FLDC Event Messages

FLDC1001

Message
The journal mirror at path = arg1 is available.
Arguments
arg1 = World Wide Name
Detailed Description
The entry in the journal for the device identified in the message with the WWN (World Wide Name) is available.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2700
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1002

Message
The following journal mirror is being replaced: File Path Name = arg1 .
Arguments
arg1 = file path
Detailed Description
The journal mirror at the reported file path is being replaced. This event is a notification that the journal mirror replacement is now complete.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2701
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1003

Message
Cache flushing has started for the virtual disk with WWN = arg1 and path = arg2 .
Arguments
arg1 = World Wide Name, arg2 = device pathname
Detailed Description
The cache flushing operation has started for the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2875
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1004

Message
Cache flushing has completed for the virtual disk with WWN = arg1 and path = arg2 .
Arguments
arg1 = World Wide name, arg2 = device pathname
Detailed Description
The cache flushing operation has completed for the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2876
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1006

Message
The cache device arg1 with WWN = arg2 and path = arg3 is registered.
Arguments
arg1 = physical disk name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
The cache device identified in the message is registered by the Fluid Cache.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2903
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1007

Message
The cache device arg1 with WWN = arg2 and path = arg3 is removed.
Arguments
arg1 = physical disk Name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
The cache device identified in the message is removed from the Fluid Cache configuration.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2904
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1008

Message
The cache device arg1 with WWN = arg2 and path = arg3 is being removed.
Arguments
arg1 = physical disk Name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
The cache device identified in the message is being removed from the Fluid Cache configuration.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2905
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1009

Message
Caching is being removed for the arg1 with WWN = arg2 and path = arg3 .
Arguments
arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
Caching is being removed for the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2906
OMSA Trap ID
120100;150100;160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1010

Message
Caching is enabled on the arg1 with wwn = arg2 and path = arg3 .
Arguments
arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
Caching is enabled on the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2907
OMSA Trap ID
120100;150100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1012

Message
Caching is disabled for the arg1 with WWN = arg2 and path = arg3 .
Arguments
arg1 = virtual disk name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
The operation to disable caching is successful. Caching is disabled for the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2910
OMSA Trap ID
120100;150100;160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1013

Message
The cached LUN with WWN = arg1 and path = arg2 for arg3 has had a failure.
Arguments
arg1 = World Wide Name, arg2 = device pathname, arg3 = virtual disk name
Detailed Description
The cached LUN identified in the message has had a failure to successfully perform a read or write operation. The user application should now be seeing I/O failures when trying to read or write to the Fluid Cache device at the path identified in the message.
Recommended Response Action
Contact your service provider to diagnose the cause and assist in recovery process.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2911
OMSA Trap ID
140400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1014

Message
Replication of the cache device arg1 with WWN = arg2 and path = arg3 is complete.
Arguments
arg1 = physical device name, arg2 = World Wide Name, arg3 = device pathname
Detailed Description
Replication of the cache device identified in the message is complete.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2912
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1015

Message
Recovery of the cache device arg1 with wwn = arg2 and path = arg3 is complete.
Arguments
arg1 = physical disk name, arg2 = World Wide Name, arg3 = device pathnameh
Detailed Description
The recovery of the cache device identified in the message complete.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2913
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1016

Message
A valid permanent license is installed for Fluid Cache.
Detailed Description
A valid permanent license is installed for Fluid Cache.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2914
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1017

Message
A license has been installed for Fluid Cache.
Detailed Description
A license has been installed for Fluid Cache.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2920
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1018

Message
A license has been removed for Fluid Cache.
Detailed Description
A license has been removed for Fluid Cache.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2921
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1019

Message
All cache devices have been found and registered for Fluid Cache.
Detailed Description
All cache devices have been found and registered for Fluid Cache.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2924
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1020

Message
The storage device with WWN = arg1 and path = arg2 is in unknown state.
Arguments
arg1 = wwn name, arg2 = path name
Detailed Description
The storage device identified in the message is in unknown state.
Recommended Response Action
Service is required. Contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2909
OMSA Trap ID
120300;150300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1021

Message
The journal mirror entry with WWN = arg1 is not accessible.
Arguments
arg1 = World Wide Name
Detailed Description
The device identified in the message having the journal mirror entry with given WWN (World Wide Name) is not accessible. A portion of an SSD is used for journal content. To assure consistnecy, the journal content is written into two other SSDs. These copies are journal mirrors. If the journal content cannot be written to any of the journal mirrors, then this event is signaled. It is a warning because the FLDC code will then attempt to choose another SSD to be a journal mirror.
Recommended Response Action
No response action is required..
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2702
OMSA Trap ID
160300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1022

Message
The associated server of the Cache Device arg1 with WWN = arg2 is not configured.
Arguments
arg1 = physical disk name, arg2 = World Wide Name
Detailed Description
The cache device identified in the message with given WWN does not exist in the Fluid Cache configuration.
Recommended Response Action
To identify the cause of the configuration inconsistency, contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2874
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1023

Message
Fluid Cache is running on an evaluation license and the evaluation license expires in arg1 days.
Arguments
arg1 = days
Detailed Description
Fluid Cache is currently running on an evaluation license and the evaluation license expires in the number of days identified in message.
Recommended Response Action
A permanent license for Fluid Cache should be purchased for continued service.
Category
Storage (FLDC = Unknown)
Severity
Severity 3 (Informational)
OMSA Event ID
2916
OMSA Trap ID
160100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1024

