Dell OpenManage Deployment Toolkit Version 5.4 Command Line Interface Reference Guide

PDF

pefcfgparams

Table 1. pefcfgparamsThe following table describes the option, sub-option, valid arguments and descriptions for the pefcfgparams.
Option Sub-option Valid Arguments Description
pefcfgparams or pcp Configures and displays PEF configuration parameters. This option can be replicated.
--filter fanfail, voltfail, discretevoltfail, tempwarn, tempfail, intrusion, redundegraded,redunlost, procwarn, procfail, powerwarn, powerfail, hardwarelogfail, autorecovery, batterywarn, batteryfail, powerabsent, procabsent, systempowerwarn, systempowerfail

Specifies a PEF value. This sub-option can be replicated.

For a complete list of all possible PEF messages along a description of each event, see BMC Platform Events Filter Alert Messages

--filteraction powercycle, reset, powerdown, power reduction, none Sets the event filter action for the filter specified using the filter sub-option. This sub-option depends on the filter sub-option. This sub-option can be replicated.
--hostname <string>

Sets the host name (maximum of 62 printable ASCII characters) for the BMC. This sub-option can be replicated.

The hostname string must comprise only the followig characters: hyphen (-) , underscore (_) , and period (.) .

--filteralert enable, disable Enables or disables alerts for the filter specified using the filter sub-option. This sub-option is dependent on the filter sub-option. This sub-option can be replicated.
--alertpolnum 1, 2, 3, 4 Specifies the alert policy entry number. This sub-option can be replicated.
--alertpolstatus enable, disable

Enables or disables the alert policy specified using the alertpolnum sub-option. This sub-option can be replicated. This sub-option is dependent on the alertpolnum sub-option.

Example: (to set the PEF configuration parameters):

Example 1 (To configure the PEF so that the system is powered down in response to a fan failure event):

A:>syscfg pefcfgparams --filter= fanfail--filteraction=powerdown  
pefcfgparams filter=fanfail filteraction=powerdown

Example 2 (To configure the PEF so that a PEF alert is not sent to the destination IP address in response to a chassis intrusion event):

A:>syscfg pefcfgparams --filter= intrusion--filteralert=disable
pefcfgparams filter= intrusion filteralert=disable