Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

Dell PowerProtect Cyber Recovery 19.14 Alerts Reference Guide

PDF

Critical system alerts

The following table lists the Cyber Recovery system alerts with a Critical severity.

Alert ID Message Summary Summary Details Remedy
1001 Unable to unlock the Cyber Recovery Vault. Cyber Recovery was unable to unlock the vault to perform a replication
  1. Check the connections to the firewall or the storage system.
  2. Verify that there are no changes to any ssh/security/logins to the storage or firewall settings.
  3. Check switch/network connections to and from the vault
1002 Unable to unmount the recovery sandbox from the host. Unable to unmount the recovery sandbox from the application host in the vault.
  1. Verify the mount location and ensure that it is not in use.
  2. Verify that the host is available.
1003 Unable to mount the recovery sandbox to the host. Unable to mount the recovery sandbox to the application host in the vault.
  1. Verify connectivity to the host.
  2. Verify that mount packages are available on the host.
  3. Verify that the directory on which to mount the sandbox is not in use.
1004 Unable to run the job for the policy. Unable to obtain enough information to run the job for the policy. Verify that the policy exists and that the policy definition is complete.
1005 Failed to assign a different role to the user. An attempt was made to assign a different role to the user. Verify the requesting Cyber Recovery admin's permission to assign a different role to the user. Ensure that the Cyber Recovery admin assigns a lesser role to the user; the admin cannot assign a role with greater privileges.
1006 Unable to analyze the point-in-time copy. An error occurred during a point-in-time copy analysis.
  1. Verify that the vault application performing the analysis is accessible.
  2. Verify that the recovery sandbox on storage is accessible to the vault application.
  3. Verify the vault application credentials.
1010 Unable to initiate a replication synchronization into the vault because an admin secured the vault. A replication synchronization cannot be performed because the vault is Secured. The vault is Secured. Contact a Cyber Recovery admin to release the lock on the vault manually.
1011 Failed to update user details. Failed to update user details due to insufficient permissions. Only the Cyber Recovery Security Officer can update details.
1016 The user is suspended for exceeding the maximum login attempts. The user exceeded the maximum login attempts and has been disabled. Contact the Cyber Recovery Security Officer to enable the user account.
1018 The Cyber Recovery license expired. The Cyber Recovery license expired.
  1. Locate the Instance Id of the Cyber Recovery software.
  2. Acquire the license file from Dell Technologies.
  3. Activate the license by using the license file.
1019 The Cyber Recovery license is invalid. The license file provided is invalid.
  1. Locate the Instance Id of the Cyber Recovery software.
  2. Acquire the license file from Dell Technologies.
  3. Activate the license by using the license file.
1026 Unable to run scheduled analysis on policy. Failed to run the scheduled analysis on the policy; apply the following remedies and ensure that all requirements are met.
  1. Ensure that there is at least one point-in-time copy of the policy on which to run the scheduled analysis.
  2. Ensure that the application selected for the analysis has the minimum required version installed.
  3. Ensure all CyberSense application services are up and running.
  4. Ensure that the CyberSense asset includes a DD Boost user if running CyberSense version 7.8 and later.
1029 Unable to initiate the Sheltered Harbor input validation action. An attempt to start a Sheltered Harbor validation job is unsuccessful. Verify that the Sheltered Harbor service is running.
1030 Unable to initiate the Sheltered Harbor data certification action. An attempt to start a Sheltered Harbor certification job is unsuccessful. Verify that the Sheltered Harbor service is running.
1031 Unable to initiate the Sheltered Harbor reporting action. An attempt to start a Sheltered Harbor reporting job is unsuccessful. Verify that the Sheltered Harbor service is running.
1033 The Sheltered Harbor service is unable to send a failed job error indication outside the vault. The Sheltered Harbor service was unable to send a failed job error indication outside the vault to a configured legal entity e-mail. Verify that the Sheltered Harbor service is running
1034 Unable to run scheduled recoveryCheck on policy Unable to run scheduled recoveryCheck on policy Ensure that there is at least one point-in-time copy of the policy on which to run the scheduled recoveryCheck.
1037 Unable to schedule the next run on the DR Backup Schedule Unable to update the next run on the DR Backup Schedule when kicking off the current backup. Verify the health of the Mongo DB service. Try to update the next run on the DR Backup Schedule manually.
1038 Services are down One or more services are down.
  1. Generate a support log bundle.
  2. Restart the services using crsetup.sh --start/--stop.
  3. If services do not come up, contact support.
1042 Password is about to expire Password is about to expire. Update the password.
1043 Password has expired Password has expired. Update the password.
1052 Unable to retrieve the job status from the application selected for analysis. Unable to retrieve jobstatus from the application selected for analysis.
  1. From the Cyber Recovery host, SSH into the CyberSense host selected for analysis.
  2. Verify that all the services used for analysis are up by running dservice status all
  3. Verify that Cyber Recovery is able to connect to the application selected for analysis.
1055 Unable to email generated report. Failed to send report with given email configurations
  1. Verify the mail server configuration on CR support page.
  2. Check if the email is in Allowable Domains in mail server configuration.
  3. Verify that the CR services are up by running 'docker ps' on CR host
1056 A CyberSense to Data Domain network link error has been detected. The CyberSense monitoring thread has detected a network link error within the multilink definition between the CyberSense host and a Data Domain host. Analyze operations involving this multilink definition will not start until all links are active.
  1. Verify that there is a DD Boost user with valid credentials configured on the CyberSense host for at least one of the DD IP addresses in the multilink. configuration.
  2. Verify that the CyberSense host network interface is enabled and working properly.
