Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell SmartFabric OS10 User Guide Release 10.5.4

PDF

show system

Displays system information.

Syntax
show system [brief | node-id]
Parameters
  • brief—View an abbreviated list of the system information.
  • node-id—View the node ID number.
Default
Not configured
Command Mode
EXEC
Usage Information
Starting from Release 10.5.4.0, this command displays the following additional information:
  • Firmware details of the switch such as ONIE version, ONIE firmware updater version, SSD version, DIAG OS version, and PCIe version.
  • Input power, average input power, and average power start time per power supply unit (PSU).
Example
OS10# show system

Node Id              : 1
MAC                  : 54:0f:64:bd:00:00
Number of MACs       : 384
Up Time              : 00:03:58
DiagOS               : 3.00.3.41-2
 
– Unit 1 –
Status                     : up
System Identifier          : 1
Down Reason                : user-triggered
Digital Optical Monitoring : disable
System Location LED        : off
Required Type              : S5232F
Current Type               : S5232F
Hardware Revision          : X01
Software Version           : 10.5.4.0
Physical Ports             : 32x100G, 2x10GbE
BIOS                          : 3.40.0.9-11
ONIE                          : 3.40.1.1-6
FPGA                          : 3.0
BMC                           : 1.05
System CPLD                   : 0.8
Slave CPLD 1                  : 1.0
Slave CPLD 2                  : 1.0
Slave CPLD 3                  : 0.0
Slave CPLD 4                  : 0.0

– Power Supplies –
PSU-ID  Status  Type Power(w) AvgPower(w) AvgPowerStartTime AirFlow  Fan  Speed(rpm)  Status
----------------------------------------------------------------------------------------------
1       up      AC   80       80          01/27/2022-06:52  NORMAL   1    8160        up 

2       up      AC   80       80          01/27/2022-06:52  NORMAL   1    8040        up
 

– Fan Status –
FanTray  Status      AirFlow   Fan  Speed(rpm)  Status
--------------------------------------------------------
1        up          NORMAL    1    9120        up
                               2    8040        up
 
2        up          NORMAL    1    9000        up
                               2    8040        up

3        up          NORMAL    1    9000        up
                               2    8160        up

4        up          NORMAL    1    9000        up
                               2    8160        up
Example (node-id)
OS10# show system node-id 1 fanout-configured

Interface      Breakout capable     Breakout state
-----------------------------------------------------
Eth 1/1/5         No                BREAKOUT_1x1
Eth 1/1/6         No                BREAKOUT_1x1
Eth 1/1/7         No                BREAKOUT_1x1
Eth 1/1/8         No                BREAKOUT_1x1
Eth 1/1/9         No                BREAKOUT_1x1
Eth 1/1/10        No                BREAKOUT_1x1
Eth 1/1/11        No                BREAKOUT_1x1
Eth 1/1/12        No                BREAKOUT_1x1
Eth 1/1/13        No                BREAKOUT_1x1
Eth 1/1/14        No                BREAKOUT_1x1
Eth 1/1/15        No                BREAKOUT_1x1
Eth 1/1/16        No                BREAKOUT_1x1
Eth 1/1/17        No                BREAKOUT_1x1
Eth 1/1/18        No                BREAKOUT_1x1
Eth 1/1/19        No                BREAKOUT_1x1
Eth 1/1/20        No                BREAKOUT_1x1
Eth 1/1/21        No                BREAKOUT_1x1
Eth 1/1/22        No                BREAKOUT_1x1
Eth 1/1/23        No                BREAKOUT_1x1
Eth 1/1/24        No                BREAKOUT_1x1
Eth 1/1/25        Yes               BREAKOUT_1x1
Example (brief)
OS10# show system brief

Node Id           : 1
MAC               : 14:18:77:15:c3:e8

-- Unit --
Unit  Status      ReqType     CurType     Version
----------------------------------------------------------------
1     up          S4148F      S4148F      10.5.1.0

-- Power Supplies --
PSU-ID  Status      Type    AirFlow   Fan  Speed(rpm)  Status
----------------------------------------------------------------
1       up          AC      NORMAL    1    13312       up

2       fail

-- Fan Status --
FanTray  Status      AirFlow   Fan  Speed(rpm)  Status
----------------------------------------------------------------
1        up          NORMAL    1    13195       up

2        up          NORMAL    1    13151       up

3        up          NORMAL    1    13239       up

4        up          NORMAL    1    13239       up
Supported Releases
10.2.0E or later

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\