Specifications for the components of the XC450 are provided.
The following XC450 specifications are provided:
Chassis dimensions
System weight
Processor specifications
PSU specifications
Supported operating systems
Cooling fan specifications
System battery specifications
Expansion card riser specifications
Memory specifications
Storage controller specifications
Disk drives
USB port specifications
NIC port specifications
Serial connector specifications
VGA port specifications
Video specifications
Environment specifications
Particulate and gaseous contamination specifications
Thermal restrictions
Chassis dimensions
The following table provides the chassis dimensions for the XC Core XC450:
Table 1. Chassis dimensions for the XC Core XC450Chassis dimensions for the XC Core XC450.
Drives
Xa
Xb
Y
Za
Zb
Zc
4 x 3.5 in
482 mm
(18.976 in)
434 mm
(17.08 in)
42.8 mm
(1.685 in)
22 mm (0.866 in) without bezel
35.84 mm (1.41 in) with bezel
677.8 mm (26.685 in)
(Ear to PSU surface)
691.07mm (27.207 in)
(Ear to butterfly L bracket housing)
712.95 mm (28.069 in)
(Ear to PSU handle without velcro strap)
System weight
The following table provides the XC Core XC450 weight:
Table 2. XC Core XC450 weightXC Core XC450 weight
System configuration
Maximum weight
(with all drives/SSDs/bezel)
4 x 3.5-inch system
18.62 kg (41.05 pound)
Processor specifications
The following table provides the processor specifications for the XC Core XC450:
Table 3. Processor specifications for the XC Core XC450Processor specifications for the XC Core XC450
Supported processor
Number of processors supported
3rd Generation Intel Xeon Scalable processors with up to 24 cores
Up to two
Table 4. PSU specificationsPSU specifications
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
AC
DC
Current
High line 200–240 V
Low line 100–120 V
1100 W DC
NA
4265 BTU/hr
NA
-48–(-60) V
NA
NA
1100 W
27 A
800 W
Mixed Mode
Platinum
3000 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
800 W
800 W
NA
9.2 A-4.7 A
NA
3000 BTU/hr
NA
240 V DC,
autoranging
NA
NA
800 W
3.8 A
600 W
Mixed Mode
Platinum
2250 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
600 W
600 W
NA
7.1 A-3.6 A
NA
2250 BTU/hr
NA
240 V DC,
autoranging
NA
NA
600 W
2.9 A
This XC Core XC450 is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
Heat dissipation is calculated using the PSU wattage rating.
When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Enterprise Infrastructure Planning Tool available at
Dell Enterprise Infrastructure Planning Tool.
Supported operating systems
The XC Core XC450 supports the following operating systems:
New cooling fans comes with the High Performance Silver Grade label. The older cooling fans have the High Performance label.
High performance (Silver grade) fan
System battery specifications
The XC Core XC450 supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specifications
The XC Core XC450 supports up to two PCI express (PCIe) Gen 4 expansion cards.
The following table provides details on the supported expansion card risers:
For information on the expansion card installation guidelines, see the system-specific installation and service manual available at
Dell Support (Browse all Products > Infrastructure, then go to the system.)
The XC Core XC450 supports the following memory specifications for optimized operation:
The XC Core XC450 supports the following controller cards:
HBA355i
Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs
Disk drives
The XC Core XC450 supports 4 x 3.5-in hot-swappable SAS, SATA (HDD/SSD) drives.
USB ports specifications
The XC Core XC450 supports the USB ports listed in the following table:
Table 9. Supported USB portsSupported USB ports
Front
Front
Rear
Rear
Internal (Optional)
Internal (Optional)
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 3.0-compliant port
One
USB 2.0-compliant port
One
Internal USB 3.0-compliant port
One
Micro-USB 2.0-compliant port for iDRAC Direct
One
USB 3.0-compliant port
One
The micro USB 2.0-compliant port can only be used as an iDRAC Direct or a management port.
NIC port specifications
The XC Core XC450 supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) and integrated on the optional Open Compute Project (OCP) cards. The following table provides details:
Table 10. NIC port specificationsNIC port specifications
Feature
Specifications
LOM card
1 GbE x 2
OCP card (OCP 3.0)
1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4
Serial connector specifications
The XC Core XC450 supports one optional card type serial connector on rear of the system. The connector is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .
The process to install the optional serial connector card is similar to an expansion card filler bracket.
VGA ports specifications
The XC Core XC450 supports two DB-15 VGA ports, one each on the front and rear panels of the system.
Video specifications
The XC Core XC450 supports an integrated Matrox G200 graphics controller with 16 MB of video frame buffer. Details are provided in the following table:
Table 11. Video specificationsVideo specifications
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Environmental specifications
NOTE:For additional information about environmental certifications, see the product environmental datasheet that is located with the
Manuals & Documents on
Dell Support.
The following table provides information for operational climatic range, category A2:
Temperature ranges for altitudes <= 900 m (<= 2,953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
The following table provides information for shared requirements across all categories:
Table 13. Shared requirementsShared requirements.
Temperature
Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits
-40 to 65°C (-40 to 149°F)
Non-operational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude
12,000 meters (39,370 feet)
Maximum operational altitude
3,048 meters (10,000 feet)
The following table specifies the maximum allowed vibration:
Table 14. Maximum allowed vibration Maximum allowed vibration.
Maximum vibration
Specifications
Operating
0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage
1.88 Grms at 10 Hz to 500 Hz for 15 minutes
(all six sides tested)
The following table specifies the shock pulse maxima:
Table 15. Shock pulse maximaShock pulse maxima.
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Particulate and gaseous contamination specifications
This section defines the limitations that prevent damage to the IT equipment from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
The following table contains particulate contamination specifications:
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
This condition applies to data center and non-data center environments.
Corrosive dust
Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
This condition applies to data center and non-data center environments.