IOV Event Messages

IOV000

Message
Successfully completed the operation.
Detailed Description
This operation was successful.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV001

Message
The operation contains an invalid request or argument.
Detailed Description
The operation or operation parameter sent to the Chassis Manager is invalid or not supported.
Recommended Response Action
Contact technical support. Refer to Chassis Manager product documentation to determine the contact method for the service provider.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV002

Message
Unable to create or allocate the required resources.
Detailed Description
CMC could not successfully allocate resources because of the following reasons: 1) The chassis manager is unable to allocate required resources. 2) The chassis manager or chassis infrastructure firmware is rolled back to an earlier version. 3) There is an issue with the internal communications between chassis components.
Recommended Response Action
Make sure the firmware for the various chassis components are compatible with each other. If this is the case, do the following: 1) Turn off the chassis, by pressing the chassis Power Button, 2) run the following CMC RACADM command "racadm racresetcfg". If the problem persists, contact your technical service provider.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV003

Message
Unable to manage the device located in the PCIe slot specified in the operation.
Detailed Description
A PCIe device error was detected that does not allow the assignment, unassignment, or the turning off of the device. The errors can be caused by incorrect PCIe device installation or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
Recommended Response Action
Make sure that supported adapters are used and installed correctly in the PCIe slots.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV004

Message
Unable to turn on PCIe adapter.
Detailed Description
The chassis manager is unable to turn on the PCIe device because of one of the following reasons: 1) PCIe device is not supported, 2) The device is not properly inserted in the slot, 3) The device is not functioning properly, or 4) The device power requirements exceed the power available for the slot.
Recommended Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, contact the service provider.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV005

Message
Chassis Management Controller (CMC) is not ready to run commands.
Detailed Description
The Chassis Management Controller is not ready to run commands because the chassis must be turned on.
Recommended Response Action
Turn on chassis and retry the command.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV006

Message
Incorrect Chassis Infrastructure Mainboard firmware version.
Detailed Description
The Chassis Infrastructure Mainboard firmware is not at the correct version..
Recommended Response Action
Run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV007

Message
Chassis Management Controller (CMC) is unable to allocate power to one or more PCIe adapters in the Chassis Infrastructure component.
Detailed Description
For each adapter assigned to a server, power is allocated when the server is turned on. If the available power is less than the required power, the Chassis Management Controller (CMC) will not power on the adapters associated with the server.
Recommended Response Action
To release the required power, turn off one or more servers by pressing the Power Button on the individual server units.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV008

Message
Chassis Management Controller (CMC) is unable to put PCIe subsystem into factory default mode.
Detailed Description
The Chassis Management Controller (CMC) was unable to reset the PCIe subsystem into factory default mode.
Recommended Response Action
Turn off the chassis, turn on the chassis, and then retry the operation.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV009

Message
Chassis Management Controller (CMC) is unable to reset to factory default or pre-factory default settings.
Detailed Description
The Chassis Management Controller (CMC) runs this function only when the chassis is turned off.
Recommended Response Action
Turn off the chassis and retry the operation.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV010

Message
Unable to assign the PCIe slot(s) because a license is required to assign more than two PCIe slots to a server.
Detailed Description
Unable to assign the PCIe slots because a license is required to assign more than two PCIe slots to a server. Non-licensed systems are allowed only two slots per server.
Recommended Response Action
Import a license that allows assignments of more than two PCIe slots per server. For more information about licenses, contact your service provider.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV011

Message
Unable to assign or unassign PCIe slot(s) or virtual adapter (VA) because all affected servers must be turned off.
Detailed Description
All servers that PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from must be turned off before an assign or unassign operation can be performed.
Recommended Response Action
Turn off all servers that the PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from, and then retry the operation.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV012

Message
Unable to assign a virtual adapter (VA) to a non-default server because a license is required.
Detailed Description
By default, the non-licensed system assigns virtual adapters (VA) 1-4 to servers 1-4 respectively.
Recommended Response Action
Import a license which enables the assignment of a PERC virtual adapter (VA) to any server. For more information about licenses, contact your service provider.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV013

