of the applied pending operations were not created.
Detailed Description
Some of the applied pending operations were not created.
Recommended Response Action
Choose to create a job for the successful operations. View successful pending operations using the Pending Operations button or click Cancel to quit job creation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0688

Message
Applying this configuration operation will also apply all existing pending operations on the arg1 . #{View Pending Operations link}
Arguments
arg1 = controller_name
Detailed Description
Applying this configuration operation will also apply all existing pending operations on the controller identified in the message.
Recommended Response Action
Click Create Job button to create the configuration job. Click Cancel to quit job creation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0689

Message
Unable to create a virtual disk on the selected disk drives, because Lifecycle Controller is not enabled.
Detailed Description
Unable to create a virtual disk on the selected disk drives, because Lifecycle Controller is not enabled.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC069

Message
Unable to complete the operation because the string length is less than the minimum supported length.
Detailed Description
Unable to complete the operation because the string length is less than the minimum supported length.
Recommended Response Action
Enter a string value that is greater than the minumum supported length and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0690

Message
The iDRAC Service Module is not installed on the operating system of the server.
Detailed Description
The iDRAC Service Module is not installed on the operating system of the server.
Recommended Response Action
Install the iDRAC Service Module and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0692

Message
Unable to assign and un-assign physical disk drives as global hotspare(s), because Lifecycle Controller is not enabled.
Detailed Description
Unable to assign and un-assign physical disk drives as global hotspare(s), because Lifecycle Controller is not enabled.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0693

Message
Pending operations are created for the selected operations on the selected physical disk drives.
Detailed Description
Pending operations are created for the selected operations on the selected physical disk drives.
Recommended Response Action
To view the pending operations, click the Pending Operations button.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0694

Message
Unable to configure the attributes of the selected controller, because Lifecycle Controller is not enabled.
Detailed Description
Unable to configure the attributes of the selected controller, because Lifecycle Controller is not enabled.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0695

Message
Unable to perform security key operations on the selected controller, because Lifecycle Controller is not enabled.
Detailed Description
Unable to perform security key operations on the selected controller, because Lifecycle Controller is not enabled.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0696

Message
Unable to retrieve the hardware overview information because the server is turned off.
Detailed Description
The iDRAC is unable to retrieve hardware overview related information while the server is turned off.
Recommended Response Action
Turn the server on to view the hardware overview information.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0697

Message
Choose to create a job from the existing successfull pending operations.
Detailed Description
Choose to create a job from the existing successfull pending operations.
Recommended Response Action
Do one of the following: 1) Click Pending Operations button to view pending operations. 2) Click Create Job button to create a configuration job. 3) Click Cancel button to quit job creation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0698

Message
Unable to modify USB management settings because the USB device is currently in use.
Detailed Description
Unable to modify USB management settings because the USB device is currently in use.
Recommended Response Action
Wait for the current USB operations to complete and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

RAC0699

Message
Invalid value for Minimum Fan Speed.
Detailed Description
The value for Minimum Fan Speed must be within the range identified in the Recommended Response Action.
Recommended Response Action
Enter a value between <min>-<max>.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC070

Message
The SSL Web-Server certificate was successfully restored to factory defaults.
Detailed Description
The SSL Web-Server certificate was successfully restored to factory defaults.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0700

Message
Email page successful to arg1 .
Arguments
arg1 = email address
Detailed Description
An email page was successfully sent.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0701

Message
Requested system powerup.
Detailed Description
Requested system powerup.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0702

Message
Requested system powercycle.
Detailed Description
Requested system powercycle.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0703

Message
Requested system hardreset.
Detailed Description
Requested system hardreset.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0704

Message
Requested system powerdown.
Detailed Description
Requested system powerdown.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0705

Message
Requested system graceful shutdown.
Detailed Description
Requested system graceful shutdown.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0706

Message
Requested system NMI.
Detailed Description
Requested system NMI.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0707

Message
Primary Firmware image is invalid. Currently booted from backup image. To restore primary image, update the firmware.
Detailed Description
Primary Firmware image is invalid. Currently booted from backup image. To restore primary image, update the firmware.
Recommended Response Action
Acquire an iDRAC firmware image of the version desired. Using the latest version available is recommended. Update the iDRAC firmware.
Category
Updates (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0708

Message
Previous reboot was due to a firmware watchdog timeout.
Detailed Description
Previous reboot was due to a firmware watchdog timeout.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0709

Message
Unknown server inserted into chassis.
Detailed Description
Unknown server inserted into chassis.
Recommended Response Action
Acquire the latest Chassis Management Controller (CMC) firmware that supports the server indicated and update the CMC to at least that version.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC071

Message
Unable to perform the iDRAC reset operation because the firmware upgrade operation is in progress.
Detailed Description
The iDRAC reset operation cannot be completed because a firmware upgrade operation is in progress.
Recommended Response Action
Wait for the current update process to complete and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0710

Message
Server link tuning error.
Detailed Description
Server link tuning error.
Recommended Response Action
Ensure that the IO Module (IOM) and Mezzanine (Mezz) cards are appropriately matched. Check the M1000e Hardware Manual for correct component compatibility.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0711

Message
Unknown power on response from the CMC.
Detailed Description
Unknown power on response from the CMC.
Recommended Response Action
Try reseting the CMC. Also try reseating the server.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0712

Message
Server failed to power up due to zero power allocated.
Detailed Description
Server failed to power up due to zero power allocated.
Recommended Response Action
Utilize the Chassis Management Controller web interface to check available power and server power requirements. If sufficient power is available, allocate power necessary and retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0713

Message
Server failed to power up due to fabric mismatch.
Detailed Description
Server failed to power up due to fabric mismatched.
Recommended Response Action
Ensure that the hardware comtibility between the IO Module (IOM) and the Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct component compatibility.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0714

Message
Server failed to power up due to noncontinuous power action.
Detailed Description
Server failed to power up due to noncontinuous power action.
Recommended Response Action
Utilize the Chassis Management Controller web interface to check available power and server power requirements. If sufficient power is available, allocate power necessary and retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0715

Message
Image file does not exist in the given remote share path.
Detailed Description
Image file does not exist in the given remote share path.
Recommended Response Action
Ensure that the image file is available on the share path provided. Retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0716

Message
Unable to unmount remote share.
Detailed Description
Unable to unmount remote share.
Recommended Response Action
Retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0717

Message
Remote share unmounted successfully.
Detailed Description
Remote share unmounted successfully.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0718

Message
Remote File Share service is busy with the previous connection.
Detailed Description
Remote File Share service is busy with the previous connection.
Recommended Response Action
Stop the Remote File Share session and retyr the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0719

Message
Not able to connect to remote file share. Virtual media devices are already in use.
Detailed Description
Not able to connect to remote file share. Virtual media devices are already in use.
Recommended Response Action
Stop existing Virtual Media sessions and retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC072

Message
Unable to perform the iDRAC reset to factory defaults operation because the firmware upgrade is in progress.
Detailed Description
The iDRAC reset to factory defaults operation cannot be completed because a firmware upgrade operation is in progress.
Recommended Response Action
Wait for the current update process to complete and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0720

Message
Unable to mount remote share arg1 .
Arguments
arg1 = sharename
Detailed Description
Unable to mount remote share.
Recommended Response Action
Retry the operation.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0721

Message
Remote share mounted successfully arg1 .
Arguments
arg1 = sharename
Detailed Description
Remote share mounted successfully.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0722

Message
Failed to program the Chassis assigned MAC address for the NIC.Integrated. arg1 .
Arguments
arg1 = NDC slot number
Detailed Description
Failed to program the Chassis assigned MAC address for the NIC.Integrated in the specified slot number.
Recommended Response Action
Reseat the server and retry.
Category
Audit (RAC = RAC Event)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0723

Message
The firmware version arg1 of the Chassis Management Controller is earlier than the required version arg2 .
Arguments
arg1 = version number, arg2 = version number
Detailed Description
The Chassis Management Controller firmware version identified in the message is earlier than the version required to support the server.
Recommended Response Action
Update the Chassis Management Controller firmware to the required version identified in the message.
Category
Audit (RAC = RAC Event)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*   ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC              

RAC0724

Message
Quick Sync Firmware is successfully updated.
Detailed Description
Quick Sync Firmware is successfully updated.
Recommended Response Action
No response action is required.
Category
Updates (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0725

Message
Unable to update the Quick Sync Firmware.
Detailed Description
Unable to update the Quick Sync Firmware.
Recommended Response Action
No response action is required.
Category
Updates (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0726

Message
Auto-throttling is disabled for the server.
Detailed Description
Auto-throttling is disabled for the server based on a request from the Chassis Management Controller (CMC) because the CMC is restarting..
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0727

Message
Auto-throttling is enabled for the server.
Detailed Description
Auto-throttling is enabled for the server based on a request from the Chassis Management Controller (CMC) because the CMC has restarted.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC0728

Message
The Quick Sync communication is no longer functioning.
Detailed Description
The Quick Sync communication or the connection to the iDRAC is no longer functioning.
Recommended Response Action
Do the following: 1) Remove and reseat the bezel. 2) Turn the bezel on by pressing the activation button. 3) Try the Quick Sync feature again. If the issue persists, contact your technical support provider.
Category
System Health (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC073

Message
Unable to perform the iDRAC reset operation because a vFlash partition creation operation is in progress.
Detailed Description
The iDRAC reset operation cannot be completed because a vFlash partition creation operation is in progress.
Recommended Response Action
Wait for the vFlash partition creation process to complete and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC074

Message
Unable to perform the iDRAC reset to factory defaults operation because a vFlash partition creation operation is in progress.
Detailed Description
The iDRAC reset to factory defaults operation cannot be completed because a vflash partition creation operation is in progress.
Recommended Response Action
Wait for the vFlash partition creation process to complete and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0740

Message
The Prepare to Remove operation will stop any activity on the PCIe SSD device so that it can be removed safely. The device is safe to remove when the disk shows the safe to remove LED pattern.
Detailed Description
The Prepare to Remove operation will stop any activity on the PCIe SSD device so that it can be removed safely. The device is safe to remove when the disk shows the safe to remove LED pattern.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0741

Message
Unable to perform Prepare to Remove or Secure Erase operations on the selected PCIe SSD disk drive(s), because Lifecycle Controller is not enabled.
Detailed Description
Unable to perform Prepare to Remove or Secure Erase operations on the selected PCIe SSD disk drive(s), because Lifecycle Controller is not enabled.Retry the operation after the server has restarted.
Recommended Response Action
To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes. Retry the operation after the server has restarted.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0742

Message
The Secure Erase command will be executed on the selected PCIe SSD disk drives(s) only after the reboot of the system or loss of power to the disk drives(s).
Detailed Description
A Secure Erase operation on a PCIe SSD overwrites all blocks in an encrypted way and all the data on the PCIe SSD device will be permanently lost. The changes will happen after reboot of the system or loss of power to the drive.
Recommended Response Action
Press OK to continue.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0743

