Supporting PowerEdge M640 blade server on the PowerEdge VRTX Chassis.
Updating the physical mapping of TOR switch ports to Dell EMC's 14th generation server ports using LLDP open source package
version 0.7.7.
Unlocking the foreign SEDs from CMC GUI.
Collecting CMC dumplogs as part of the server's SupportAssist tab.
Integrating ZIP open source package version 3.0 for SupportAssist.
Integrating LSOF open source package version 4.86 for SupportAssist.
Monitoring "wear gauge" of SSDs.
Monitoring CMC Fan sensors PWM using RACADM:
getsensorinfo
Integrating the event filter configurations on chassis profile XML file.
Updating the OpenSSL open source package to version 1.0.2K.
Updating the OpenSSH open source package to version 7.4p1.
Updating enterprise OID in the SNMPv3 trap.
Extending SNMP protocol and custom discovery port configuration in GUI.
Extending SNMPv3 trap configuration support in WSMan.
Configuring CMC using WSMan for the following SNMPv3 user attributes:
userAdminSNMPv3Enable
userAdminSNMPv3AuthenticationType
userAdminSNMPv3PrivacyType
Monitoring CMC using WSMan for the following sensors:
Fan sensor speed
Temperature sensor for chassis and servers
Providing racadm commands to initiate/cancel consistency checks of all VDs:
raid ccheckall
raid cancelcheckall
Release 2.23
Federal Information Processing Standards (FIPS) certified. Certification Number: #2861. For details, see www.csrc.nist.gov/groups/STM/cmvp/documents/140-1/140val-all.htm#2861
Release 2.22
Updated the OpenSSL open source package to version 1.0.2j.
Release 2.20
Federal Information Processing Standards (FIPS) 140-2 cryptography capability.
Disabling AC Power Recovery.
Creating a Virtual Disk without initialization of the virtual disk.
Pre-enablement of the following features for Self-Encrypting Drives (SEDs):
Creating, modifying, and deleting the security key — using key identifier and passphrase
Secure erase
Encrypting virtual disks
Unlocking and importing secure foreign virtual disk configuration using RACADM and WSMan
Querying shared storage health using SNMP.
Enabling sPERC Redundancy and setting up Multiple Assignment Mode using WSMan.
Performing racresetcfg from CMC GUI.
Updating the OpenSSL open source package to version 1.0.2f.
Updating the OpenSSH open source package to version 7.1p1.
Updating glibc to version 2.23 to address new security vulnerabilities.
TLS 1.2 and TLS 1.1 by default.
User configuration option to enable TLS 1.0 using RACADM.
SNMPv3 configuration only in RACADM.
Querying the health status of the chassis components using WSMan.
Initiating Quick Deploy of blade through RACADM.
Configuring CMC using WSMan for the following features:
Host Name of Chassis
IP Configuration
DNS
DNS Registration
NTP
Change Default Password
Sending alerts when the power state of an IOM changes and when a power ON of IOM fails.
Populating CMC Device name correctly in the inventory.
Release 2.12
Quick link to the Dell Tech Center page from the CMC web GUI.
Release 2.10
Support for PowerEdge M830 Blade server for PowerEdge VRTX Chassis.
Support for 1100W PSU.
Pre-enablement support for the Shared External Storage expansion (JBOD support).
Firmware and driver refresh of COMMs cards on Dell's 13th generation PowerEdge servers.
Support for Emulex Fibre Channel (FC) 8 HBA adapters.
Capture and replicate chassis configurations through XML based on the Chassis configuration profile.
Support for blinking server identification LED using Quick Link.
Backup or restore through XML based on the chassis configuration profile.
Create and deploy a library of Boot Identity Profiles (boot from iSCSI/SAN configurations) to enable a quick restore of workload
to a spare server.