Dell EMC DSS8440 Installation and Service Manual

PSU specifications

The system supports up to four redundant AC power supply units (PSUs).

Table 1. PSU specificationsThe following table shows the specifications for 2400 W power supplies:
Functions2400W Power supply
Input
Input voltage range AC input : 200Vac~240Vac @ High line : 2400W
Frequency 50/60 Hz
Efficiency VIN=230Vac
  • 89% @ 10% load
  • 93% @ 20%load
  • 94% @ 50% load
  • 100% load @ 91.5% load
Power Factor PF at 230Vac/50,60 Hz
  • > 0.88 @ 10% load
  • > 0.94 @ 20% load
  • > 0.98 @ 50% load
  • > 0.99 @ 100% load
iTHD 230Vac/60 Hz
  • 25% @ 0% load
  • 25% @10% load
  • 10% @ 20% load
  • 5% @50% load
  • 4% @100% load
Hold-up Time 13.5ms @ 100% load
Conducted EMI Class A
Radiated EMI Class A
Output
Main DC Output
Voltage Regulation 12.2V +/-5%
Output current 196.72A @ high line
Standby Output
Voltage Regulation 12V +/-5%
Output current 3.5A