Message
Unable to perform storage configuration operations because no storage controllers are detected on the server.
Detailed Description
Unable to perform storage configuration operations because no storage controllers are detected on the server
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0744

Message
Unable to perform storage configuration operations because neither Storage controllers nor PCIe Extenders detected on the system.
Detailed Description
Unable to perform storage configuration operations because neither Storage controllers nor PCIe Extenders detected on the system.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0745

Message
There are no pending operations present on the selected component group.
Detailed Description
There are no pending operations on the selected component group.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0746

Message
Unable to perform virtual disk (VD) operations, because Lifecycle Controller is not enabled.
Detailed Description
Unable to perform virtual disk(VD) operations, because Lifecycle Controller is not enabled.
Recommended Response Action
Enable the Lifecycle Controller and retry the operation. To enable Lifecycle Controller, restart the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0747

Message
Unable to perform reset configuration on the selected controller, because Lifecycle Controller is not enabled.
Detailed Description
Unable to perform reset configuration on the selected controller, because Lifecycle Controller is not enabled.
Recommended Response Action
Enable the Lifecycle Controller and retry the operation. To enable Lifecycle Controller, reboot the server. During server startup, press F2 to enter System Setup. Go to iDRAC Settings -> Lifecycle Controller, select Enable, and save the changes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0748

Message
The BIOS watchdog timer must be disabled if the Automatic System Recovery option is enabled.
Detailed Description
The BIOS watchdog must be disabled if Automatic System Recovery option is enabled.
Recommended Response Action
Make sure the BIOS watchdog timer is disabled before enabling the Automatic System Recovery option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0749

Message
SNMPv3 User cannot be set to None.
Detailed Description
SNMPv3 User cannot be set to None.
Recommended Response Action
Set the SNMPv3 User to a value other than None and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0750

Message
Unable to access the USB NIC IP address by using PING process.
Detailed Description
The USB NIC IP address cannot be accessed by using the PING process.
Recommended Response Action
Enter another appropriate IP address, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0751

Message
The threshold value entered is less than the lower warning or critical threshold.
Detailed Description
The value for information or warning threshold should not be less than lower critical threshhold value.
Recommended Response Action
Enter a threshold value that is greater than the lower warning or critical threshold values and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0752

Message
The threshold value entered is greater than the upper warning or critical threshold.
Detailed Description
The value for information or warning threshold should not be greater than upper critical threshold value.
Recommended Response Action
Enter a threshold value that is lower than the upper warning or critical threshold values and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0753

Message
Reset iDRAC to apply the pending new certificate. Until iDRAC is reset the old certificate will be active.
Detailed Description
Reset iDRAC to apply the pending new certificate. Until iDRAC is reset old certificate will be active. A manual reset of iDRAC is needed for the new certificate to take into effect.
Recommended Response Action
Click the Reset iDRAC link to reset iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0754

Message
Reset iDRAC to complete the deletion action of the certificate.
Detailed Description
Reset iDRAC to complete custom SSL certificate deletion action. A manual reset of iDRAC is needed for the action to take effect.
Recommended Response Action
Click the Reset iDRAC link to reset iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0755

Message
The selected value is not supported on this server.
Detailed Description
The selected value is not supported on this server.
Recommended Response Action
Retry the operation with another value.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0756

Message
Unable to retrieve the fan information.
Detailed Description
Fan information cannot be displayed. This situation may occur if the server is powered off.
Recommended Response Action
Power on the server. If the server is already powered on, wait for a few minutes and refresh the page. If the problem persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0757

Message
USB Management Port is currently disabled in BIOS configuration.
Detailed Description
The requested operation using the USB Management Port cannot be completed because the port is disabled in BIOS configuraton.
Recommended Response Action
Enable the USB Management Port in BIOS configuration to use this feature
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0758

Message
Tech Support Report (TSR) data is being collected. This operation will take less than arg1 minutes.
Arguments
arg1 = collection time
Detailed Description
The Tech Support Report generation will take the time identified in the message to complete.
Recommended Response Action
To cancel the reports collection click Cancel.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0759

Message
A running Tech Support Report job has been cancelled.
Detailed Description
A running Tech Support Report job has been cancelled.
Recommended Response Action
Click Job Queue button to view the status of the cancelled job.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0760

Message
Unable to perform physical disk(s) storage configuration operations for the selected controller.
Detailed Description
Unable to perform storage configuration operations on physical disk drive(s) as there are no disk drive(s) available with Ready/RAID/NON-RAID state or the selected controller is in HBA mode.
Recommended Response Action
Check the following: 1) If there are no physical disk drive(s) in either Ready state or in RAID/NON-RAID state, insert additional disk drive(s). 2) If the Controller(s) are in HBA mode, switch the controller(s) to RAID mode. To switch controller(s) to RAID mode using the F2 System Setup utility, go to Device Settings > RAID Controller > Controller Management > Advanced Controller Management > Switch to RAID mode.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0761

Message
Unable to retrieve system inventory.
Detailed Description
The system inventory cannot be retrieved because another system inventory operation may already be in progress or due to an internal issue whether or not Collect System Inventory On Restart (CSIOR) is enabled or disabled.
Recommended Response Action
A system inventory operation may be in progress. Wait for the operation to complete and retry the operation. If no other system inventory operation is in progress, enable the Collect System Inventory On Restart (CSIOR) feature, reboot the system, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0762

Message
Unable to perform a firmware update because a valid catalog file is not available on the network share.
Detailed Description
Unable to perform a firmware update because a valid catalog file is not available on the network share.
Recommended Response Action
Make sure that a valid catalog file is available on the network share and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0763

Message
Unable to configure the port number that is entered because the port number is already in use.
Detailed Description
Unable to configure the port number that is entered because the port number is already in use.
Recommended Response Action
Enter a port number that is not already in use and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0764

Message
Selecting a higher SSL encryption enhances the security. However, the cryptography settings for your virtual machine environment (JVM, IcedTea) may require installing the Unlimited Strength Java Cryptography Extension Policy Files to permit usage of iDRAC plugins such as vConsole with this higher level of encryption. NOTE: Using this level of encryption may have import or export implications. For more guidance, contact your legal department.
Detailed Description
Selecting a higher SSL encryption enhances the security. However, the cryptography settings for your virtual machine environment (JVM, IcedTea) may require installing the Unlimited Strength Java Cryptography Extension Policy Files to permit usage of iDRAC plugins such as vConsole with this higher level of encryption. NOTE: Using this level of encryption may have import or export implications. For more guidance, contact your legal department.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC0765

Message
Unable to access the operating system (OS) IP address by using the Ping process because an incorrect IP address is entered.
Detailed Description
The OS IP address cannot be accessed by using the Ping process because an incorrect IP address is entered.
Recommended Response Action
Enter a correct IP address, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0766

Message
Unable to assign USB NIC IP address arg1 to the OSBMC device because only Link Local IP address can be allowed.
Arguments
arg1 = IP address
Detailed Description
The USB NIC IP address identified in the message cannot be assigned to the OSBMC device because only Link Local IP address can be allowed.
Recommended Response Action
Enter appropriate Link Local IP address, and then retry the operation. For information about supported IP addresses, refer to the iDRAC Users Guide available at the support site.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0767

Message
Unable to assign USB NIC IP address arg1 to the OSBMC device because IP address setting conflicts with existing network interface IP.
Arguments
arg1 = IP address
Detailed Description
The USB NIC IP address identified in the message cannot be assigned to the OSBMC device because IP address setting conflicts with existing network interface IP.
Recommended Response Action
Enter an unique IP address for OSBMC USB NIC that is not the same as another NICs IP address, and then retry the operation. For information about supported IP addresses, refer to the iDRAC Users Guide available at the support site.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0801

Message
iDRAC has reset to default settings.
Detailed Description
iDRAC closes all the existing sessions and all configuration settings are set to default values. The iDRAC IP address is set to the default static IP address.
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC0901

Message
Invalid syntax. The -t option value must set to 1.
Detailed Description
The syntax of the specified command is invalid. In this case, the usage of the -t option is invalid.
Recommended Response Action
See the help text/documentation for the valid syntax of the subcommand.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0902

Message
The -f option requires -d to also be specifed.
Detailed Description
The syntax of the specified command is invalid. In this case, the usage of the -f option is invalid.
Recommended Response Action
See the help text/documentation for the valid syntax of the subcommand.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0903

Message
The -d option cannot be used with any other options.
Detailed Description
The syntax of the specified command is invalid. In this case, the usage of the -d option is invalid.
Recommended Response Action
See the help text/documentation for valid syntax of the subcommand.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0904

Message
The remote file location is not accessible or reachable.
Detailed Description
The iDRAC cannot access the remote file location. The credentials or path to the remote file location is incorrect or iDRAC cannot connect to the network address.
Recommended Response Action
Confirm that the path and credentials to remote file are correct, and check that the iDRAC can connect to the network address.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0905

Message
Failed to get the USC version details.
Detailed Description
Unable to obtain the USC version details.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0906

Message
Operation failed.
Detailed Description
Unable to perform the requested operation.
Recommended Response Action
Try again later. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0907

Message
System ID LED blink on.
Detailed Description
The System ID LED was successfully set to on.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC0908

Message
System ID LED blink off.
Detailed Description
The System ID LED was successfully set to off.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0909

Message
Invalid subcommand syntax: Specify the object name.
Detailed Description
The specified command is missing object name syntax.
Recommended Response Action
Specify the correct subcommand object name syntax. See the help text or documentation for valid syntax.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0910

Message
Invalid subcommand syntax: Specify group and object name.
Detailed Description
The specified command is missing group and object name syntax.
Recommended Response Action
Specify the correct subcommand group and object name syntax. See the help text or documentation for the valid syntax.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0911

Message
Data about version details is unavailable.
Detailed Description
Unable to retrieve version details.
Recommended Response Action
Try again later. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC0912

Message
Unable to connect to RAC at specified IP address.
Detailed Description
The management system could not connect to the iDRAC.
Recommended Response Action
Verfiy whether the IP address of the remote iDRAC is correct. Verify whether connectivity exists between the management system and the iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC1000

Message
Unable to set the object value for iDRAC IPv6 address or gateway.
Detailed Description
Unable to set the object value for iDRAC IPv6 Address1 and IPv6 Gateway, because the object IPv6 Autoconfig is enabled.
Recommended Response Action
Disable the object IPv6 AutoConfig using "racadm set iDRAC.IPv6.AutoConfig <0 | Disabled >", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1001

Message
Unable to set the object value for iDRAC IPv6 DNS1 or DNS2.
Detailed Description
Unable to set the object value for iDRAC IPv6 DNS1 or DNS2, because the object DNSFromDHCP6 is enabled.
Recommended Response Action
Disable the object DNSFromDHCP6 using "racadm set iDRAC.IPv6.DNSFromDHCP6 <0 | Disabled>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1002

