Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Boot Optimized Storage Solution-N1 User's Guide

Technical specifications of BOSS-N1 Monolithic, BOSS-N1 Modular ET, and BOSS-N1 Modular controllers

The following table lists the technical specifications of BOSS-N1 Monolithic, BOSS-N1 Modular, and BOSS-N1 Modular ET controllers :

Table 1. Technical specifications of BOSS-N1 Monolithic and BOSS-N1 Modular ETThis table describes the technical specifications of BOSS-N1 Monolithic, BOSS-N1 Modular, and BOSS-N1 Modular ET controllers.
Function or feature BOSS-N1 Monolithic BOSS-N1 Modular ET BOSS-N1 Modular
Hot–plug of NVMe M.2 drives Yes No No
LED activity of M.2 drives Yes No No
Secure firmware update Yes Yes Yes
RAID levels Single drive RAID 0 and dual drive RAID 1 Single drive RAID 0 and dual drive RAID 1 Single drive RAID 0 and dual drive RAID 1
Stripe size Supports default 128 K stripe size only Supports default 128 K stripe size only Supports default 128 K stripe size only
Battery backup unit No No No
Non–volatile cache No No No
Virtual disk cache function Write-through Write-through Write-through
Maximum number of virtual disks 1 1 1
Maximum number of drives supported 2 2 2
Support for non–RAID disks No No No
Drive types M.2 NVMe M.2 NVMe M.2 NVMe
PCIe support Gen 3 Gen 3 Gen 3
Disk cache policy Drive default Drive default Drive default
Configuration (HII) Yes Yes Yes
Full initialization No No No
Fast initialization Yes
NOTE:By default, fast initialization is performed when you create a virtual disk.
Yes
NOTE:By default, fast initialization is performed when you create a virtual disk.
Yes
NOTE:By default, fast initialization is performed when you create a virtual disk.
Background initialization No No No
RAID 0 Yes (single drive RAID 0) Yes (single drive RAID 0) Yes (single drive RAID 0)
RAID 1 Yes Yes Yes
Single non–RAID No No No
Dual non–RAID No No No
Foreign import Yes
NOTE:iDRAC user interface does not support importing a foreign VD. Use HII or delete the VD.
Yes
NOTE:iDRAC user interface does not support importing a foreign VD. Use HII or delete the VD.
Yes
NOTE:iDRAC user interface does not support importing a foreign VD. Use HII or delete the VD.
Consistency check No No No
Patrol-read No No No
Load balance N/A N/A N/A
Rebuild Yes Yes Yes
Hot-spare No No No
Change rebuild priority/rate No No No
Virtual disk write-back/read-ahead cache No
NOTE:BOSS-N1 does not support controller cache.
No
NOTE:BOSS-N1 does not support controller cache.
No
NOTE:BOSS-N1 does not support controller cache.
Battery support N/A
NOTE:BOSS-N1 does not support a battery.
N/A
NOTE:BOSS-N1 does not support a battery.
N/A
NOTE:BOSS-N1 does not support a battery.
Non–RAID disk cache policy Yes
NOTE:Operating system controlled or device defaults.
Yes
NOTE:Operating system controlled or device defaults.
Yes
NOTE:Operating system controlled or device defaults.
SMART Info Yes
NOTE:Use the BOSS-N1 CLI to retrieve the SMART information from the drives.
Yes
NOTE:Use the BOSS-N1 CLI to retrieve the SMART information from the drives.
Yes
NOTE:Use the BOSS-N1 CLI to retrieve the SMART information from the drives.
Physical disk hot–plug Yes No No
Virtual disk expansion No No No
Virtual disk slicing No No No
Virtual disk migration Yes
NOTE:On a new controller, virtual disks must be imported from HII before presented to operating system.
Yes
NOTE:On a new controller, virtual disks must be imported from HII before presented to operating system.
Yes
NOTE:On a new controller, virtual disks must be imported from HII before presented to operating system.
Split mirror No
NOTE:Power off the system and migrate one physical disk to another system and continue rebuild.
No
NOTE: Power off the system and migrate one physical disk to another system and continue rebuild.
No
NOTE: Power off the system and migrate one physical disk to another system and continue rebuild.
Non–RAID migration Not applicable Not applicable Not applicable
Legacy BIOS mode No No No
Add on driver for data path (operating system device driver) No No No
4 K native drive support No No No
TRIM and UNMAP virtual disk No No No
TRIM and UNMAP non–RAID physical disk No No No
Self-Encrypting Drives (SEDs) support Yes Yes Yes
Cryptographic erase (sanitize) Yes
NOTE:If drive supports Sanitize Crypto Erase. No other encryption support from controller or drive.
Yes
NOTE:If drive supports Sanitize Crypto Erase. No other encryption support from controller or drive.
Yes
NOTE:If drive supports Sanitize Crypto Erase. No other encryption support from controller or drive.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\