The tables in this section describe status items that are displayed
on the front panel LCD for each type of component in the chassis.
Table 1. CMC StatusThe following table describes the CMC statuses.
Item
Description
Example: CMC1, CMC2
Name or Location.
No Errors
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings.
Firmware Version
Only displays on an active CMC. Displays Standby
for the standby CMC.
IP4 <enabled, disabled>
Displays current IPv4 enabled state only on an
active CMC.
IP4 Address: <address, acquiring>
Only displays if IPv4 is enabled only on an active
CMC.
IP6 <enabled, disabled>
Displays current IPv6 enabled state only on an
active CMC.
IP6 Local Address: <address>
Only displays if IPv6 is enabled only on an active
CMC.
IP6 Global Address: <address>
Only displays if IPv6 is enabled only on an active
CMC.
MAC: <address>
Displays the CMC's MAC address.
Table 2. Chassis or Enclosure
StatusThe following table describes the chassis or enclosure statuses.
Item
Description
User Define Name
Example: “Dell Rack System”. You can set this
option through the CMC Command Line Interface (CLI) or Web interface.
Error Messages
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings.
Model Number
Example "PowerEdgeM1000e".
Power Consumption
Current power consumption in watts.
Peak Power
Peak power consumed in watts.
Minimum Power
Minimum power consumed in watts.
Ambient Temperature
Current ambient temperature in degrees Celsius.
Service Tag
The factory-assigned service tag.
CMC redundancy mode
Non-Redundant or Redundant.
PSU redundancy mode
Non-Redundant, AC Redundant, or DC Redundant.
Table 3. Fan StatusThe following table describes the fan statuses.
Item
Description
Name/Location
Example: Fan1, Fan2, and so on.
Error Messages
If no error then "No Errors" is shown; otherwise
error messages are listed, critical errors first, then warnings.
RPM
Current fan speed in RPM.
Table 4. PSU StatusThe following table describes the PSU statuses.
Item
Description
Name/Location
Example: PSU1, PSU2, and so on.
Error Messages
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings.
Status
Offline, Online, or Standby.
Maximum Wattage
Maximum Wattage that PSU can supply to the system.
Table 5. IOM StatusThe following table describes the IOM statuses.
Item
Description
Name/Location
Example: IOM A1, IOM B1. and so on.
Error Messages
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings. For more information see LCD
Error Messages.
Status
Off or On.
Model
Model of the IOM.
Fabric Type
Networking type.
IP address
Only shows if IOM is On. This value is zero for
a pass through type IOM.
Service Tag
The factory-assigned service tag.
Table 6. iKVM StatusThe following table describes the iKVM statuses.
Item
Description
Name
iKVM.
No Error
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings. For more information see LCD Error
Messages.
Status
Off or On.
Model/Manufacture
A description of the iKVM model.
Service Tag
The factory-assigned service tag.
Part Number
The Manufacturer part number.
Firmware Version
iKVM firmware version.
Hardware Version
iKVM hardware version.
NOTE This information is
dynamically updated
Table 7. Server StatusThe following table describes the server statuses.
Item
Description
Example: Server 1, Server 2, etc.
Name/Location.
No Errors
If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical errors are
listed first, followed by warnings. For more information see LCD Error
Messages.
Slot Name
Chassis slot name. For example, SLOT-01.
NOTE You can set this table
through the CMC CLI or Web interface.
Name
Name of the server, which the user can set through
Dell OpenManage. The name is displayed only if iDRAC has finished
booting, and the server supports this feature, else iDRAC booting
messages are displayed.
Model Number
Displays if iDRAC finished booting.
Service Tag
Displays if iDRAC finished booting.
BIOS Version
Server BIOS firmware version.
Last POST Code
Displays the last server BIOS POST code messages
string.
iDRAC Firmware Version
Displays if iDRAC finished booting.
NOTE iDRAC version 1.01
is displayed as 1.1. There is no iDRAC version 1.10.
IP4 <enabled, disabled>
Displays the current IPv4 enabled state.
IP4 Address: <address, acquiring>
Only displays if IPv4 is enabled.
IP6 <enabled, disabled>
Only displays if iDRAC supports IPv6. Displays
current IPv6-enabled state.
IP6 Local Address: <address>
Only displays if iDRAC supports IPv6 and IPv6
is enabled.
IP6 Global Address: <address>
Only displays if iDRAC supports IPv6 and IPv6
is enabled.
FlexAddress enabled on Fabrics
Only displays if the feature is installed. Lists
the fabrics enabled for this server (that is, A, B, C).
The information in the table is dynamically
updated. If the server does not support this feature, then the following
information does not appear, else Server Administrator options are
as follows:
Option “None” = No strings must be displayed on
the LCD.
Option “Default” = No Effect.
Option “Custom” = Allows you to enter a string name
for the server.
The information is displayed only if iDRAC has
completed booting. For more information on this feature, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command
Line Reference Guide at dell.com/support/manuals.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\