Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell SmartFabric OS10 User Guide Release 10.5.4

PDF

Limitations

  • OS10 does not support PVLANs on the S4200-ON and Z9300-ON series switches, and Z9664F-ON.
  • Enabling multiple PVLAN domains with Virtual Router Redundancy Protocol (VRRP) groups consumes a significant amount of TCAM space.
  • If a packet enters through a VLAN and exits through another VLAN, the VLAN statistics counter increments the ingress VLAN counter twice. The system does not update the egress VLAN counter.
  • IPv6 communication is not supported between devices in:
    • Community and isolated VLANs
    • One community VLAN and another community VLAN
    • Isolated VLANs
  • The maximum number of PVLAN domains that you can create depends of the total hardware resources of the OS10 platform. The total hardware resources used is the sum of hardware resources used for all the PVLAN domains and hardware resources used for attaching the PVLAN ports to the regular VLANs. The following are the maximum hardware resource that can be used on existing OS10 platforms:
    • S5200-ON Series: 7372
    • S4100-ON Series, S6010-ON, and Z9200-ON Series: 14746