Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

Dell SmartFabric OS10 User Guide Release 10.5.4

PDF

logging monitor

Set the minimum severity level for logging to the terminal lines.

Syntax
logging monitor severity severity-level
Parameters
severity-level — Set the minimum logging severity level:
  • log-emerg — Set the system as unusable.
  • log-alert — Set to immediate action is needed.
  • log-crit — Set to critical conditions.
  • log-err — Set to error conditions.
  • log-warning — Set to warning conditions.
  • log-notice — Set to normal but significant conditions, the default.
  • log-info — Set to informational messages.
  • log-debug — Set to debug messages.
Default
Log-notice
Command Mode
CONFIGURATION
Usage Information

To reset the monitor severity to the default level, use the no logging monitor severity command. The default severity level is log-notice.

Example
OS10(config)# logging monitor severity log-info