Message
Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA.
Detailed Description
Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA.
Recommended Response Action
Unassign the servers current virtual adapter (VA) and retry the operation. To unassign the VA using RACADM, run the following command "racadm setpciecfg".
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV014

Message
The external shared storage device is not ready because the initialization process is still incomplete.
Detailed Description
The external shared storage device is not ready because the initialization process is still incomplete.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV015

Message
Unable to map/un-map or turn on the external shared adapter because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest version supporting the adapter.
Detailed Description
The external shared adapter cannot be turned on until the Chassis Intfrasture firmware is updated to the latest version supporting the shared adapter.
Recommended Response Action
Remove the adapter or update the Chassis Infrastructure firmware and then retry the operation. Using the Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV016

Message
Only the virtual adapters (VA) of a shared adapter may be assigned to or unassigned from a server.
Detailed Description
The shared adapter may not be assigned to or unassigned from a blade-server. Only the virtual adapters (VA) of a shared adapter may be assigned to or unassigned from a server.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

IOV1001

Message
The requested operation was successfully executed.
Detailed Description
The requested operation was successfully executed.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

IOV1002

Message
The operation was not successful.
Detailed Description
The operation did not complete successfully due to an exception from the instrumentation layer.
Recommended Response Action
Retry the operation. If the issue persists, reset CMC and retry the operation when the CMC has completed restarting. The CMC may take 2 to 3 minutes to complete restarting.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

IOV1003

Message
Missing required parameter arg1 .
Arguments
arg1 = parameter name
Detailed Description
One or more parameters identified in the message required for the method are missing.
Recommended Response Action
Refer to the DCIM Chassis PCI Management Profile document and provide the required parameter.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1004

Message
Too many slots provided as parameters to Assign and UnAssign Servers methods.
Detailed Description
The parameters for the method identified in the message are not passed correctly.
Recommended Response Action
Refer to the DCIM Chassis PCI Management Profile document and provide the required parameters.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1005

Message
Invalid slot FQDD arg1 .
Arguments
arg1 = FQDD value
Detailed Description
The FQDD (Fully Qualified Device Descriptor) entered for the operation does not map to any instance of the DCIM_ChassisPCISlot class.
Recommended Response Action
Perform the Enumerate operation on the DCIM_ChassisPCISlot class to determine the correct FQDD value for the required slot. Retry the operation with the correct FQDD value.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1006

Message
Invalid PCI slot or Server slot.
Detailed Description
The PCI slot or Server slot FQDD (Fully Qualified Device Descriptor) values entered for the operation are not valid.
Recommended Response Action
Perform the Enumerate operation on the DCIM_ChassisPCISlot class and DCIM_BladeServerView class to get the correct FQDD values for the PCIe slot and Server slot. Retry the operation with the correct FQDD values.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1007

Message
Unable to assign a PCIe slot.
Detailed Description
The IOV slot management subsystem detected an error which may prevent the physical assignment/unassignment or turning off of a PCIe slot. The errors can be caused by PCIe training timeouts, false hot plug signals,or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
Recommended Response Action
Insert only supported adaptor cards into system PCIe slots and make sure they are fully inserted. Retry the operation.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1008

Message
Invalid Virtual Adapter FQDD arg1 .
Arguments
arg1 = FQDD value
Detailed Description
The FQDD (Fully Qualified Device Descriptor) value entered for the operation does not map to any DCIM_ChassisVAView class instance representing Virtual Adapters.
Recommended Response Action
Perform an Enumerate operation on the DCIM_ChassisVAView class to get the correct FQDD for the Virtual Adapter. Retry the operation with the correct FQDD value.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV1009

Message
Mismatch in Slot or Virtual Adapter FQDD and Server Slot FQDD count.
Detailed Description
The FQDD pairs identified in the messages do not match in the required method input parameters.
Recommended Response Action
Provide a valid pair of FQDDs. Please refer to the DCIM Chassis PCI Management Profile document for the required parameter definitions.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