Message
Active Directory Single Sign On (SSO) cannot be enabled.
Detailed Description
The Active Directory SSO cannot be enabled, because the object SmartCardLogonEnable is enabled.
Recommended Response Action
Disable the object SmartCardLogonEnable using "racadm set iDRAC.SmartCard.LogonEnable <0 | Disabled>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1003

Message
The smart card certificate revocation list (CRL) cannot be enabled.
Detailed Description
The smart card certificate revocation list (CRL) cannot be enabled, because the object SmartCardLogonEnable is disabled.
Recommended Response Action
Enable the object SmartCardLogonEnable using "racadm set iDRAC.SmartCard.SmartCardLogonEnable <1 | Enabled>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1004

Message
The smart card login cannot be enabled.
Detailed Description
The smart card login cannot be enabled, because the Active Directory Single Sign On is enabled.
Recommended Response Action
Disable Active Directory Single Sign On (SSO) using "racadm set iDRAC.ActiveDirectory.SSOEnable <0 | Disabled>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1005

Message
Successfully exported hardware inventory.
Detailed Description
The hardware inventory was successfully exported.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1006

Message
Unable to process the arg1 , and the update was not applied.
Arguments
arg1 = file name
Detailed Description
The update was not applied because of one of the following reasons: 1) The Update Package is invalid. 2) Lifecycle Controller is corrupted. 3) Another update is in progress.
Recommended Response Action
Do one of the following and retry the operation: 1) Dowload the correct Update Package from your service provider. 2) Use the Lifecycle Controller repair package to repair Lifecycle Controller. For more information, see Lifecycle Controller Users Guide. 3) Wait until the current update operation is complete.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1007

Message
The job arg1 cannot be deleted.
Arguments
arg1 = job ID
Detailed Description
The job specified in the meesage cannot be deleted when it is Running, Scheduled, or tranitioniong from Downloading to Scheduled.
Recommended Response Action
Wait until the specified job is completed, or reboot the system to move the job to Completed state. To view the job status, use "racadm jobqueue view -i <Job_ID>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1008

Message
The Active Directory object DCLookupByUserDomain cannot be disabled.
Detailed Description
The Active Directory object DCLookupByUserDomain cannot be disabled, because the Active Directory object DCLookupDomainName is not configured.
Recommended Response Action
Configure the Active Directory object DCLookupDomainName using "racadm set iDRAC.ActiveDirectory.DCLookupDomainName <Name>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1009

Message
The Active Directory objects DCLookupEnable or GCLookupEnable cannot be enabled.
Detailed Description
The Active Directory objects DCLookupEnable or GCLookupEnable cannot be enabled, because IPv4.DNS1, IPv4.DNS2, IPv6.DNS1, or IPv6.DNS2 is not configured.
Recommended Response Action
Configure IPv4.DNS1, IPv4.DNS2, IPv6.DNS1, or IPv6.DNS2 using racadm set command, and retry the operation. For example, "racadm set iDRAC.IPv4.DNS1 <address>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1010

Message
Unable to set the power cap value.
Detailed Description
The power cap cannot be set if the object Power.Cap is disabled.
Recommended Response Action
Enable Power Cap setting using "racadm set System.Power.Cap.Enable < 1 | Enabled >", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1011

Message
The OS to iDRAC pass-through cannot be enabled.
Detailed Description
The OS to iDRAC pass-through cannot be enabled, because the NIC is in Dedicated mode.
Recommended Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>", and retry the opeation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1012

Message
Unable to change the auto-negotiation state for the current NIC selection mode.
Detailed Description
Unable to change the auto-negotiation state for the current NIC selection mode, because the iDRAC NIC is in dedicated mode.
Recommended Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1013

Message
The SNMPv3 authentication protocol state cannot be set to None if the SNMPv3 privacy protocol state is set to None.
Detailed Description
For any iDRAC user, SNMPv3 authentication protocol can be changed to "None" only if the SNMPv3 privacy protocol state is set to "None".
Recommended Response Action
Change the SNMPv3 privacy protocol state to None using "racadm set iDRAC.Users.<index>.SNMPv3PrivacyType none", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1014

Message
The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3 authentication protocol state is set to "None".
Detailed Description
The SNMPv3 privacy protocol cannot be configured to AES or DES mode if SNMPv3 authentication protocol state is set to "None".
Recommended Response Action
To configure the SNMPv3 Privacy Protocol for a specified iDRAC user, change the SNMPv3 Authentication Protocol to either MD5 or SHA state using "racadm set idrac.users.<index>.SNMPv3AuthenticationType <value>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1016

Message
The specified user already exists. Duplicate user names are not allowed.
Detailed Description
iDRAC does not allow duplicate user names for each of the 16 users.
Recommended Response Action
Make sure that each of the 16 user names are unique.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1017

Message
Successfully modified the object value and the change is in pending state.
Detailed Description
Any staged operation requires a job and system reboot to apply the object values.
Recommended Response Action
To apply modified value, create a configuration job and reboot the system. To create the commit and reboot jobs, use "jobqueue" command. For more information about the "jobqueue" command, see RACADM help.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1018

Message
The specified object or syntax is invalid.
Detailed Description
This occurs when an incorrect syntax is used or an incorrect object is specified during the command invocation.
Recommended Response Action
Make sure to use the correct syntax and correct object names, and retry the operation. For information related to the corresponding group, see RACADM help or the RACADM Users Guide.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1019

Message
The specified object is not supported for the current system configuration.
Detailed Description
Some objects have dependencies on other objects that are required to perform a task. The specified object is not available because of such dependencies.
Recommended Response Action
Verify the object dependency using "racadm help <device class>.<groupname>.<objectname>", and retry the operation. For example, racadm help NIC.VndrConfigGroup.1.VirtWWPN.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1020

Message
No objects are available under the specified group for the current system configuration.
Detailed Description
Some objects have dependencies on other objects that are required to perform a task. The specified group does not contain any objects, because the dependent objects are not part of the current system configuration.
Recommended Response Action
Verify the dependencies of the objects under the specified group using "racadm help <device class>.<groupname>", and retry the operation. For example, "racadm help NIC.IscsiSecondTgtParams".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1021

Message
NIC objects are not available in the current system configuration.
Detailed Description
NIC objects are not available if NIC devices are not installed in the system, or if some iDRAC services are busy.
Recommended Response Action
Make sure the NIC devices are correctly installed in the system and retry the operation after the Collect System Inventory On Restart (CSIOR) feature has updated the system inventory. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1023

Message
Unable to create the configuration job.
Detailed Description
Configuration jobs are created only if at least one object on the device or component (for example, NIC.Slot.1 or BIOS) has a pending value to be applied.
Recommended Response Action
Make sure that there is at least one object on the specified device or component that has a pending vlaue, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1024

Message
Successfully scheduled a job.
Detailed Description
The pending value is applied during the next reboot of system.
Recommended Response Action
Verify the job status using "racadm jobqueue view -i JID_xxxxx" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1025

Message
The specified object is read-only and cannot be modified due to an object dependency.
Detailed Description
Some objects have dependencies on other objects that are required to perform a task. However, some of the objects are read-only because of the current system configuration and the values of the dependent objects.
Recommended Response Action
Verify the object dependency using "racadm help <device class>.<groupname>.<objectname>", and retry the opearation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1026

Message
A custom signing certificate does not exist.
Detailed Description
A custom signing certificate must be present in the system to delete or downlod the certificate.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1027

Message
Successfully sent the alert for the specified event to the configured destination.
Detailed Description
A test event was generated and the alert was successfully sent to the destination.
Recommended Response Action
Verify if the alerts were received by the configured tdestination. Otherwise, reconfigure the destination and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1028

Message
Unable to download the specified certificate type.
Detailed Description
The certificate cannot be downloaded if the certificate type specified is other than "1", "2", or "3".
Recommended Response Action
Make sure to specify either "1", "2", or "3" for the certificate type (-t) option, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1029

Message
Unable to delete the specified certificate type.
Detailed Description
The certificate cannot be deleted if the certificate type specified is not "3".
Recommended Response Action
Make sure to specify "3" for the certificate type (-t) option, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1030

Message
The custom signing certificate was deleted.
Detailed Description
The custom signing certificate present on iDRAC was deleted.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1031

Message
Unable to delete the custom signing certificate.
Detailed Description
The custom signing certificate on iDRAC cannot be deleted because of an internal error.
Recommended Response Action
Verify if iDRAC has a custom signing certificate. If it has the certificate, retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1032

Message
arg1 jobs was cancelled by the user.
Arguments
arg1 = Job ID or ALL
Detailed Description
The job specified in the message were cancelled.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1033

Message
Unable to retrieve the server component software inventory.
Detailed Description
The server component software inventory cannot be retrieved because of an internal error.
Recommended Response Action
Make sure to enable Collect System Inventory On Restart (CSIOR) feature, reboot the server, and retry the operation. If CSIOR is already enabled, restart iDRAC using "racadm racreset" command, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1034

Message
This action will ungracefully turn off the server.
Detailed Description
This operation will cause the server to shutdown immediately. This may result in the applications losing data.
Recommended Response Action
Before continuing, exit all the programs running on this server, and make sure that there is no inbound and outbound traffic associated with this server. Inability to do so may prevent all the servers in the chassis from accessing the shared-storage devices for up to two minutes. To continue the operation, enter a -f at the end of command "racadm serveraction powerdown -f", and then retry.
Category
System Health (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1035

Message
There are no pending values to be cleared.
Detailed Description
The command is unable to clear the pending state for attributes of the specified component because there are no pending values.
Recommended Response Action
Make sure that there is at least one attribute on the specified device has a pending value, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC1036

Message
Successfully cleared pending attribute(s) for the group specified.
Detailed Description
Successfully cleared pending values for attributes in the group specified.
Recommended Response Action
To verify, run the RACADM command "racadm get group".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC1037

Message
Unable to clear pending attribute(s).
Detailed Description
Unable to clear pending attribute(s). This may be because the FQDD entered is incorrect.
Recommended Response Action
Check that the FQDD entered is correct. View the Help information by running the RACADM command "racadm help clearpending".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1038

Message
Unable to clear pending values for the specified component.
Detailed Description
Unable to clear pending values for the specified component. This may be because there is an existing configuration job for the component.
Recommended Response Action
Make sure that a config job is not scheduled for this component. For more information, view the help command by running the RACADM command "racadm jobqueue help delete".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1039

Message
The subcommand entered is not supported on the specified server.
Detailed Description
The subcommand entered is not supported on the specified server.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1040

Message
Successfully accepted the RAID storage configuration operation. The change is in pending state.
Detailed Description
The requested RAID storage operation was successfully accepted and now must be applied by creating a RAID storage configuration job.
Recommended Response Action
To apply the configuration operation, create a configuration job, and then restart the server. To create the required commit and reboot jobs, run the jobqueue command. For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC1041