  3. Verify that the CyberSense host network interface is enabled and working.
  4. Verify that the cabling and switches between the interfaces are working properly.
  5. Verify that each DD IP address in the multilink definition is reachable from the CyberSense host.\n 6. If a hardware issue is preventing the link from becoming active, the link may be removed as a temporary fix while the issue is being addressed. Note that removing a link might cause performance issues with analysis.
1057 A multilink object definition is in an inactive or degraded state. During multilink configuration, a configured multilink object definition in an inactive or degraded state was detected. In the installed version of CyberSense, analyze operations associated with a multilink definition do not start until all links are active
  1. Verify that there is a DD Boost user with valid credentials configured on the CyberSense host for at least one of the DD IP addresses in the multilink configuration.
  2. Verify that the CyberSense host network interfaces in the inactive links are enabled and working properly.
  3. Verify that the DD host network interfaces in the inactive links are enabled and working properly.
  4. Verify that the cabling and switches between the interfaces are working properly.
  5. Verify that each DD IP address in the multilink definition is reachable from the CyberSense host.
  6. If a hardware issue is preventing the link from becoming active, the link may be removed as a temporary fix while the issue is being addressed. Note that removing a link might cause performance issues with analysis.
1058 A multilink object definition is in an inactive/degraded state or links within it are in an inactive state. When attempting to perform an analyze or secure analyze operation, a configured multilink object definition is detected to be in an inactive/degraded state or links within it are detected to be in an inactive state.
  1. Verify that the CyberSense host network interfaces in the inactive links are enabled and working properly.
  2. Verify that the Data Domain host network interfaces in the inactive links are enabled and working properly.
  3. Verify that the cabling and switches between the interfaces are working properly.
  4. erify that there is a ddboost user configured on the CyberSense host for at least one of the Data Domain IP addresses contained in the multilink configuration.
  5. If a hardware issue is preventing the link from becoming active, the link may be removed as a temporary fix while the issue is being addressed. Note that removing a link might cause performance issues with analysis
1059 A multilink object definition is marked as failed because it is found on the Cyber Recovery system but not on the CyberSense system. The CyberSense monitoring thread has detected that a multilink object definition exists on the Cyber Recovery system but does not exist on the CyberSense system. The multilink object definition is marked as failed. Analyze operations using this multilink definition will not start.
  1. In the UI, go to the CyberSense assets page and use the Edit/Configure option for the Interface Links to view the configured multilink object definitions.
  2. Resubmit the multilink object definition that is marked as failed.
  3. Add or verify DD Boost users on the CyberSense system.
  4. Verify link connectivity on the Cyber Recovery system after approximately 5 minutes.
1062 A failure occurred while creating default multilink object definitions. The 'AnalyzeIndexAsID' field of one or more previously analyzed policies could not be updated. When attempting to create default multilink object definitions, the 'AnalyzeIndexAsID' field of one or more previously analyzed policies could not be updated. This field is used to consistently identify policies on the CyberSense server before and after upgrade to multilink and may cause long analysis times and licensing overdraft issues if not properly updated. Contact support engineering to fix this issue before running analyze operations on CyberSense 8.2 systems.
1063 A CyberSense-to-DD network link error has been detected. The CyberSense monitoring thread has detected a network link error in the multilink definition between the CyberSense host and a DD host. Analyze operations involving this multilink definition might run longer than expected due to the inactive link.
  • Verify that there is a DD Boost user with valid credentials configured on the CyberSense host for at least one of the DD IP addresses in the multilink configuration
  • Verify that the CyberSense host network interface is enabled and working properly.
  • Verify that the DD host network interface is enabled and working properly.
  • Verify that the cabling and switches between the interfaces are working properly.\n 5. Verify that each DD IP address in the multilink definition is reachable from the CyberSense host.
1064 A multilink object definition is in an inactive or degraded state. During multilink configuration, a configured multilink object definition in an inactive or degraded state was detected. Analyze operations involving this multilink definition will not run if it is inactive or might run longer than expected if it is degraded.
  • Verify that there is a DD Boost user with valid credentials configured on the CyberSense host for at least one of the DD IP addresses contained in the multilink configuration.
  • Verify that the CyberSense host network interfaces in the inactive links are enabled and working properly.
  • Verify that the DD host network interfaces in the inactive links are enabled and working properly.
  • Verify that the cabling and switches between the interfaces are working properly.
  • Verify that each DD IP address in the multilink definition is reachable from the CyberSense host.
1065 A multilink object definition is in an inactive state or all the links in the definition are in an inactive state. When attempting to perform an analyze or secure analyze operation, a configured multilink object definition in an inactive state is detected; or all the links in the definition are inactive.
  • Verify that there is a DD Boost user with valid credentials configured on the CyberSense host for at least one of the DD IP addresses in the multilink configuration.
  • Verify that the CyberSense host network interfaces in the inactive links are enabled and working properly.
  • Verify that the DD host network interfaces in the inactive links are enabled and working properly.
  • Verify that the cabling and switches between the interfaces are working properly.
  • Verify that each DD IP address in the multilink definition is reachable from the CyberSense host.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\