Message
Caching was enabled in write-back mode, but it is currently operating in write-through mode.
Detailed Description
Caching was enabled in write-back mode but currently it is operating in write-through mode because the fluid Cache Pool has one PCIe-SSD.
Recommended Response Action
Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2930
OMSA Trap ID
120300;150300;160300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1025

Message
Caching was enabled in write-back or write-through mode, it is currently operating in pass-through mode.
Detailed Description
Caching was enabled in write-back mode or write through mode, but currently it is operating in write-through mode because fluid Cache Pool has no PCIe-SSD device.
Recommended Response Action
Add another PCIe SSD device to the Fluid Cache Pool to resolve the issue.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2931
OMSA Trap ID
120300;150300;160300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1026

Message
Caching is no longer degraded to write-through mode and is now operating in write-back mode for Fluid Cache.
Detailed Description
The caching mode has been restored back to write-back mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2932
OMSA Trap ID
120300;150300;160300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1027

Message
Caching is no longer degraded to pass-through mode and is now operating in its configured mode for Fluid Cache.
Detailed Description
The caching mode has been restored back to the configured mode due to the availability of additional PCIeSSD devices in the Fluid Cache configuration.
Recommended Response Action
No response action is required.
Category
Storage (FLDC = Unknown)
Severity
Severity 2 (Warning)
OMSA Event ID
2933
OMSA Trap ID
120300;150300,160300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1028

Message
OMSS Connection to Fluid Cache service is no longer present.
Detailed Description
The communications connnection between OMSS and the Fluid Cache service is no longer present.
Recommended Response Action
To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is running. To verify the service run the following command: "fldc --status". 2) Re-establish the connect by running the following command: :"omconfig storage fluidcache action=connect"
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2699
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1029

Message
There are not enough journal mirrors available for Fluid Cache to operate.
Detailed Description
The message indicates that there are not enough journal mirrors available for Fluid Cache to operate. Make sure that there are at least two journal mirrors that are accessible. Activate either one or more failed cache devices or use the fldc_restore utility to rebuild the node.
Recommended Response Action
Contact your service provider to diagnose the cause and assist in recovery process.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2703
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1030

Message
The cluster ID in the journal does not match the cluster ID in the configuration file for Fluid Cache.
Detailed Description
An Inconsistency was found in Fluid Cache configuration data.
Recommended Response Action
Service is required. Contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2704
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1031

Message
The journal could not be read or written to for Fluid Cache.
Detailed Description
Unable to access redundant Fluid Cache configuration information.
Recommended Response Action
Service is required. Contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2705
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1032

Message
The cache device with WWN = arg1 and path = arg2 is no longer functional.
Arguments
arg1 = wwn name, arg2 = path name
Detailed Description
The PCIeSSD cache device identified in the message is no longer functional.
Recommended Response Action
Replace the non-functional PCIe SSD.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2900
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1033

Message
The storage device WWN = arg1 and path = arg2 is either inaccessible or no longer functional.
Arguments
arg1 = wwn name, arg2 = path name
Detailed Description
The message indicates that the storage device is either inaccessible or is no longer functional.
Recommended Response Action
If the virtual disk is inaccessible, restore accessibility by bringing the virtual disk back online. After the virtual disk is accessible, run the following command to reactivate disk, "omconfig storage vdisk action=reactivate controller=id vdisk=id devicename=<string>". If the device is no longer functional, replace it.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2901
OMSA Trap ID
120400;150400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1034

Message
A valid license is not installed for Fluid Cache.
Detailed Description
A valid license is not installed for Fluid Cache.
Recommended Response Action
Install a valid Fluid Cache license. For more information, contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2915
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1035

Message
Configuration changes are not allowed, because Fluid cache is running on an expired evaluation licesnse (Expired days: arg1 ).
Arguments
arg1 = number of days
Detailed Description
Configuration changes are not allowed because Fluid Cache is running on an expired evaluation license. The message also indicates the number of days that Fluid Cache has been running with an expired license (maximum 30 days after expiration are allowed).
Recommended Response Action
Install a valid Fluid Cache license. For more information, contact your service provider.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2917
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1036

Message
Caching functionality is disabled because Fluid cache is running on an expired evaluation license (Expired days: arg1 ).
Arguments
arg1 = number of days
Detailed Description
Caching functionality is disabled because Fluid cache is running on an expired evaluation license. The message also indicates the number of days that Fluid Cache has been running with an expired license (maximum 30 days after expiration are allowed).
Recommended Response Action
Install a permanent Fluid Cache license.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2918
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1037

Message
Configuration changes are disabled, because Fluid cache is running on an expired or invalid license.
Detailed Description
Configuration changes are disabled, because Fluid cache is running on an expired or invalid license.
Recommended Response Action
Install a permanent Fluid Cache license.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2919
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1038

Message
There is not enough memory capacity to run necessary services for Fluid Cache.
Detailed Description
There is not enough memory capacity to run necessary services for Fluid Cache.
Recommended Response Action
The minimum memory required to run Fluid Cache for DAS is 16 GB. For optimum operation, recommendation is to install 32 GB of RAM.
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2922
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

FLDC1039

Message
One or more cache devices are missing, resulting in Fluid Cache to be unresponsive.
Detailed Description
One or more cache devices are missing and the cache is unresponsive.
Recommended Response Action
Insert the missing cache device. If the cache device was unplugged, reactivate it. Reactivate a cache device by running the following command: "omconfig storage pciessd action=reactivate subsystem=id pciedevice=<PDISKID>"
Category
Storage (FLDC = Unknown)
Severity
Severity 1 (Critical)
OMSA Event ID
2923
OMSA Trap ID
160400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\