Dell EMC PowerEdge XR11 Technical Specifications

Environmental specifications

The PowerEdge XR11 system operates in these environmental categories: ASHRAE A2/A3/A4 and Rugged.
NOTE:For additional information about environmental certifications, see the Product Environmental Datasheet that is located with the Documentation > Regulatory Information on www.dell.com/support/home.
Table 1. Continuous operation specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft).
Table 2. Continuous operation specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft).
Table 3. Continuous operation specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft).
Table 4. Continuous operation specifications for Rugged This table describes the operational climatic range for category A4.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) (-5)–55°C (23–131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/80 m (1.8°F/410 Ft) above 900 m (2953 Ft).
Table 5. Common environmental specifications for ASHRAE A2, A3, A4, and Rugged This table describes the shared requirements across all categories.
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation). 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40°C to 65°C (-104°F to 149°F).
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet).
Maximum operational altitude 3,048 meters (10,000 feet).
Table 6. Maximum vibration specifications for the system This table shows the maximum vibration specifications for the system.
Maximum vibration Specifications
Operating MIL-STD-810H, Method 514.8, 1.04 Grms, 2-500 Hz, Random Vibration, Figure 514.8D-11
Storage
  • MIL-STD-810H, Method 514.8, Category 4, Figure 514.8C-2, 10 -500 Hz, 60 minutes/axis
  • MIL-STD-810H, Method 514.8, Category 24, Figure 514.8E-1, 20-2000 Hz, 60 minutes/axis
Table 7. Maximum shock pulse specifications for the systemThe maximum shock specification of an operational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating
  • MIL-STD-810H, Method 516.8, Procedure I, 11ms, 20G
  • MIL-STD-810H, Method 516.8, Procedure I, 11ms, 40G (SSD),
Operating (Navy) MIL-DTL-901E, Grade A, Class 2, Type A, in approved military transit case
Storage
  • MIL-STD-810H, Method 516.8, Procedures I, 11 ms, 40G (with SSD).
  • MIL-STD-810H, Method 516.8, Procedures I, 11 ms, 40G