In the BIOS, access
Serial Communication to view details.
The serial port is optional for the
Dell APEX Cloud Platform MC-660. The
Serial Communication option is applicable only if the serial COM port is installed in the system.
Steps
To view the
Serial Communication screen, power on the system, and then press
F2.
Click
System Setup Main Menu,
System BIOS, and then
Serial Communication. The following table describes the options available under Serial Communication.
Table 1. Serial Communication detailsThis table describes the options available in the Serial Communication section of the BIOS.
Option
Description
Serial Communication
Enables the serial communication options. Selects serial communication devices (Serial Device 1 and Serial Device 2) in the BIOS. You can also enable the BIOS console redirection and specify the port address. The options available for System without serial COM port (DB9) are:
On without Console Redirection,
On with Console Redirection, and
Off. By default, this option is set to
On without Console Redirection.
Serial Port Address
Enables you to set the port address for serial devices. By default, this option is set to either
COM1 or
COM2 for the serial device
(COM1=0x3F8,COM2=0x2F8) and set to
COM1.
NOTE:For the Serial Over LAN (SOL) feature, you can only use Serial Device 2. To use console redirection by SOL, configure the same port address for console redirection and the serial device.
Each time the system boots, the BIOS synchronizes the serial MUX setting that is saved in iDRAC. The serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the BIOS setup utility may not revert the serial MUX setting to the default setting of Serial Device 1.
External Serial Connector
This option allows you to associate the External Serial Connector to:
Serial Device 1,
Serial Device 2, or
Remote Access Device. By default, this option is set to
Serial Device 1.
NOTE:Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.
Each time the system boots, the BIOS synchronizes the serial MUX setting that is saved in iDRAC. The serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the BIOS setup utility may not revert the serial MUX setting to the default setting of Serial Device 1.
Failsafe Baud Rate
Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. By default, this option is set to
115200.
Remote Terminal Type
Sets the remote console terminal type. By default, this option is set to
VT100/VT220.
Redirection After Boot
Enables or disables the BIOS console redirection when the operating system is loaded. By default, this option is set to
Enabled.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\