WARNING: The
Edge Gateway must be installed by knowledgeable, skilled persons familiar
with local and/or international electrical codes and regulations.
WARNING: The Edge Gateway is not designed for use in wet environments. If
the Edge Gateway is to be installed in a wet environment, depending
on the location and environment, it must be installed in a panel box
or enclosure with an Ingress Protection (IP) rating of IP54, IP65,
or higher.
WARNING: To reduce the risk of electric shock, power to the
DC+ and DC- terminals must be provided by a power supply or transformer/rectifier
circuit that is designed with double-insulation. The power supply
or power circuit source must comply with local codes and regulations;
for example, in the USA, NEC Class 2 (SELV/limited energy circuit,
or LPS circuitry). If powered by a battery, double-insulation is not
required.
WARNING: When installing the Edge Gateway, the responsible
party or integrator shall use the 12-57 VDC or Power over Ethernet
(PoE) power source 37-57 VDC, with a minimum of 13 W power already
present as part of the client’s installation.
WARNING: Ensure
that the power source providing power to the Edge Gateway is reliably
grounded and filtered such that the peak-to-peak ripple component
is less than 10 percent of the input DC voltage.
WARNING: When installing the Edge Gateway 3001 and 3002, use
a cable appropriate for the load currents: 3-core cable rated 5 A
at 90°C (194°F) minimum, which conform to either IEC 60227 or IEC
60245. The system accepts cables from 0.8 mm to 2 mm. The maximum
operating temperature of the Edge Gateway is 70⁰C (158°F). Do not
exceed this maximum temperature while operating the Edge Gateway inside
an enclosure. Internal heating of the Edge Gateway electronics, other
electronics, and the lack of ventilation inside an enclosure can cause
the operating temperature of the Edge Gateway to be greater than the
outside ambient temperature. Continuous operation of the Edge Gateway
at temperatures greater than 70⁰C (158°F) may result in an increased
failure rate and a reduction of the product life. Ensure that the
maximum operating temperature of the Edge Gateway when placed inside
an enclosure is 70⁰C (158°F) or less.
WARNING: Always
ensure that the available power source matches the required input
power of the Edge Gateway. Check the input power markings next to
power connector(s) before making connections. The 12-57 VDC (1.08-0.23
A) or the PoE power source must be compliant with local Electrical
Codes and Regulations.
WARNING: To ensure
the protection provided by the Edge Gateway is not impaired, do not
use or install the system in any manner other than what is specified
in this manual.
WARNING: If a
battery is included as part of the system or network, the battery
must be installed within an appropriate enclosure in accordance with
local fire and electrical codes and laws.
WARNING: The
system is for installation in a suitable industrial enclosure (provides
electrical, mechanical, and fire hazard protection).
WARNING: The
core module only can be wall-mounted (without the need for an additional
enclosure).
Professional installation
instructions
Installation personnel
This product is designed for specific applications
and needs to be installed by qualified personnel with RF and regulatory-related
knowledge. The general user shall not attempt to install or change
the setting.
Installation location
The product shall be installed at a location where the
radiating antenna is kept 20 cm from nearby persons in its normal
operation condition in order to meet regulatory RF exposure requirements.
External antenna
Use only
approved antenna(s). Non-approved antenna(s) may produce spurious
or excessive RF transmitting power which may lead to a violation of
FCC/IC limits.
Installation procedure
Refer to user’s manual for installation instructions.
WARNING: Carefully select the installation position and make
sure that the final output power does not exceed the limits described
in the product’s documentation. The violation of these rules could
lead to serious federal penalties.
Instructions d'installation
professionnelles
Le personnel d'installation
Ce produit est conçu pour des applications spécifiques
et doit être installé par un personnel qualifié avec RF et connaissances
connexes réglementaire. L'utilisateur ne doit pas tenter générale
d'installer ou de modifier le réglage.
Lieu d'installation
Le produit doit être installé à un endroit où
l'antenne de rayonnement est maintenue à 20 cm de personnes à proximité
dans son état de fonctionnement normal, afin de répondre aux exigences
réglementaires d'exposition aux radiofréquences.
Antenne externe
Utilisez uniquement l'antenne(s)
qui ont été approuvés par le demandeur. Antenne (s) peuvent produire
de l'énergie RF parasite indésirable ou excessive transmission qui
peut conduire à une violation des normes de la FCC / IC est interdite
et non-approuvé.
Procédure d'installation
ATTENTION: S'il vous plaît choisir avec soin
la position d'installation et assurez-vous que la puissance de sortie
final ne dépasse pas les limites fixées dans les règles pertinentes.
La violation de ces règles pourrait conduire à des sanctions fédérales
graves.
Federal Communication
Commission interference statement
This device
complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one
of the following measures:
Reorient
or relocate the receiving antenna.
Increase
the separation between the equipment and receiver.
Connect the
equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the
dealer or an experienced radio/TV technician for help.
FCC caution:
Any changes
or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This transmitter
must not be co-located or operating in conjunction with any other
antenna or transmitter.
Radiation exposure statement:
This equipment complies with FCC radiation exposure limits for an
uncontrolled environment. This equipment should be installed and operated
with a minimum distance of 20 cm between the active transceiver and
your body.
NOTE: The country code selection
is for a non-US model only and is not available to all US model. Per
FCC regulation, all WiFi products marketed in the US must be fixed
to US operation channels only.
Industry Canada statement
This device complies with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions:
this device
may not cause interference, and
this device
must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
l'appareil
ne doit pas produire de brouillage, et
l'utilisateur
de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, the radio
transmitter(s) may only operate using an antenna(s) of a type and
maximum (or lesser) gain approved for the transmitter(s). To reduce
potential radio interference to other users, the antenna type(s) and
gain(s) should be chosen so that the Equivalent Isotropic Radiated
Power (E.I.R.P.) is not more than what was approved for the transmitter(s).
This Class A digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe A
est conforme à la norme NMB-003 du Canada.
This
device complies with RSS-210 of Industry Canada. Operation is subject
to the condition that this device does not cause harmful interference.
Cet appareil est conforme à la norme RSS-210 d'Industrie
Canada. L'opération est soumise à la condition que cet appareil ne
provoque aucune interférence nuisible.
This device
and its antenna(s) must not be co-located or operating in conjunction
with any other antenna or transmitter, except tested built-in radios.
Cet appareil et son antenne ne doivent pas être situés
ou fonctionner en conjonction avec une autre antenne ou un autre émetteur,
exception faites des radios intégrées qui ont été testées.
The County Code Selection feature is disabled for products
marketed in the US/Canada.
La fonction de sélection
de l'indicatif du pays est désactivée pour les produits commercialisés
aux États-Unis et au Canada.
Radiation Exposure
Statement: This equipment complies with IC radiation exposure
limits set forth for an uncontrolled environment. This equipment should
be installed and operated with minimum distance of 20 cm between the
active transceiver and your body.
Déclaration
d'exposition aux radiations: Cet équipement est conforme aux limites
d'exposition aux rayonnements IC établies pour un environnement non
contrôlé. Cet équipement doit être installé et utilisé avec un minimum
de 20 cm de distance entre la source de rayonnement et votre corps.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\