iscsi profile-storage

Configures a port for direct connection to a storage device that is not automatically detected by iSCSI.

Syntax
iscsi profile-storage storage-device-name
Parameter
storage-device-name — Enter a user-defined name of a storage array that iSCSI does not automatically detect.
Default
Not configured
Command Mode
INTERFACE
Usage Information
Configure directly attached storage arrays that iSCSI supports if they are not automatically detected. This command is required for storage devices that do not support LLDP. The no version of this command disables the connection.
Example
OS10(conf-if-eth1/1/2)# iscsi profile-storage compellant