Dell PowerEdge RAID Controller 12 User’s Guide PERC H965i Adapter, PERC H965i Front, PERC H965i MX, and PERC H965e Adapter

Conditions for replacing the battery (Energy Pack)

A PERC card battery (Energy Pack) is indicated as Failed when the battery stops functioning. If the battery is declared as failed, then all the virtual disks in write-back mode transitions to write-through mode. After replacing the battery, virtual disk transitions back to the write-back mode.