PCI Event Messages

PCI1300

Message
A front panel diagnostic interrupt was detected.
Detailed Description
The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced.
Recommended Response Action
Reset the system to continue operation.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PCI1302

Message
A bus time-out was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded. The device has failed to respond to a transaction (master/target abort or completion timeout).
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1304

Message
An I/O channel check error was detected.
Detailed Description
None
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
I/O channel check error detected. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1306

Message
A software error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
None
Recommended Response Action
Reboot the system and update the component drivers.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1308

Message
A PCI parity error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
PCI parity error on bus <bus> device <device> function <func>. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1310

Message
A PCI system error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
PCI system error on bus <bus> device <device> function <func>. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1312

Message
An EISA fail-safe time-out was detected.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PCI1314

Message
A bus correctable error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded.
Recommended Response Action
Cycle input power, update component drivers, if device is removable re-install the device at the next scheduled service time.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1316

Message
A bus uncorrectable error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1318

Message
A fatal error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Fatal error on bus <bus> device <device> function <func>. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1319

Message
A high-severity issue is detected in the SSD bay arg1 , Slot arg2 .
Arguments
arg1 = bay id, arg2 = slot id
Detailed Description
A high-severity issue was detected in the SSD bay identified in the message.
Recommended Response Action
Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PCI1320

Message
A bus fatal error was detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Bus fatal error on bus <bus> device <device> function <func>. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1321

Message
A high-severity issue is detected in a component of the bus arg1 , device 0, function arg2 .
Arguments
arg1 = bus ID, arg2 = function ID
Detailed Description
A high-severity issue is detected in the component identified in the message.
Recommended Response Action
Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PCI1322

Message
Bus performance degraded for a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded. The bus is not operating at maximum speed or width.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1342

Message
A bus time-out was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded. The device has failed to respond to a transaction (master/target abort or completion timeout).
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1344

Message
An I/O channel check error was detected.
Detailed Description
None
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
An I/O channel check error detected. Power cycle system.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1346

Message
A software error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Reboot the system and update the component drivers.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1348

Message
A PCI parity error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
PCI parity error on slot <number>. Reseat PCI card
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1350

Message
A PCI system error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
PCI system error on slot <number>. Reseat PCI card
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1354

Message
A bus correctable error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1356

Message
A bus uncorrectable error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1358

Message
A fatal error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Fatal error on slot <number>. Reseat PCI card
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1360

Message
A bus fatal error was detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Bus fatal error on slot <number>. Reseat PCI card
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI1362

Message
Bus performance degraded for a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded. The bus is not operating at maximum speed or width.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI2000

Message
A fatal IO error detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Fatal IO error on bus <bus> device <device> function <func>. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI2001

Message
The component at bus arg1 device arg2 function arg3 recovered from a fatal IO error.
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI2002

Message
A fatal IO error detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded, or system may fail to operate.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
LCD Message
Fatal IO error on slot <number>. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI2003

Message
The component at slot arg1 recovered from a fatal IO error.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3000

Message
Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress.
Detailed Description
Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support FlexAddress.
Recommended Response Action
Update BIOS, BMC/iDRAC, and LOM firmware. If problem persists please contact customer support.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3001

Message
Device option ROM on embedded NIC was successfully updated.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3002

Message
Failed to program virtual MAC address on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress.
Recommended Response Action
Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If problem persists please contact customer support.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3003

Message
Virtual MAC address for component at bus arg1 device arg2 function arg3 was successfully programed.
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3004

Message
Device option ROM on mezzanine card arg1 failed to support Link Tuning or FlexAddress.
Arguments
arg1 = number
Detailed Description
Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
Recommended Response Action
Update BIOS, BMC/iDRAC, and mezzanine card firmware. If problem persists please contact customer support.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3005

Message
Device option ROM on mezzanine card arg1 was successfully updated.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3006

Message
Failed to get Link Tuning or FlexAddress data from iDRAC.
Detailed Description
Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.
Recommended Response Action
Update BIOS, and BMC/iDRAC firmware. If problem persists please contact customer support.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3007

Message
Link Tuning or FlexAddress data successfully obtained.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3008

Message
A non-fatal PCIe error detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device at the next service window.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3009

Message
PCIe is operating normally on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3010

Message
A non-fatal IO error detected on a component at bus arg1 device arg2 function arg3 .
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
System performance may be degraded.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device at the next service window.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3011

Message
The component at bus arg1 device arg2 function arg3 recovered from a non-fatal IO error.
Arguments
arg1 = bus, arg2 = device, arg3 = func
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3012

Message
The QuickPath Interconnect (QPI) width degraded.
Detailed Description
System performance may be degraded. The bus is not operating at maximum speed or width.
Recommended Response Action
Reset the system, if the problem persists reinstall processors.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3013

Message
The QuickPath Interconnect (QPI) width regained.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3014

Message
A non-fatal PCIe error detected on a component at slot arg1 .
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3015

Message
The component at slot arg1 recovered from a non-fatal PCIe error.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3016

Message
Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress.
Detailed Description
Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
Recommended Response Action
Update BIOS, BMC/iDRAC, and mezzanine card firmware. If problem persists please contact customer support.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3017

Message
Device option ROM on mezzanine card was successfully updated.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PCI3018

