CAUTION Data Domain systems are heavy. Always use two people or a mechanical lift to move a system.
CAUTION
The system controller should be installed in the pre-defined location for the system controller in the rack to comply with Data Domain rack mounting guidelines.
Do not apply AC power to the system controller until all expansion shelves and cables are installed.
Ensure the PSNT label, which is in a slot just beneath the power supply on the rear of the chassis is not damaged or snagged during the installation of the system into the rack.
Steps
From the front of the rack, lift the chassis to install the system in the rack in the correct location.
Slide the unit onto the rails and push it fully into the cabinet until the mounting holes on the unit are flush with the NEMA channel.
Secure the unit to the NEMA channel and rails using four screws, two on each side.
Check the PSNT label in the slot just beneath the power supply at the rear of the chassis.