Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

BAT Event Messages

BAT0000

Message
The system board battery is low.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0001

Message
The system board battery is operating normally.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
OMSA Event ID
5702
OMSA Trap ID
5702
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

BAT0002

Message
The system board battery has failed.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
System board battery has failed. Check battery
OMSA Event ID
57,045,705
OMSA Trap ID
5704
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0003

Message
The system board battery is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

BAT0004

Message
The system board battery is absent.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
System board battery is absent. Check battery
OMSA Event ID
5700
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0005

Message
The storage battery is low.
Detailed Description
The system has to remain powered on to charge the battery.
Recommended Response Action
Allow the PERC RAID controller battery to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0006

Message
The storage battery is operating normally.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0007

Message
The storage battery has failed.
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Storage battery has failed. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0008

Message
The storage battery is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0009

Message
The storage battery is absent.
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Storage battery is absent. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0010

Message
The storage battery for disk drive bay arg1 is low.
Arguments
arg1 = bay
Detailed Description
The system has to remain powered on to charge the battery.
Recommended Response Action
Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0011

Message
The storage battery for disk drive bay arg1 is operating normally.
Arguments
arg1 = bay
Detailed Description
None
Recommended Response Action
Verify the battery installation, check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0012

Message
The storage battery for disk drive bay arg1 has failed.
Arguments
arg1 = bay
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> has failed. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0013

Message
The storage battery for disk drive bay arg1 is present.
Arguments
arg1 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0014

Message
The storage battery for disk drive bay arg1 is absent.
Arguments
arg1 = bay
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> is absent. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0015

Message
The arg1 battery is low.
Arguments
arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0016

Message
The arg1 battery is operating normally.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0017

Message
The arg1 battery has failed.
Arguments
arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
The <name> battery has failed. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0018

Message
The arg1 battery is present.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0019

Message
The arg1 battery is absent.
Arguments
arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
The <name> battery is absent. Check battery.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0030

Message
The system board battery is reading low.
Detailed Description
The system battery level is low, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5703
OMSA Trap ID
5703
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

BAT0031

Message
The system board battery status is unknown.
Detailed Description
The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5701
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

BAT1000

Message
Battery on arg1 is missing.
Arguments
arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message.
Recommended Response Action
Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling. In addition check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may cause this message.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2264
OMSA Trap ID
75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1001

Message
Battery on arg1 was replaced.
Arguments
arg1 = controller name
Detailed Description
A controllers battery was replaced.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2175
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1002

Message
The battery on arg1 learn cycle has started.
Arguments
arg1 = controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2176
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1003

Message
The battery on arg1 learn cycle has completed.
Arguments
arg1 = controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2177
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1004

Message
The battery on arg1 learn cycle has timed out.
Arguments
arg1 = controller name
Detailed Description
The controller battery must be fully charged before the learn cycle can begin. The battery may be unable to maintain a full charge causing the learn cycle to timeout. In addition, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Recommended Response Action
Replace the battery pack. The battery is unable to maintain a full charge.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2178
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1005

Message
The battery on arg1 learn cycle has been postponed.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2179
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1006

Message
The battery on arg1 learn cycle will start in arg2 days.
Arguments
arg1 = Controller name, arg2 = arg
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2180
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1007

Message
The battery on arg1 learn cycle will start in arg2 hours.
Arguments
arg1 = Controller name, arg2 = arg
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2181
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1008

Message
Write policy on arg1 was changed to Write Through.
Arguments
arg1 = controller name
Detailed Description
The controller battery cannot maintain cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery cannot maintain cached data for 24 hours.
Recommended Response Action
Verify the battery health is good. See the storage hardware documentation to verify battery health. Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2188
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1009

Message
Write policy on arg1 was changed to Write Back.
Arguments
arg1 = controller name
Detailed Description
The controller battery health has returned to normal.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2189
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

BAT1010

Message
Battery on arg1 requires reconditioning. Initiate a learn cycle.
Arguments
arg1 = Controller name
Detailed Description
Battery is in warn only mode and requires reconditioning.
Recommended Response Action
Start a learn cycle on the battery.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2210
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1011

Message
Battery on arg1 is in warn only mode and requires reconditioning.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2104
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1012

Message
The arg1 battery temperature is above normal.
Arguments
arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1013