Message
New PCI card(s) have been detected in the system. Fan speeds may have changed to add additional cooling to the cards.
Detailed Description
New PCI card(s) have been detected in the system that may require additional airflow. Fan speeds may have changed to add additional cooling to the cards.
Recommended Response Action
Changing default fan response to PCIe cards should be done with appropriate understanding of the PCIe cooling needs of the cards present in the system. If the automatic cooling response is insufficient, additional cooling can be added by one of the following methods. 1) From iDRAC Web GUI, click Hardware -> Fans -> Setup, then from the fan speed offset drop-down list appropriately select the cooling level needed or set the minimum fan speed to a custom value. 2) From F2 System Setup, select iDRAC Settings -> Thermal, and set a higher fan speed from the fan speed offset or minimum fan speed. 3) For RACADM commands run "racadm help system.thermalsettings". If a lower fan speed is required, contact your service provider for the appropriate IPMI commands to reduce the default fan speed response for new PCIe cards.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔*   ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC              

PCI3019

Message
A low-severity issue is detected in the SSD bay arg1 , Slot arg2 .
Arguments
arg1 = bay id, arg2 = slot id
Detailed Description
A low-severity issue was detected in the SSD bay identified in the message.
Recommended Response Action
Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message..
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PCI3020

Message
A low-severity issue is detected in a component of the bus arg1 , device 0, function arg2 .
Arguments
arg1 = bus ID, arg2 = function ID
Detailed Description
A low-severity issue is detected in the component identified in the message.
Recommended Response Action
Remove and reinsert the component identified in the message, and then monitor the log for a re-occurrance of the issue. If the issue persists, and occurs during server startup, update the component firmware. If the issue persists and occurs during OS runtime, restart the server and update the OS drivers for the component identified in the message.
Category
System Health (PCI = PCI Device)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PCI5001

Message
A PCIe card carrier containing a PCIe card is inserted in PCIe slot arg1 .
Arguments
arg1 = slot number
Detailed Description
A PCIe card carrier containing a PCIe card is present in the slot identified in the message. This PCIe card will be enabled when the associated server is turned on or power cycled.
Recommended Response Action
Turn on or power cycle the associated server to enable the PCIe card.
Category
Configuration (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
10611
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5002

Message
A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot arg1 .
Arguments
arg1 = slot number
Detailed Description
A PCIe card carrier that does not contain a PCIe card is inserted in the PCIe slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
10611
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔*   ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5003

Message
A PCIe card carrier is removed from the PCIe slot arg1 .
Arguments
arg1 = slot number
Detailed Description
A PCIe card carrier is removed from the PCIe slot identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
10611
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5004

Message
A power fault issue is detected in the PCIe adapter that was turned on in PCIe slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message.
Recommended Response Action
Make sure that: 1) The PCIe adapter used is supported by the Chassis Management Controller (CMC). For a list of supported adapters, contact your service provider. 2) The adapter is not damaged. 3) The power requirement of adapter is not more than the power allocated to the slot. 4) The adapter is properly inserted in the slot.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔*   ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5005

Message
An auxiliary power fault issue is detected in the PCIe adapter that was turned on in PCIe slot arg1 .
Arguments
arg1 = slot number
Detailed Description
Chassis Management Controller (CMC) detected an issue in the PCIe adapter that was turned on in the slot identified in the message.
Recommended Response Action
Make sure that: 1) The PCIe adapter used is supported by the Chassis Management Controller (CMC). For a list of supported adapters, contact your service provider. 2) The adapter is not damaged. 3) The adapter is properly inserted in the slot.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5006

Message
The power-related issue of the PCIe adapter in slot arg1 is resolved.
Arguments
arg1 = slot number
Detailed Description
The power related issue of the PCIe device in the slot identified in the message is resolved.
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5007

Message
The auxiliary power-related issue of the PCIe adapter in slot arg1 is resolved.
Arguments
arg1 = slot number
Detailed Description
The 3.3 Volt Regulator power related issue of PCIe carrier present in the slot identified in the message is resolved.
Recommended Response Action
No response action is required.
Category
System Health (PCI = PCI Device)
Severity
Severity 3 (Informational)
Trap/EventID
2419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5008

Message
The Chassis Management Controller (CMC) is unable to communicate with the PCIe switch board.
Detailed Description
The Chassis Management Controller (CMC) could not successfully connect to the PCIe switch board.
Recommended Response Action
Do the following: 1) Perform an AC Power Cycle operation on the Chassis by disconnecting the chassis from AC power, waiting for 30 seconds, and then reconnecting AC power. 2) Power on at least one server. Using the Chassis Management Controller (CMC) web interface, select Server Overview->Power->Control and then click the Operation field and select the Power On Server operation. If the issue persists, contact your service provider.
Category
System Health (PCI = PCI Device)
Severity
Severity 1 (Critical)
Trap/EventID
2417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PCI5009

Message
The PCIe adapter in the PCIe slot arg1 was removed from the slot while the server arg2 was turned-on.
Arguments
arg1 = PCIe slot number, arg2 = server slot number
Detailed Description
Chassis Management Controller (CMC) detected that a PCIe adapter was removed from a server which was turned-on. This may cause the server operating system to stop responding or to function in an improper manner.
Recommended Response Action
Perform a Power Cycle operation on the associated server. Restarting the operating system will not resolve this issue. Only remove PCIe adapters when the associated server is turned-off.
Category
Audit (PCI = PCI Device)
Severity
Severity 2 (Warning)
Trap/EventID
8562
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\