Message
Successfully configured the Automatic Update (autoupdate) feature settings.
Detailed Description
Successfully configured the Automatic Update (autoupdate) feature settings.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1042

Message
Unable to configure the Automatic Update (autoupdate) feature settings. The required options are either invalid or not provided.
Detailed Description
One or more required options to configure the Automatic Update (autoupdate) feature are missing.
Recommended Response Action
For more information, view the help details by running the RACADM command "racadm help autoupdatescheduler".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1043

Message
Unable to configure the Automatic Update (autoupdate) feature settings. The option arg1 is either invalid or not provided.
Arguments
arg1 = option name
Detailed Description
The operation did not complete successfully because of an invalid value for the option identified in the message.
Recommended Response Action
Retry with a correct value for the option identified in the message. For more information, view the help details by running the RACADM command "racadm help autoupdatescheduler".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1044

Message
The Automatic Update (autoupdate) feature is not enabled.
Detailed Description
The Automatic Update (autoupdate) feature is not enabled
Recommended Response Action
To enable, run the RACADM command "racadm set lifecyclecontroller.lcattributes.autoupdate 1".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1045

Message
Specifying ftp.dell.com as the catalog source for the Automatic Update feaure may result in frequent system firmware updates because the catalog on ftp.dell.com changes often.
Detailed Description
Individual component firmware updates may occur frequently and cause changes to the catalog on ftp.dell.com. Specifying ftp.dell.com as the catalog source for the Automatic Update feaure may result in frequent system firmware updates.
Recommended Response Action
Creating a custom repository using the Repository Manager tool allows control of the frequency of component firmware updates.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1046

Message
Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured.
Detailed Description
Unable to view the Automatic Update (autoupdate) feature settings because the feature has not been configured.
Recommended Response Action
Configure the Automatic Update feature by running the RACADM command "racadm autoupdatescheduler create" with the desired option settings.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1047

Message
Successfully cleared the Automatic Update (autoupdate) feature settings.
Detailed Description
Successfully cleared the Automatic Update(autoupdate) feature settings.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1048

Message
Unable to clear the Automatic Update (autoupdate) feature settings because there is currently no configuration.
Detailed Description
The Automatic Update (autoupdate) feature settings must already exist in order to be cleared.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1049

Message
Successfully configured the Automatic Backup (autobackup) feature settings.
Detailed Description
Successfully configured the Automatic Backup (autobackup) feature settings.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1050

Message
Unable to configure the Automatic Backup (autobackup) feature settings. The required options are either invalid or not provided.
Detailed Description
One or more required options to configure the Automatic Backup (autobackup) feature are missing.
Recommended Response Action
For more information, view the help details by running the RACADM command "racadm help systemconfig backup".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1051

Message
Unable to configure the Automatic Backup (autobackup) feature settings. The option arg1 is either invalid or not provided.
Arguments
arg1 = option name
Detailed Description
The operation did not complete successfully because of an invalid value for the option identified in the message.
Recommended Response Action
Retry with a correct value for the option identified in the message. For more information, view the help details by running the RACADM command "racadm help systemconfig backup".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1052

Message
The Automatic Backup (autobackup) feature is not enabled.
Detailed Description
The Automatic Backup (autobackup) feature is not enabled.
Recommended Response Action
To enable, run the RACADM command "racadm set lifecyclecontroller.lcattributes.autobackup 1".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1053

Message
Unable to view the Automatic Backup (autobackup) feature settings because the feature has not been configured.
Detailed Description
Unable to view the Automatic Backup (autobackup) feature settings because the feature has not been configured.
Recommended Response Action
Configure the Automatic Backup feature by running the RACADM command "racadm systemconfig backup" with the desired option settings.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1054

Message
Successfully cleared the Automatic Backup (autobackup) feature settings.
Detailed Description
Successfully cleared the Automatic Backup (autobackup) feature settings.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1055

Message
Unable to clear the Automatic Backup (autobackup) feature settings because there is currently no configuration.
Detailed Description
The Automatic Backup (autobackup) feature settings must already exist in order to be cleared.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1056

Message
Rollback operation initiated successfully.
Detailed Description
The requested firmware Rollback operation was initiated successfully.
Recommended Response Action
No response action is required
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1057

Message
Rollback operation did not complete successfully. The component identifier specified is not valid or does not have a rollback firmware image available.
Detailed Description
Rollback operation did not complete successfully. The component identifier (FQDD) specified in the operation is not valid or does not have a Rollback firmware image available.
Recommended Response Action
Run the RACADM command "racadm swinventory" to see the list of Rollback firmware images available and the corresponding component identifier (FQDD).
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC1058

Message
Rollback operation did not complete successfully because Lifecycle Controller is disabled.
Detailed Description
The requested firmware Rollback operation did not complete successfully because Lifecycle Controller is disabled.
Recommended Response Action
Run the RACADM command "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1059

Message
Rollback operation could not be performed because another firmware update job is running.
Detailed Description
The requested firmware rollback operation could not be performed because another firmware update job is running or being scheduled.
Recommended Response Action
Wait until the existing firmware update jobs are completed or scheduled before retrying the operation. To monitor the status of the existing jobs, run the RACADM command "racadm jobqueue view". If the issue persists, restart the iDRAC and then retry the operation after the iDRAC has finished restarting.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1060

Message
System inventory may not becurrent because the Collect System Inventory On Restart (CSIOR) feature is disabled.
Detailed Description
The system inventory information may not be current because the Collect System Inventory On Restart (CSIOR) feature is disabled.
Recommended Response Action
To enable the CSIOR feature, run the RACADM command "racadm set LifecycleController.LCAttributes.CollectSystemInventoryOnRestart 1". Then restart the server to cause system inventory information to be collected.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1061

Message
SystemErase operation initiated successfully.
Detailed Description
The requested SystemErase operation was initiated successfully.
Recommended Response Action
Check the job status by running the RACADM command: "racadm jobqueue view -i <JobID>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1062

Message
Unable to initiate the SystemErase operation. The component identifier specified is not valid.
Detailed Description
Unable to initiate the requested SystemErase operation. The component identifier specified is not valid.
Recommended Response Action
Run the RACADM command "racadm help systemerase" to see the list of supported components.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1063

Message
Unable to initiate the SystemErase operation because Lifecycle Controller is disabled.
Detailed Description
Unable to initiate the SystemErase operation because Lifecycle Controller is disabled.
Recommended Response Action
Run the RACADM command "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1064

Message
Unable to initiate the SystemErase operation because another instance of SystemErase job is already in progress.
Detailed Description
Unable to initiate the requested SystemErase operation because another SystemErase job is already in progress.
Recommended Response Action
To check the job status, run the RACADM command "racadm jobqueue view" and retry the operation after the current SystemErase operation has completed.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1065

Message
Unable to initiate the SystemErase operation because iDRAC encountered an internal issue.
Detailed Description
Unable to initiate the SystemErase operation because iDRAC encountered an internal issue.
Recommended Response Action
Retry the operation. If the issue persists, restart the iDRAC and then retry the operation after the iDRAC has finished restarting.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1067

Message
Unable to set the minimum non critical threshold value of arg1 , because the value entered is lesser than, or equal to the minimum critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The minimum non critical threshold value identified in the message cannot be set, because the value entered is lesser than, or equal to the minimum critical threshold value.
Recommended Response Action
Check the minimum critical threshold level using an appropriate RACADM command. For example, to view the minimum threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1068

Message
Unable to set minimum non critical threshold value of arg1 , because the value entered is greater than, or equal to the maximum non critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The minimum non critical threshold value identified in the message cannot be set, because the value entered is greater than, or equal to the maximum non critical threshold value.
Recommended Response Action
Check the maximum non critical threshold level using an appropriate RACADM command. For example, to view the maximum non critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1069

Message
Unable to set minimum non critical threshold value of arg1 , because the value entered is greater than, or equal to the maximum critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The minimum non critical threshold value identified in the message cannot be set, because the value entered is greater than, or equal to the maximum critical threshold value.
Recommended Response Action
Check the maximum critical threshold level using an appropriate RACADM command. For example, to view the maximum critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1070

Message
Unable to set the maximum non critical threshold value of arg1 , because the value entered is greater than, or equal to the maximum critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The maximum non critical threshold value identified in the message cannot be set, because the value entered is greater than or equal to the maximum critical threshold value.
Recommended Response Action
Check the maximum critical threshold level using an appropriate RACADM command. For example, to view the maximum critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1071

Message
Unable to set maximum non critical threshold value of arg1 , because the value entered is less than, or equal to the minimum non critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The maximum non critical threshold value identified in the message cannot be set, because the value entered is less than or equal to the minimum non critical threshold value.
Recommended Response Action
Check the minimum non critical threshold level using an appropriate RACADM command. For example, to view the minimum non critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1072

Message
Unable to set maximum non critical threshold value of arg1 , because the value entered is less than, or equal to the minimum critical threshold value.
Arguments
arg1 = System Board Inlet Temp
Detailed Description
The maximum non critical threshold value identified in the message cannot be set, because the value entered is less than or equal to the minimum critical threshold value.
Recommended Response Action
Check the minimum critical threshold level using an appropriate RACADM command. For example, to view the minimum critical threshold value of a sensor, run the racadm getsensorinfo command at the command line interface, and then retry the operation. For more information about other RACADM commands, run the racadm help command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1073

Message
Unable to reset the threshold value of sensor arg1 because the capability to reset this sensor threshold value is not supported.
Arguments
arg1 = sensor name
Detailed Description
The threshold value of the sensor identified in the message cannot be successfully set because the capability reset the sensor threshold value is not supported.
Recommended Response Action
No response action is required. For more information about resetting the threshold level of a sensor, run the "racadm getsensorinfo" command at the command line interface (CLI), and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1109

Message
Unable to run the command, because an incorrect Share type is entered.
Detailed Description
Unable to run the command, because an incorrect Share type was entered.
Recommended Response Action
Enter an appropriate Share location of the following types: FTP, NFS, or CIFS. For more information, run the "racadm help update" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1110

Message
Unable to run the command, because an incorrect Proxy port number was entered.
Detailed Description
Unable to run the command, because an incorrect Proxy port number was entered. The Proxy port value must be a positive integer.
Recommended Response Action
Enter only numbers for a Proxy port value.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1111

Message
Unable to delete the pending values or operations of the specified device.
Detailed Description
Unable to clear pending values or operations from the specified storage device because there are no pending operations for the specified device.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1112

Message
Unable to delete the pending values for the specified device because the iDRAC internal storage is in use by a currently running job.
Detailed Description
Unable to clear the pending state from the attributes for a RAID object. A job is currently running and iDRAC internal storage is in use.
Recommended Response Action
Retry the operation after any currently running jobs have completed. Jobs can be monitored by running the racadm command "racadm jobqueue view".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1113