Message
Recharge count has exceeded the maximum limit for battery on arg1 .
Arguments
arg1 = Controller name
Detailed Description
The battery cannot be recharged further.
Recommended Response Action
Replace the battery pack.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2213
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1014

Message
arg1 battery charge in-progress.
Arguments
arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2214
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

BAT1015

Message
arg1 battery charge process is interrupted.
Arguments
arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2215
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1016

Message
The arg1 battery learn mode has changed to Auto.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2216
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1017

Message
The arg1 battery learn mode has changed to Warn.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2217
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1018

Message
Battery on arg1 is degraded.
Arguments
arg1 = Controller name
Detailed Description
The temperature of the battery is high. This may be due to the battery being charged.
Recommended Response Action
If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2246
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1019

Message
Battery on arg1 is charging.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2247
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1020

Message
The arg1 battery is executing a learn cycle.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2248
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1021

Message
The charge level for the battery on arg1 is below the normal threshold.
Arguments
arg1 = controller name
Detailed Description
The controller battery cannot maintain sufficient charge level to function properly or the battery is discharging.
Recommended Response Action
Check for other events related to the state of the battery. These may help determine the cause of this event.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2278
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1022

Message
arg1 battery recondition is completed.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2105
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1023

Message
The charge level for the battery on arg1 is within normal limits.
Arguments
arg1 = controller name
Detailed Description
The battery health has returned to normal.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2279
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1024

Message
Errors detected with battery on arg1 .
Arguments
arg1 = controller name
Detailed Description
The battery or the battery charger is not functioning properly. The battery may have an inadequate charge.
Recommended Response Action
Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2318
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1025

Message
arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
arg1 = controller name
Detailed Description
The controller was unable to recover data from the cache. This may indicate data loss has occurred.
Recommended Response Action
Verify that the battery is charged and in good health. See the hardware documentation for more information. When the battery charge is unacceptably low, the battery cannot maintain cached data. Data loss may also have occurred, restoring data from backups may be needed. Verify whether the battery has met its recharge limit. The battery may need to be recharged. Contact technical support if the issue persists.
Category
Storage (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
4273
OMSA Event ID
2337
OMSA Trap ID
115400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1026

Message
The arg1 has recovered cached data from the Battery Backup Unit (BBU).
Arguments
arg1 = controller name
Detailed Description
The controller has retrieved cached data.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2338
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1027

Message
The battery on arg1 completed a charge cycle.
Arguments
arg1 = controller name
Detailed Description
The battery successfully completed a charge cycle.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2358
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1028

Message
The battery voltage on arg1 is low.
Arguments
arg1 = controller name
Detailed Description
The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache.
Recommended Response Action
The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2145
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1029

Message
The battery on arg1 can no longer recharge.
Arguments
arg1 = controller name
Detailed Description
The controller battery cannot recharge. The battery may have already recharged the maximum number of times or the battery charger may not be working.
Recommended Response Action
Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
4273
OMSA Event ID
2169
OMSA Trap ID
115400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1030

Message
The arg1 battery charge level is normal.
Arguments
arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2170
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*        

BAT1031

Message
The battery temperature on arg1 is above normal.
Arguments
arg1 = controller name
Detailed Description
The room temperature may be too hot. In addition, the system fan may be degraded or failed.
Recommended Response Action
Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2171
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1032

Message
The battery temperature on arg1 is normal.
Arguments
arg1 = controller name
Detailed Description
The battery temperature is within the normal operating range.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2172
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1033

Message
The battery on arg1 was removed.
Arguments
arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
Recommended Response Action
Make sure that the battery is present and properly connected. If the battery is present, wait for a few minutes and re-check if the battery is detected. If the contact point between the battery and the controller is degraded, you must replace the battery, the controller, or both. Refer to the storage hardware documentation for information on how to safely access, or remove. Contact technical support if the issue persists.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2174
OMSA Trap ID
115300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1034

Message
The battery properties for arg1 have changed.
Arguments
arg1 = controller name
Detailed Description
One or more battery properties were modified.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

BAT1035

Message
The battery temperature on arg1 is above the normal operating temperature.
Arguments
arg1 = controller name
Detailed Description
The battery temperature is above normal operating temperature.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
OMSA Event ID
2212;2415
OMSA Trap ID
115100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

BAT1036

Message
The battery on arg1 is discharging.
Arguments
arg1 = controller name
Detailed Description
The battery on the controller identified in the message is being discharged.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\