IOV101

Message
A PCIe adapter arg1 is inserted in arg2 arg3 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed Description
The Chassis Management Controller (CMC) detected the insertion of an adapter in the slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV102

Message
A PCIe adapter arg1 is removed from arg2 arg3 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed Description
The Chassis Management Controller (CMC) detected the removal of an adapter card from the slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV103

Message
A PCIe adapter arg1 in arg2 arg3 is replaced by PCIe adapter arg4 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number, arg4 = device name
Detailed Description
The Chassis Management Controller (CMC) detected the replacement of an adapter in the slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV104

Message
The Chassis Management Controller (CMC) is unable to allocate arg1 Watt for server- arg2 PCIe adapters.
Arguments
arg1 = number of Watt, arg2 = server slot number
Detailed Description
For each adapter assigned to a server, power is allocated when the server is turned on. If the available power is less than the required power, the Chassis Management Controller (CMC) will not power on the adapters associated with the server.
Recommended Response Action
Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional power supply.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
2554
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV105

Message
Unable to manage PCIE adapter arg1 located in arg2 arg3 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed Description
An error by the Chassis Infrastructure slot management detected an error which may prevent the physical assignment/unassignment or power off of a slot. The errors may be caused by PCIE training timeouts, false hot plug signals, or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
Recommended Response Action
Make sure that supported adapters are used and installed correctly in the PCIe slot.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
2554
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV106

Message
Unable to power on PCIe adapter arg1 in arg2 arg3 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed Description
The Chassis Management Controller (CMC) is unable to power on adapter. Possible reasons for power failures are: 1) Adapter not an approved adapter. 2) Adapter not fully inserted in the slot 3) Auxiliary power cable not connected (applicable to slot 1 - 3 only). 4) Adapter is damaged.
Recommended Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, contact the service provider.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
2554
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV107

Message
PCIe adapter arg1 in slot arg2 was removed while powered on.
Arguments
arg1 = device dame, arg2 = slot number
Detailed Description
The Chassis Management Controller (CMC) has detected the removal of a PCIe adapter card while it was powered on.
Recommended Response Action
Power down the affected server(s) and then power on the server(s). Note: OS reboot only will not correct this issue.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
Trap/EventID
2553
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV108

Message
Power fault detected on PCIE adapter arg1 in arg2 arg3 .
Arguments
arg1 = device name, arg2 = slot type, arg3 = slot number
Detailed Description
The Chassis Management Controller (CMC) detected a power fault in an adapter after the adapter was powered on. A power fault may be caused by a damaged adapter or the adapter power requirements exceed the maximum power limits of the slot.
Recommended Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, contact your service provider.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
2554
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*       ✔*

IOV109

Message
An error condition associated with the PCIe slot is cleared.
Detailed Description
An error condition associated with the PCIe slot is cleared.
Recommended Response Action
No response action is required.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC   ✔*         ✔*

IOV110

Message
Successfully updated Chassis Infrastructure firmware.
Detailed Description
Successfully updated Chassis Infrastructure firmware.
Recommended Response Action
No response action is required.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

IOV111

Message
Unable to update Chassis Infrastructure firmware.
Detailed Description
Unable to successfully update Chassis Infrastructure firmware.
Recommended Response Action
Refer to the release notes of the Mainboard update package for recommended action. If the issue persists, contact your service provider.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
Trap/EventID
2553
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

IOV112

Message
Chassis Infrastructure firmware is not valid.
Detailed Description
Chassis infrastructure firmware is not valid and must be reinstalled.
Recommended Response Action
Update the Chassis Infrastructure firmware. Using Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
Trap/EventID
2553
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

IOV113

Message
Chassis Infrastructure firmware re-installation is successful.
Detailed Description
Chassis Infrastructure firmware re-installation is successful.
Recommended Response Action
No response action is required.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*         ✔*

IOV114

Message
arg1 arg2 assigned to server- arg3 .
Arguments
arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server number
Detailed Description
The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the server identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV115