Message
Unable to perform the preview operation because the options -b, -c, -w, and -s must not be used with the --preview option.
Detailed Description
The configuration XML preview operation cannot be executed because the -b, -s, and -w options must not be used with the --preview option.
Recommended Response Action
Remove the -b, -w, and -s options wihen using the --preview option and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1114

Message
Configuration XML file preview operation job is initiated. Job ID = arg1
Arguments
arg1 = job ID
Detailed Description
The configuration XML preview operation was successfully initiatied and has generated a job with the job ID identified in the message.
Recommended Response Action
Monitor the status of the preview operation job by running the racadm command "racadm jobqueue view -i <job ID>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1115

Message
Unable to run the command, because of insufficient user privileges.
Detailed Description
The command could not be successfully run, because of insufficient privileges for the username supplied.
Recommended Response Action
Make sure that you have appropriate privileges, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1116

Message
Unable to run the command, because the restart flag entered is incorrect.
Detailed Description
The command could not be successfully run, because an incorrect "restart flag" value was entered in the command.
Recommended Response Action
Enter a correct flag value. The recommended values are "true" and "false". Make sure that you have entered the correct value, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1117

Message
Unable to run the command.
Detailed Description
The operation specified in the command could not be successfully completed.
Recommended Response Action
Retry the operation after 2 minutes. If the problem persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1118

Message
Successfully initiated the update operation specified in the command.
Detailed Description
Successfully initiated the update operation specified in the command.
Recommended Response Action
To know about the status of a command that is initiated, run the following command: racadm jobqueue view -I <job ID>.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1119

Message
Unable to generate a comparison report for the specified repository.
Detailed Description
The command could not be successfully run because of one or more of the following reasons: 1. The command does not have "--verifycatalog" in it. 2. The updates available on the repository are not applicable for the operation that is requested.
Recommended Response Action
To generate a comparison report, type "--verifycatalog" in the racadm command, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1120

Message
Unable to run the command, because an incorrect Proxy type is entered.
Detailed Description
The command could not be successfully run, because an incorrect Proxy type value was entered for the -pt option.
Recommended Response Action
Make sure that you entered either "http" or "https" as the proxy type. Enter the correct type, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1121

Message
Unable to run the command, because the data entered for connecting to the Proxy server is insufficient.
Detailed Description
The command could not be successfully run, because one or more values about the proxy server was not entered.
Recommended Response Action
Make sure that you enter the following data, and then retry the operation: - proxy server address - proxy user name - proxy password
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1122

Message
The specified group or object is not supported on the server.
Detailed Description
One or more of the group or component attributes specified in the operation do not exist on the targeted server.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1123

Message
Unable to perform the operation because Fibre Channel (FC) attributes are not available in the current server configuration.
Detailed Description
Fibre Channel (FC) objects are not available if Fibre Channel devices are not installed in the server, or if some iDRAC services are busy.
Recommended Response Action
Do the following: 1) Power off and remove AC or DC power from the server. 2) Make sure the Fibre Channel devices are correctly installed in the server. 3) Restart the server to allow the Collect System Inventory On Restart (CSIOR) feature to update the server inventory. 4) Retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1128

Message
The -l option must be specified if -u and -p options are used.
Detailed Description
Any operation involving remote share (CIFS) cannot continue if the location (-l option) is not specified. The -u and -p options represent the user name and password for the remote share, and -l represents the location of the remote share.
Recommended Response Action
Make sure to specify the location (-l option) of the remote share along with the user name and password, and retry the operation. To view the list of options that can used for the required subcommand, run the RACADM command "racadm help <subcommand>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1129

Message
Unable to modify the BootOnce object.
Detailed Description
The BootOnce object could not be modified, because the FirstBootDevice object is set to either F10, F11, or BIOS.
Recommended Response Action
Configure the FirstBootDevice object to values other than F10, F11, or BIOS and retry the set operation for the BootOnce object. For more information about possible FirstBootDevice values, run the RACADM command "racadm help idrac.serverboot.firstbootdevice".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1130

Message
Unable to complete the operation. This feature is not supported on the currently-used platform.
Detailed Description
The requested operation could not be successfully completed because of an unsupported version of BIOS, USC, and/or iDRAC firmare.
Recommended Response Action
Verify whether or not a correct version of BIOS, Lifecycle Controller, and/or iDRAC firmware is installed. For more information on the appropriate firmware version required, refer to the RACADM Command Line Reference Guide. Also check if there is a limitation in terms of platforms such as monolithic or modular, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1131

Message
iDRAC was successfully reset.
Detailed Description
The iDRAC was reset and is successfully restarted.
Recommended Response Action
None.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1132

Message
Unable to update the firmware. The value entered for an option is invalid.
Detailed Description
The firmware could not be successfully updated, because one or all of the following values are incorrect: a. logon ID b. IP address of TFTP or FTP server c. Full path of the firmware file.
Recommended Response Action
Run the racadm command "racadm help <subcommand>" to get more details about the various options applicable for this command and the values accepted by the command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1133

Message
BIOSRTDRequested value is modified successfully.The BIOS reset to default values operation is pending a server restart.
Detailed Description
The BIOSRTDRequested attribute was modified successfully.The BIOS reset to default values operation is pending a server restart.
Recommended Response Action
To apply the BIOS default values, restart the server. After the server has restarted, the default BIOS values will be accessible from the iDRAC.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1134

Message
Unable to export the Lifecycle log data, because the export file size larger than 25MB and cannot be processed locally.
Detailed Description
Unable to export the Lifecycle log data, because the export file size larger than 25MB and cannot be processed locally.
Recommended Response Action
Export the Lifiecycle Log to a network file share. Using the RACADM command line utility, run the lclog export command with --complete option and related network file share parameters, and then retry the operation. For more information about the --complete option, run the "racadm help lclog export" command at the command line interface.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1135

Message
Unable to run the RACADM command because an internal instrumentation component has stopped functioning.
Detailed Description
The RACADM command could not be run because the internal instrumentation components are either busy or have stopped functioning.
Recommended Response Action
Wait for a minute for the internal instrumentation component to respond, and then retry the operation. If the issue persists, reset the iDRAC by pressing the System ID button for 15 seconds, wait for the iDRAC to finish restarting, and then retry the operation. If the issue continues to persist, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1136

Message
Remote unattended diagnostic execution operation initiated.
Detailed Description
The remote unattended diagnostic execution operation is initiated.
Recommended Response Action
Using the RACADM command line interface, run the "racadm jobqueue view -i <job id>" command to view the status of the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC1137

Message
Remote unattended diagnostic results export operation initiated.
Detailed Description
Remote unattended diagnostic results export operation initiated.
Recommended Response Action
Using the RACADM command line interface, run the "racadm jobqueue view -i <job id>" command to view the status of the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC1138

Message
Unable to export the diagnostics results because the results do not exist.
Detailed Description
Unable to export the remote diagnostics results because the remote diagnostics results have not been generated.
Recommended Response Action
Using the RACADM command line interface, run the "racadm diagnostics run" command to make sure that the diagnostics results are available, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1139

Message
The entered option is not supported by the interface.
Detailed Description
The requested file can be exported from the firmware racadm only to a remote file share.
Recommended Response Action
Create a remote file share to export the file or use remote or local racadm to export to the file system that is accessible by the racadm executable.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1140

Message
File name is not required to export the Technical Support Report (TSR) to a remote share.
Detailed Description
The file name cannot be specified when the Technical Support Report (TSR) is exported to a remote share.
Recommended Response Action
Run the command without using the -f option. For more information on exporting Technical Support Report (TSR), run the command racadm help techsupreport export.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1141

Message
The iDRAC firmware rollback operation was initiated.
Detailed Description
The iDRAC firmware rollback operation was initiated.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1142

Message
Unable to start the Remote Diagnostics operation because the Expiration Time entered (difference between Start Time and Expiration Time) is less than five minutes.
Detailed Description
The Remote diagnostic operation cannot be performed because the difference between "Start Time" and "Expiration Time" is less than 5 minutes.
Recommended Response Action
Make sure that the Expiration Time is greater than five minutes, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1143

Message
Configuration results are not applicable for the job type for Job: arg1 .
Arguments
arg1 = job ID
Detailed Description
The job identified in the message is not a configuration job, a configuration XML import or preview type job that generates configuration results.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1144

Message
The Job: arg1 is invalid or is not present in the job queue and a related Lifecycle Log entry is not found.
Arguments
arg1 = job ID
Detailed Description
No configuration results information is available for the job ID identified in the message because the job ID is invalid or is not present in the job queue and a related Lifecycle Log entry is not found.
Recommended Response Action
Check the job ID identified in the message and retry the operation with a valid job ID. To check valid job IDs in the current job queue, using RACADM, run the command "racadm jobqueue view".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1145

Message
The entered log type is invalid.
Detailed Description
The value entered for the -t option is invalid.
Recommended Response Action
Check help text for the list of valid log types and retry the operation by entering a valid log type.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1146

Message
Unable to set the SNMPv3 username because SNMPv3 is not enabled for the specified user on iDRAC.
Detailed Description
The SNMPv3 username cannot be set because SNMPv3 is not enabled for the specified user on iDRAC.
Recommended Response Action
Enable SNMPv3 for the specified user by running the command "racadm set iDRAC.Users.<user index>.SNMPv3Enable 1", and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1147

Message
Unable to set the SNMPv3 username entered in the command because the username is not present or enabled on iDRAC.
Detailed Description
The SNMPv3 user cannot be set because the user with the entered username for the SNMPv3 group is not present or enabled on iDRAC.
Recommended Response Action
Make sure the specified username is present on iDRAC and enabled, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1150

Message
Unable to complete the export operation.
Detailed Description
The export operation did not be complete successfully.
Recommended Response Action
Retry the export operation after five minutes.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1151

Message
The export operation is unsuccessful.
Detailed Description
The export operation did not complete successfully.
Recommended Response Action
Run the RACADM techsupreport collect command again and then retry the export operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1152

Message
The export operation completed successfully.
Detailed Description
The export operation completed successfully.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1153

Message
The time stamp is not available to display.
Detailed Description
The time stamp was not recorded for the previous techsupreport collect operation.
Recommended Response Action
Run the RACADM techsupreport collect command. After the techsupreport collect operation completes, run the RACADM getupdatetime command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1154

Message
The requested operation is initiated.
Detailed Description
The requested techsupreport collect or export operation is initiated.
Recommended Response Action
Run the RACADM jobqueue sub-command, using the job id to check the status of the requested operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1155

Message
Unable to complete the operation because Lifecycle Controller is disabled.
Detailed Description
The operation was not completed because Lifecycle Controller is disabled.
Recommended Response Action
Enable the Lifecycle Controller and retry the operation. To enable Lifecycle Controller, run the command racadm set LifeCycleController.LCAttributes.LifecycleControllerState 1.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1156

