Dell EMC Metro node 7.0.1 Administrator Guide

Limitations with storage-volume expansion

The following limitations apply to the storage volume expansion method:

  • For virtual volumes built on RAID 1 or distributed RAID 1 devices, a maximum of 1000 initialization processes can run concurrently per cluster. If this limit is reached on a cluster, then no new expansions can be started on virtual volumes with these geometries until some of the previously started initialization processes finish on that cluster.

Virtual volumes that do not contain RAID 1 or distributed RAID 1 devices are not affected by this limitation.