Ensure that you install the system controllers and disk shelves in the appropriate rack locations.
NOTE: The following recommended rack locations support the cabling described in this document. Installing in other locations might require different cable lengths.
The following table lists the recommended locations for installing the system in the rack.
Table 1. DD9400 system with DS60 or DS600 racking locations DD9400 system with DS60 or DS600 racking locations
Component
Configuration
Rack location
Controller location with DS60 or DS600 shelves
Single node or HA primary node
U12-U13
HA standby node
U15-U16
FS25 location with DS60 or DS600 shelves
HA
U28-U29
DS60 or DS600 locations
Single node or HA
U02-U11, U18-U27
Table 2. DD9400 system with ES40 racking locations DD9400 system with ES40 racking locations
Component
Configuration
Rack location
Controller location with ES40 shelves
Single node or high-availability (HA) primary node
Rack 1: U13-U14
HA standby node
Rack 1: U16-U17
FS25 location with ES40 shelves
HA
Rack 1: U40-U41
ES40 locations
Single node or HA
Rack 1 (11 shelves): U01-U12, U19-U39
Rack 2 (3 shelves): U01-U09