Message
Unable to display the information about the server network interfaces.
Detailed Description
The server network interface information cannot be received because the iDRAC Service Module is not installed or not runing on the server operating system (OS) or collection of the OS data is disabled.
Recommended Response Action
Run the command racadm get iDRAC.ServiceModule to check if iDRAC Service Module is installed and running on the server operation system, and the collection of the OS data is enabled.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1157

Message
Unable to find the specified FQDD.
Detailed Description
The specified FQDD is invalid.
Recommended Response Action
Verify whether or not the entered FQDD is valid. Run the command racadm gethostnetworkinterfaces for the list of valid FQDDs.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1158

Message
The requested number of log entries exceeds the limit.
Detailed Description
The requested number of Lifecycle log entries exceed the limit and cannot be displayed. The remote RACADM operation may time out before retrieving all the log entries.
Recommended Response Action
Retrieve a smaller number of log entries using remote RACADM or use firmware or local RACADM to view all the log entries. To retrieve a limited number of log entries, use the -n option. For example, to view the last 10 log entries, run the command racadm lclog view -n 10.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1159

Message
Unable to get the requested data from iDRAC.
Detailed Description
The data cannot be retrieved from iDRAC because Lifecycle Controller is disabled or a DUP update is in progress.
Recommended Response Action
Do the following: 1) Check if a DUP fw update is progress and wait until it is finished. 2) Make sure the Lifecycle Controller is Enabled. To enable Lifecycle Controller, run the command racadm set LifeCycleController.LCAttributes.LifecycleControllerState 1. 3) Retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1160

Message
Unable to set USB group objects because of insufficient privilege for user account arg1 .
Arguments
arg1 = username
Detailed Description
Unable to set USB group objects because the user account identified in the message does not have the System Control privilege, which is required for this operation.
Recommended Response Action
Contact the iDRAC system administrator and get the System Control privilege added to the account identified in the message or use account credentials that have System Control privilege and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1161

Message
Unable to initiate the techsupreport collect operation for the Tech Support Report (TSR) because the iDRAC Service Module (iSM) is not running.
Detailed Description
Unable to initiate the techsupreport collect operation because the iDRAC Service Module (iSM) is not running.
Recommended Response Action
Run the command racadm get iDRAC.ServiceModule to make sure that iDRAC Service Module is installed and running on the server operation system (OS) and also to verify that the collection of the server OS data is enabled.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1162

Message
Unable to initiate the techsupreport collect operation for the Tech Support Report (TSR) because another collect operation is in progress.
Detailed Description
The requested techsupreport collect operation cannot be initiated because another techsupreport collect operation for the Tech Support Report (TSR) is in progress.
Recommended Response Action
Wait for the current collect operation to complete before initiating another collect operation. To view the status of the techsupreport collect operation, run the command racadm jobqueue view.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1163

Message
The peak utilization value of out-of-band performance monitoring sensor arg1 is successfully reset.
Arguments
arg1 = sensor name
Detailed Description
The peak utilization value of out-of-band performance monitoring sensor identified in the message is successfully reset.
Recommended Response Action
No response action required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1164

Message
A remote diagnostics operation is currently running and not completed.
Detailed Description
A remote diagnostics operation is already under execution and another operation can be started only after the current execution is completed.
Recommended Response Action
Initiate another diagnostics operation only after the currently running operation is completed.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1165

Message
Unable to configure the port number that is entered for either http or https ports of the iDRAC Web server, because the port number is already in use.
Detailed Description
Unable to configure the port number that is entered for either http or https ports of the iDRAC Web server, because the port number is already in use.
Recommended Response Action
Enter a port number that is not already in use and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1166

Message
Successfully initiated Configuration XML file preview operation that was invoked by arg1 .
Arguments
arg1 = user name
Detailed Description
The Configuration XML file preview operation was successfully initiated after it was invoked by the user name identfied in the message.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC1168

Message
The RACADM "getconfig" command will be deprecated in a future version of iDRAC firmware.
Detailed Description
The RACADM "getconfig" command will be deprecated in a future version of iDRAC firmware.
Recommended Response Action
Run the RACADM "racadm get" command to retrieve the iDRAC configuration parameters. For more information on the get command, run the RACADM command "racadm help get".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1169

Message
The RACADM "config" command will be deprecated in a future version of iDRAC firmware.
Detailed Description
The RACADM "config" command will be deprecated in a future version of iDRAC firmware.
Recommended Response Action
Run the RACADM "racadm set" command to configure the iDRAC configuration parameters. For more information on the set command, run the RACADM command "racadm help set".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1170

Message
Unable to find the SSL library in the default path.
Detailed Description
Unable to find the SSL library. This can be because, the library is not installed in the default path or no SSL library is installed.
Recommended Response Action
If a SSL library is not installed, install one and retry the operation. If a SSL library is installed, create a soft-link of the installed SSL library to "libssl.so" using the linux "ln" command and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1175

Message
Unable to change the user configuration because modifying the user configuration at index 1 is not allowed.
Detailed Description
The user configuration cannot be modified, because modification is not allowed at index 1.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1176

Message
Unable to generate the Certificate Signing Request (CSR) message because all the attributes in the iDRAC.Security group are not configured.
Detailed Description
The Certificate Signing Request (CSR) message cannot be generated because all the attributes in the iDRAC.Security group are not configured.
Recommended Response Action
Make sure that all the attributes in the iDRAC.Security group are configured. To get the list of attributes, run the following command "racadm get iDRAC.Security".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1177

Message
A USB device is attached to the iDRAC.
Detailed Description
A USB device is attached to the iDRAC and accessible from the iDRAC.
Recommended Response Action
No response action is required. To attach the USB device to the server instead of the iDRAC, remove the USB device from the front panel USB port, change the USB Management Port mode settings and then reinsert the USB device.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1178

Message
A USB device is attached to the iDRAC and a configuration XML import operation is in progress.
Detailed Description
A USB device is attached to the iDRAC and a configuration XML import operation is in progress.
Recommended Response Action
Wait until the configuration XML import operation has completed before attempting another operation. Verify the status of the configuration XML import operation by running the RACADM command "racadm jobqueue view".
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1179

Message
Unable to complete requested operation because an Type A/A USB cable is connected to the front panel USB port and the iDRAC is emulating a NIC device.
Detailed Description
Unable to complete requested operation because a Type A/A USB cable is connected to the front panel USB port and the iDRAC is emulating a NIC device.
Recommended Response Action
To change the USB Management Port mode setting, remove the Type A/A USB cable from the front panel USB port and change the port mode settings.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1180

Message
A USB device is inserted in the front panel USB Management port and is in use by the server operating system.
Detailed Description
A USB Device inserted in the front panel USB Management port and is in use by the server operating system. The device needs to not be in use in order to change the port mode settings.
Recommended Response Action
Remove and reinsert the USB device and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1181

Message
Unable to change USB Management Port mode.
Detailed Description
USB Management Port state cannot be changed because of an unknown hardware or firmware issue.
Recommended Response Action
To change the Management Port mode settings do the following: If a device is present, remove and reinsert the USB device from the front panel USB Mangement port and retry the operation. If the issue persists restart the iDRAC and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1182

Message
Unable to retrieve information for the Power group or attribute because the server is not PMBus capable.
Detailed Description
The server instrumentation can not provide any information related to power because PMBus capability is not present or the PSU(s) with PMBus capability have been removed.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1183

Message
Unable to assign IP addresses 169.254.0.3 and 169.254.0.4 to the device OSBMC USBNIC because the IP addresses entered are reserved for the iDRAC Direct feature.
Detailed Description
The IP addresses 169.254.0.3 and 169.254.0.4 cannot be assigned to the device identified in the message because the IP addresses entered are reserved for the iDRAC Direct feature.
Recommended Response Action
Enter another appropriate IP address, and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1184

Message
The getuscvresion RACADM subcommand will be deprecated in a future release.
Detailed Description
The getuscvresion RACADM subcommand will be deprecated in a future release.
Recommended Response Action
Instead of getuscversion, run the getversion -f lc subcommand.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1185

Message
Unable to configure static IPv6 address because an invalid IPv6 address or IPv6 Gateway is entered.
Detailed Description
The static IPv6 address is not configured because an invalid IPv6 address or IPv6 Gateway is entered.
Recommended Response Action
Enter a valid IPv6 address and IPv6 Gateway, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1186

Message
1000Mbps speed setting is Read Only and cannot be configured for the iDRAC NIC.
Detailed Description
Only possible configurations for the DRAC NIC are 10Mbps and 100 Mbps. For documentation with respect to this setting, refer to the racadm User Guide under cfgNetTuning group.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC1187

Message
Invalid Start Time Entered. Unable to start the Remote Diagnostics operation because the Start Time entered is earlier than the current iDRAC time.
Detailed Description
The remote diagnostics operation could not be initiated because the Start Time entered is invalid. It is earlier than the current iDRAC time.
Recommended Response Action
Enter a Start Time that is later than the current iDRAC time and retry the operation. Run the "racadm getractime" command to obtain the current iDRAC time.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1188

Message
Unable to configure the Upper Non-Critical value for the System Performance sensor.
Detailed Description
Unable to configure the Upper Non-Critical value for the System Perfromance sensor because the value provided is not in vaild range.
Recommended Response Action
Specify a value in the range of 0 to 100 to set the upper non-critical value.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC1189

Message
Unable to set the object value for iDRAC Service Module.
Detailed Description
The idrac.serviceModule.watchdogtmer object can not be enabled if the OS watch dog timer is already enabled.
Recommended Response Action
Disable the object using "racadm set bIOS.integratedDevices.osWatchdogTimer Disabled " Then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC802

Message
iDRAC time is set using Network Time Protocol.
Detailed Description
iDRAC time has been set through Network Time Protocol (NTP).
Recommended Response Action
No response action is required.
Category
Audit (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RAC913

Message
Unable to login to RAC using the specified address
Detailed Description
The management system could not login to the iDRAC.
Recommended Response Action
Verify whether the username and password given for the iDRAC are correct.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC914

Message
Value specified is invalid: Must be 0 (Off) or 1 (On).
Detailed Description
The specified value is not within the valid range. To set the LED state to off, enter 0. To set the LED state to on, enter 1.
Recommended Response Action
Set the numeric value to 0 (Off) or 1 (On).
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC915

Message
Unable to change auto-negotiation property for the NIC.
Detailed Description
The auto-negotiation property for the iDRAC NIC can be changed only if the NIC is in dedicated mode. To change the NIC mode to dedicated, an iDRAC Enterprise license is required.
Recommended Response Action
Change the NIC mode to dedicated mode by using "racadm set idrac.nic.selection <1 | Dedicated>", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC916

Message
Value given exceeds the maximum threshold value.
Detailed Description
The value given is greater than the maximum threshold value.
Recommended Response Action
Set values lesser than the maximum threshold value. To view the maximum threshold value, run racadm get System.Power. Cap.MaxThreshold at the command prompt.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC917

