Connection to a Fibre Channel fabric, iSCSI network, or a direct connection to servers with SAS HBAs
Ethernet connectors
MGMT – 1 Gbps or 10 Gbps embedded Ethernet/iSCSI port that is typically used for system management
REPL – 1 Gbps or 10 Gbps embedded iSCSI port that is typically used for replication to another
Storage Center
SAS connectors
6 Gbps SAS connectors for SAS port redundancy and additional
expansion enclosures
NOTE SAS connectors are SFF-8086/SFF-8088 compliant
USB Connector
One USB 3.0 connector
NOTE For engineering use only
Serial connector
Used for initial configuration and support only functions
Table 6. LEDsLED specifications.
LED Indicators
Front panel
One two-color LED indicator for system status.
One single-color LED indicator for power status.
Two-digit, seven-segment display indicating the
storage system ID number
ID button with a single-color LED indicating startup and pressed states
Hard drive carrier
One single-color activity LED
One single-color LED status indicator per drive
Storage controller module
Two single-color LEDs per Ethernet port indicating activity and link speed
Four dual-color LEDs per SAS connector indicating port activity and status
One single-color LED indicating status
One single-color LED indicating fault
One single-color LED for identification
Eight single-color LED for diagnostics
Power supply/cooling fan
Four LED status indicators for Power Supply Status, AC Fail status, DC Fail status, and Fan Fail status
Table 7. Power SuppliesPower supply specifications.
Power Supplies
AC power supply (per power supply)
Wattage
580 W (maximum wattage: 584 W)
Voltage
100–240 VAC (7.6 A–3.0 A)
Heat dissipation
65 W at 230 VAC and 99 W at 115 VAC
Maximum inrush current
Under typical line conditions and over the entire system ambient operating range, the inrush current might reach 45 A per power supply for 40 ms or less
Table 8. Hard Drive PowerHard drive power specifications.
Available Hard Drive Power (per Slot)
Supported hard drive power consumption (continuous)