Message
Unable to allocate arg1 WATTS for discovery of PCIE adapters.
Arguments
arg1 = number of watts
Detailed Description
The discovery process for PCIE adapters was unable to allocate the power required to power on the PCIE adapters
Recommended Response Action
Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional power supply.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
10746
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC        
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV116

Message
PCIE AUX power cable arg1 .was disconnected while powered on.
Arguments
arg1 = cable number
Detailed Description
The Chassis Management Controller (CMC) detected a power fault in an PCIE AUX power cable after the adapter was powered on. A power fauilt may be caused by a loose cable connection to the adapter or between the cable and the AUX cable harness.
Recommended Response Action
Make sure AUX power cable identified in the message is fully plugged into the adapter and the AUX cable harness.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
2554
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV117

Message
arg1 arg2 was unassigned/unmapped from server- arg3 .
Arguments
arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server numer
Detailed Description
The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been unassigned/unmapped from the server identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV118

Message
Fabric arg1 is down.
Arguments
arg1 = fabric ID
Detailed Description
The Fabric identified in the message is not up and a chassis power cycle is required.
Recommended Response Action
Power cycle the chassis. Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm chassisaction powercycle".
Category
System Health (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
Trap/EventID
2553
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV119

Message
PCIe ride-through mode is disabled.
Detailed Description
The Chassis Management Controller (CMC) has disabled PCIe ride-through mode. PCIe adapters that are turned on and in "ride-through" mode are immediately turned off.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV120

Message
PCIe ride-through mode is enabled.
Detailed Description
The Chassis Management Controller (CMC) has enabled PCIe ride-through mode. PCIe adapters will remain turned on for the number of seconds specified by the ride-through timeout value after the server they are assigned to is turned off.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV121

Message
PCIe ride-through time out has changed from arg1 to arg2 seconds.
Arguments
arg1 = seconds, arg2 = seconds
Detailed Description
The Chassis Management Controller (CMC) has changed the PCIe ride-through timeout to the value identified in the message. PCIe adapters will remain turned on for the number of seconds specified by the ride-through timeout value after the server they are assigned to is turned off. Note: A value of zero equals infinite number of seconds.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV122

Message
arg1 arg2 is mapped/assigned to extension of server slot arg3 .
Arguments
arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server number
Detailed Description
The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the extension of the server slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*       ✔*

IOV123

Message
arg1 arg2 is unassigned/unmapped from extended server slot arg3 .
Arguments
arg1 = "PCIE Slot" or "PERC VA", arg2 = slot number or VA number, arg3 = server numer
Detailed Description
The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been unassigned/unmapped from the extension of the server slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 3 (Informational)
Trap/EventID
10747
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV124

Message
The PCIe shared adapter in slot arg1 is not supported because the firmware version of the Chassis Infrastructure Mainboard is not the latest.
Arguments
arg1 = slot number
Detailed Description
The PCIe shared adapter in slot identified in the message is not supported because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest.
Recommended Response Action
Remove the adapter or update the Chassis Infrastructure firmware and then retry the operation. Using Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
Category
Configuration (IOV = IO Virtualization)
Severity
Severity 2 (Warning)
Trap/EventID
10746
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔*         ✔*

IOV2008

Message
The Chassis Management Controller (CMC) is unable to communicate with the PCIe subsystem.
Detailed Description
The Chassis Management Controller (CMC) could not successfully connect to the PCIe subsystem.
Recommended Response Action
Do the following: 1) Perform an AC Power Cycle operation on the Chassis by disconnecting the chassis from AC power, wait for 30 seconds, and then reconnect AC power. 2) Turn on at least one server. Using the Chassis Management Controller (CMC) web interface, select Server Overview->Power->Control and select the Power On Server option. If the issue persists, contact your service provider.
Category
System Health (IOV = IO Virtualization)
Severity
Severity 1 (Critical)
Trap/EventID
2553
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC ✔* ✔*         ✔*

Rate this content