Message
The syntax of the specified command is not correct.
Detailed Description
The syntax of the specified command is incorrect.
Recommended Response Action
See the command help text. To see the help text, run "racadm help <subcommand>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC918

Message
Unable to get the inlet temperature data.
Detailed Description
Racadm unable to obtain the inlet temperature data. This happens if there is no data populated in the temperature tables or if the underlying instrumentation does not return valid values.
Recommended Response Action
Wait for the underlying instrumentation to populate the thermal tables. Retry the operation.
Category
System Health (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC919

Message
Copy to remote share unsuccessful. Remote share might be write protected.
Detailed Description
Racadm could not export the inlet temperature history file to the specified remote share. This is because the specified share may be write- protected.
Recommended Response Action
To export the file, change the permissions on the remote share. Else, create another share with write permissions.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC920

Message
This interface does not support the specified option.
Detailed Description
From firmware racadm, the inlet temperature history can be exported only to a remote file share.
Recommended Response Action
Create a remote file share to export the inlet temperature history. Else, use remote/local racadm to export to the file system accessible by the racadm executable.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC921

Message
The temperature history can be exported in XML or CSV format only.
Detailed Description
The file type specified (with the t parameter) is invalid. The temperature history can be exported in XML or CSV.
Recommended Response Action
Change the requested export file type to either XML or CSV. To do this, change the argument given to the t parameter. The argument given to the parameter is case-insensitive.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC922

Message
Specified path is too long.
Detailed Description
The specified path (specified with the l parameter) for the remote share is too long. This path should be less than 256 characters in length.
Recommended Response Action
Try the same command with a different remote share location, which is less than 256 characters in length.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC923

Message
The file path is too long.
Detailed Description
The specified file path (specified with the f parameter) is too long. This path should be less than 64 characters in length.
Recommended Response Action
Try the same command with a shorter file path (specified with the f parameter) which is less than 64 characters in length.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC924

Message
Inlet temperature history exported successfully.
Detailed Description
The inlet temperature history was successfully exported to the specified file.
Recommended Response Action
None.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC925

Message
Recurrence interval is not applicable for this subcategory.
Detailed Description
An alert recurrence cannot be set for the specified subcategory. The alert recurrence is applicable only to the TMPS subcategory.
Recommended Response Action
1. Check if the alert recurrence is applicable to this subcategory. To check this run racadm eventfilters get. 2. To set the notifications for the specified subcategory, run the command without the -r option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC926

Message
The recurrence interval needs to be an integer from 0 to 365.
Detailed Description
The value given for the recurrence interval is invalid. It has to be a value from 0 to 365.
Recommended Response Action
Change the argument of r to a value from 0 to 365 and then run the same command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC927

Message
Recurrence value modified successfully.
Detailed Description
The recurrence value was successfully modified to the specified value.
Recommended Response Action
None.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC928

Message
Unable to modify the recurrence value.
Detailed Description
Racadm unable to set the recurrence value. This occurs if the underlying instrumentation do not set the value.
Recommended Response Action
Wait for a few minutes and retry the command. If the problem persists, contact the service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

RAC929

Message
Invalid category or subcategory specified.
Detailed Description
The category or subcategory specified is incorrect. The recurrence interval is applicable only to the TMPS subcategory and system category.
Recommended Response Action
See the command help text, for a list of valid categories.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC930

Message
Unable to export the inlet temperature data.
Detailed Description
Racadm is currently unable to obtain the inlet temperature data. This happens if there is no data populated in the temperature tables or if the instrumentation does not return valid values.
Recommended Response Action
Wait for the instrumentation to populate the thermal tables. Retry the operation. If the problem persists, contact the service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

RAC936

Message
Unable to change the hot spare property for the PSU.
Detailed Description
iDRAC cannot enable or disable the hot spare property, because the system has a non-PMBus PSU.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC937

Message
Successfully initiated configuration XML file import operation that was invoked by the arg1 .
Arguments
arg1 = user name
Detailed Description
The configuration XML file import operation was successfully initiated after it was invoked by the user specified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC938

Message
Successfully initiated configuration XML file export operation invoked by the arg1 .
Arguments
arg1 = user name
Detailed Description
The configuration XML file export operation was successfully initiated after it was invoked by the user specified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

RAC939

Message
Unable to start the system configuration profile export or import operation.
Detailed Description
The request to perform a system profile export or import opeartion cannot be started because a firmware update operation is already in progress.
Recommended Response Action
Wait until the update operation is completed or cancel the update operation, and retry.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC940

Message
Unable to start the system configuration profile export or import operation.
Detailed Description
If an existing system profile import or export job is running, then a system configuration profile backup or restore opeartion cannot be started.
Recommended Response Action
Wait until the existing system profile export or import job is completed or cancel the job before retrying the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC941

Message
Successfully initiated the export operation. This operation may take several minutes to complete.
Detailed Description
A system configuration profile export operation may take several minutes to complete depending on the system configuration.
Recommended Response Action
Monitor the job status using "racadm jobqueue view -i <Job ID>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC942

Message
Successfully initiated the import operation. This operation may take several minutes to complete and may cause multiple system restarts while device firmware and configuration are applied.
Detailed Description
The system configuration profile import operation is initiated. No other operations can be performed on the system while the system configuration server profile is being imported from the system configuration profile.
Recommended Response Action
Monitor the job status using "racadm jobqueue view -i <Job ID>".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC943

Message
Warning: Collect System Inventory On Restart (CSIOR) feature is disabled.
Detailed Description
The Collect System Inventory On Restart (CSIOR) feature is currently disabled. If the system inventory is not up-to-date, the system configuration profile that is being copied will not have the latest inventory information.
Recommended Response Action
To get latest inventory information, cancel the current export job, run "racadm set LifecycleController.LCAttributes.CollectSystemInventoryOnRestart 1" to enable CSIOR, and re-initiate the export operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC944

Message
Unable to create the configuration job.
Detailed Description
A configuration job cannot be created if Lifecycle Controller is disabled.
Recommended Response Action
Run "racadm set LifecycleController.LCAttributes.LifecycleControllerState 1" to enable Lifecycle Controller, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC945

Message
Invalid object value specified.
Detailed Description
The dedicated NIC or shared NIC scan time value is not between 5 and 255 seconds.
Recommended Response Action
Make sure to set the scan time value between 5 and 255 seconds, and retry the operation. For more information, see RACADM help.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC946

Message
Unable to set the NIC to Auto Dedicated NIC mode.
Detailed Description
The "Auto Dedicated NIC" mode cannot be set for a NIC if the NIC selection mode is set to "Dedicated NIC".
Recommended Response Action
To set the NIC to Auto Dedicated NIC mode, set NIC selection mode to "Shared NIC", and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC947

Message
Invalid object value specified.
Detailed Description
The value used for the object set operation is invalid.
Recommended Response Action
Make sure to specify the value depending on the type of object. For more information, see RACADM help.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC948

Message
Unable to send the notification for the specified event to the configured destination.
Detailed Description
A test event notification for the specified message ID was not sent to the configured destination.
Recommended Response Action
Make sure to the use a valid message ID, set the required notification filter, and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC949

Message
Successfully added a work note to the Lifecycle Log.
Detailed Description
The specified work note was added to the Lifecycle Log.
Recommended Response Action
View the work notes using the racadm lclog view c worknotes command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC950

Message
Unable to add the work note to the Lifecycle Log.
Detailed Description
The work note cannot be added to the Lifecycle Log if iDRAC is archiving the older records in the Lifecycle Log.
Recommended Response Action
Wait for several minutes while iDRAC archives the older records, and then retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC951

Message
The number of characters entered for the work note exceeds the supported limit.
Detailed Description
Up to 256 characters are allowed for a work note.
Recommended Response Action
Do not exceed 256 characters in the work note, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC952

Message
There is no free space to add new work notes to the Lifecycle Log.
Detailed Description
The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further work notes can be added to the Lifecycle Log.
Recommended Response Action
Contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC953

Message
Successfully added the comment.
Detailed Description
The comment was added to the specified entry in the Lifecycle Log.
Recommended Response Action
View the added comment using the racadm lclog view q <seq. no> -n 1 command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC954

Message
The number of characters entered for the comment exceeds the supported limit.
Detailed Description
Up to 128 characters are allowed for a comment.
Recommended Response Action
Do not exceed 128 characters for the comment, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC955

Message
Unable to retrieve the information related to the specified record in the Lifecycle Log.
Detailed Description
The specified record does not exist in the Lifecycle Log.
Recommended Response Action
Run the racadm lclog view -i command to get the sequence number of the records logged in the Lifeycle Log, and retry the command with a valid sequence number.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC956

Message
There is no free space to add new comments to the Lifecycle Log.
Detailed Description
The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further comments can be added to the Lifecycle Log.
Recommended Response Action
Contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC957

Message
An import or export operation is currently in progress.
Detailed Description
Another import or export operation cannot be started until the current operation is complete.
Recommended Response Action
Wait until the current import or export operation is complete before starting another operation. Use the racadm jobqueue view command to check the status of the current import or export operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC958

Message
Unable to start the import or export operation.
Detailed Description
An import or export operation cannot be started until the current running job is complete.
Recommended Response Action
Wait for the current running job to complete before starting another operation. Current job running can be update or backup or file export or similar job. Use the racadm jobqueue view command to check the status of the current update operation jobs.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC959

Message
Invalid file used for configuration XML file import operation.
Detailed Description
The content of the configuration XML file used for import is invalid because of incorrect modifications or content.
Recommended Response Action
Correct the modifications to the configuration XML file to be imported or specify the correct file, and retry the operation. Check the Lifecycle Log for more details.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC960

Message
Unable to find the specified configuration XML file for import.
Detailed Description
The configuration XML file specified for import cannot be located in the specified repository.
Recommended Response Action
Make sure the specified file name is correct and is located in the specified repository, and retry the operation. For more information about the syntax, run "racadm help set" to view RACADM help.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC961

Message
A pending or committed system configuration change exists.
Detailed Description
Another import operation cannot be started if an import operation that was performed earlier has some pending or commited configuration changes.
Recommended Response Action
Wait until the configuration changes are applied before starting another import operation. Use the racadm jobqueue view command to check the status of the current import operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC962

Message
Unable to continue with the operation because Lifecycle Controller is in recovery state,
Detailed Description
Lifecycle Controller must be enabled to run the operation.
Recommended Response Action
Enable the Lifecycle controller using the racadm set LifeCycleController.LCAttributes.LifecycleControllerState 1 command, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC963

Message
Unable to retrieve the status of Lifecycle Controller.
Detailed Description
iDRAC is unable to read Lifecycle Controller status. Lifecycle Controller must be enabled to run the operation.
Recommended Response Action
Run the racadm get LifeCycleController.LCAttributes.LifecycleControllerState command to get the status of the Lifecycle Controller. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC964

Message
Unable to perform the operation.
Detailed Description
The operation cannot be performed because of an internal error.
Recommended Response Action
Wait for some time before retrying the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC965

Message
The -l option must be specified if -u and -p are used.
Detailed Description
Any operation involving remote share (CIFS) cannot continue if the location (-l) is not specified. The u and p options represent the user name and password for the remote share, and -l represents the location of the remote share.
Recommended Response Action
Make sure to specify the location (-l) of the remote share along with the user name and password, and retry the operation. To view the list of options that can used for the required subcommand, use the racadm help <subcommand> command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC966

Message
Unable to continue with the opearion because the user name or password is not specified.
Detailed Description
Any operation involving remote share (CIFS) cannot continue if user name, password, or both are not specified. The u and p options represent the user name and password for the remote share.
Recommended Response Action
Make sure to specify both user name and password for the remote share, and retry the operation. To view the list of options that can used for the required subcommand, use the racadm help <subcommand> command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC967

Message
Exporting the configuration XML file to a local share is not supported when using Firmware RACADM.
Detailed Description
The configuration XML file can only be exported to a remote share while using Firmware RACADM.
Recommended Response Action
When using Firmware RACADM, make sure to export the configuration XML file to a remote share only.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC968

Message
Importing the configuration XML file from a local share is not supported when using Firmware RACADM.
Detailed Description
The configuration XML file cannot be imported from a client location when using Firmware RACADM.
Recommended Response Action
When using Firmware RACADM, make sure to import the configuration XML file from a remote share only.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC969

Message
Incorrect value specified for the shutdown option.
Detailed Description
The import operation cannot continue if the value specified for the shutdown option (-b) is incorrect. The supported values are "Graceful" and "Forced".
Recommended Response Action
Make sure to specify either "Graceful" or "Forced" for the shutdown (-b) option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC970

Message
Incorrect value specified for the end power state option.
Detailed Description
The import operation cannot continue if the value specified for the end power state of the system option (-s) is incorrect. The supported values are "On" and "Off".
Recommended Response Action
Make sure to specify either "On" or "Off" for the end power state (-s) option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC971

Message
Incorrect file type specified.
Detailed Description
The import or export operation cannot continue if the value specified for the file type is incorrect. The correct value for the file type is "xml" or "ini".
Recommended Response Action
Make sure to specify either "xml" or "ini" for the file type (-t) option. If no file type is specified, "ini" is used as default.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC972

Message
Insufficient privileges to run the configuration XML file import or export operations.
Detailed Description
Configuration XML import and export operations require the specified username to have administrator role privileges.
Recommended Response Action
Run the same command with a username that has an administrator role privileges.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC973

Message
The imported configuration XML file matches the current system configuration.
Detailed Description
The configuration XML file which was specified for import, had the same configuration as the current system configuration.
Recommended Response Action
Make any desired system configuration changes to the configuration XML file and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC974

Message
Invalid wait time specified.
Detailed Description
The value specified for the wait time (w) option is invalid. The valid range is 300 to 3600 seconds.
Recommended Response Action
Make sure to specify a valid wait time (-w) option and retry the command. The range of supported values are 300 to 3600 seconds.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC975

Message
Invalid share type specified.
Detailed Description
The share type specified using the l parameter is invalid. Only CIFS or NFS share types are supported for this operation.
Recommended Response Action
See the subcommand help text for supported share types.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC976

Message
Export configuration XML file operation initiated.
Detailed Description
The configuration XML file export operation was initiated.
Recommended Response Action
Use the racadm jobqueue view i <Job ID> command to view the status of the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC977

Message
Import configuration XML file operation initiated.
Detailed Description
The configuration XML file import operation was initiated.
Recommended Response Action
Use the racadm jobqueue view i <Job ID> command to view the status of the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC978

Message
Unsupported Lifecycle Controller firmware version detected.
Detailed Description
The Lifecycle Controller firmware version on the target system does not support the configuration XML file import or export operations.
Recommended Response Action
Update to the latest Lifecycle Controller firmware and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC979

Message
Successfully uploaded the custom signing certificate to iDRAC.
Detailed Description
The custom signing certificate was extracted from the Public Key Cryptography Standards version 12 (PKCS12) file and applied to the system configuration.
Recommended Response Action
No response action required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC981

Message
The type of certificate specified does not require a passphrase.
Detailed Description
A passphrase is required only for passphrase protected certificate, which is specified using the value of 3 for the -t option.
Recommended Response Action
If the file being uploaded is passphrase protected, specify the file type as 3 using the -t option. If the file is not passphrase protected, retry the command, without specifying the -p option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC982

Message
Invalid Public Key Cryptography Standards version 12 (PKCS12) file detected.
Detailed Description
The PKCS12 file provided is invalid, because it may not be in the correct format.
Recommended Response Action
For more details, contact the Certificate Authority.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC983

Message
Invalid passphrase provided for the Public Key Cryptography Standards version 12 (PKCS12) file.
Detailed Description
The Public Key Cryptography Standards version 12 (PKCS12) file is passphrase protected, and the passphrase provided is invalid.
Recommended Response Action
Specify the correct passphrase for the file using -p option.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC984

Message
Unable to upload the Public Key Cryptography Standards version 12 (PKCS12) file.
Detailed Description
iDRAC is unable to extract the custom signing certificate and the private key from the Public Key Cryptography Standards version 12 (PKCS12) file.
Recommended Response Action
Check if the specified file and passphrase are valid, and retry the operation. If the issue persists, contact your service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC985

Message
Unable to configure the cfgServerBootOnce object.
Detailed Description
The object "cfgServerBootOnce" cannot be configured if the object "cfgServerFirstBootDevice" is set to F10, F11, or BIOS value.
Recommended Response Action
Change the value of the object "cfgServerFirstBootDevice" using the RACADM command "racadm config -g cfgServerInfo -o cfgServerFirstBootDevice<value other than F10, F11, and BIOS>", and retry configuring the object "cfgServerBootOnce".
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC986

Message
The "vmkey" sub-command is deprecated.
Detailed Description
The "vmkey" sub-command is deprecated, and the functionality is available using "vflashsd" sub-command.
Recommended Response Action
Use "vflashsd" sub-command instead of "vmkey". For more information about the sub-command, use "racadm help vflashsd" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC987

Message
Firmware update job for arg1 is initiated.
Arguments
arg1 = file name
Detailed Description
After initiating the firmware update job, the time taken to complete it depends on size of the update file.
Recommended Response Action
This firmware update job may take several minutes to complete depending on the component or firmware being updated. To view the progress of the job, use the "racadm jobqueue view" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC988

Message
Unable to initiate the arg1 firmware update.
Arguments
arg1 = file name
Detailed Description
A new firmware update job cannot be initiated while an existing firmware update job is still in one of these states: "New", "Downloading", or "Running".
Recommended Response Action
Wait until the existing firmware update jobs are completed or scheduled before retrying the operation. To monitor the status of the existing jobs, use the "racadm jobqueue view" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC989

Message
Unable to apply the arg1 firmware update.
Arguments
arg1 = file name
Detailed Description
Only Windows-based Update Package (.exe extension), iDRAC Firmware (.d7 extension), Personality Module Firmware (.pm extension), Lifecycle Controller firmware repair package (.usc) are supported for the firmware update operation.
Recommended Response Action
The file used for the operation is invalid. For the list of supported files, use "racadm help update". For the correct version of the file specific to the system, contact the service provider.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC990

Message
Unable to apply the arg1 update.
Arguments
arg1 = file name
Detailed Description
If Lifecycle Controller is disabled, the firmware update operation cannot continue.
Recommended Response Action
Enable Lifecycle Controller using the "racadm set lifecyclecontroller.lcattributes.lifecyclecontrollerstate 1" command, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC991

Message
Unable to run the "jobqueue" command.
Detailed Description
The "jobqueue" command cannot be run, because the existing update jobs are transitioning to one of these states: "New", "Downloading", or "Running".
Recommended Response Action
Wait until the existing update jobs are completed before retrying the operation. To monitor the status of the existing jobs, use the "racadm jobqueue view" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC992

Message
Invalid job: arg1 .
Arguments
arg1 = job ID
Detailed Description
The job ID specified in the message is invalid or was already deleted.
Recommended Response Action
To monitor the current set of the jobs, use the "racadm jobqueue view" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC993

Message
The job: arg1 was deleted.
Arguments
arg1 = job ID
Detailed Description
The job ID specified in the message was deleted.
Recommended Response Action
No response action is required.
Category
Configuration (RAC = RAC Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC994

Message
Unable to run the "jobqueue delete --all" command.
Detailed Description
The jobs cannot be deleted if they are in one of these states: "Scheduled" or "Running". However, all jobs in one of these states: "Completed" or "Failed" will be deleted.
Recommended Response Action
To monitor the job status, use the "racadm jobqueue view -i <job ID>", and delete the jobs one at a time using the "racadm jobqueue delete -i <job ID>" command.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC995

Message
Unable to retrieve the hardware inventory.
Detailed Description
The hardware inventory cannot be retrieved because another hardware inventory operation may already be in progress or due to an internal error whether or not Collect System Inventory On Restart (CSIOR) is enabled or disabled.
Recommended Response Action
Another hardware inventory operation may already be in progress and must complete before retrying the operation. If no other hardware inventory operation was in progress, make sure to enable Collect System Inventory On Restart (CSIOR) feature, reboot the system, and retry the operation. If CSIOR is already enabled and no other hardware inventory operation was in progress, reboot the iDRAC using "racadm racreset" command and then retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC996

Message
Unable to set the object value because the DNS RAC Name object is not configured.
Detailed Description
Unable to set the specified object value because the object DNS RAC Name is not configured.
Recommended Response Action
Configure DNS Rac Name using "racadm set iDRAC.NIC.DNSRacName <Name>" command, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC997

Message
The object DNSDomainFromDHCP cannot be enabled.
Detailed Description
The DHCP for Domian Name cannot be enabled if IPv4 and IPv4 DHCP or IPv6 and IPv6 AutoConfig is disabled.
Recommended Response Action
Make sure that IPv4 and IPv4 DHCP are enabled, or IPv6 and IPv6 AutoConfig are enabled.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC998

Message
IPv6 cannot be enabled.
Detailed Description
IPv6 cannot be enabled if iDRAC NIC is disabled.
Recommended Response Action
Enable iDRAC NIC using "racadm set iDRAC.NIC.Enable < 1 | Enabled >" command and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

RAC999

Message
The object DNSFromDHCP6 cannot be enabled.
Detailed Description
DNSFromDHCP6 cannot be enabled if iDRAC IPv6 AutoConfig is disabled.
Recommended Response Action
Enable IPv6 AutoConfig using "racadm set iDRAC.IPv6.AutoConfig < 1 | Enabled >" command, and retry the operation.
Category
Configuration (RAC = RAC Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\