Full network automation: Deploying a PowerFlex storage-only node

This procedure describes how to deploy a PowerFlex storage-only node with Red Hat Enterprise Linux or CentOS using full network automation option with PowerFlex Manager. The full network automation option will configure changes to physical switches.

About this task

This procedure shows how to deploy a service by creating a new template. A sample template can be used to create a template but does not show the steps here.

Prerequisites

  • To create a new template from a clone, do the following:
    1. Log in to PowerFlex Manager, and click Templates > Add a Template to open Add a Template wizard.
    2. Select Clone an existing PowerFlex Manager template.
    3. Click ? to access the online help.
    4. Follow the instructions on how to add a new template from a sample template.
  • To download the minimal embedded operating system image file, go to CentOS.org and select the minimal ISO image.

Steps

  1. Log in to PowerFlex Manager.
  2. Add OS image to the repository.
    NOTE Skip this step if the OS image is already added to the repository.
    1. Click Settings from menu bar and click Compliance and OS Repositories.
    2. Click the OS Image Repositories tab.
    3. Click Add to open Add OS Image Repository wizard and enter the following:
      OS image information Details
      Repository name Enter <Enter Embedded OS image name>.
      Image type Select Red Hat / CentOS 7.
      Source path and filename Enter http://<server IP>/<folder>/<image name>.iso.
      Username Enter <username>.
      Password Enter <password>.
    4. Validate the path is working correctly, click Test Connection.
    5. Click Add to upload the ISO image.
  3. Click Templates.
  4. Click Add a Template to open the Add a Template page.
    1. Enter the Template Name.
    2. Click Next.
    3. Under Create Template, enter the following details:
      Clone template Details
      Template name Enter <Template name>.
      Template Category

      Select Create New Category..

      Enter a name in the New Category Name box.

      Template Description Enter <Template Description> .

      Example: storage-only nodes with RedHat or CentOS

      Firmware and software compliance Select the latest Intelligent Catalog version from the list.
      Who should have access to the service deployed from this template? Select from list who should have access to this service template.
  5. Click Save.
  6. Click Add Node to open the Node wizard and select Full Network Automation.
    1. Click Continue.
    2. Enter the following details:
      Node Details
      Component name Enter <Embedded OS Image>.
      Number of instances Enter <Number>.
      Related components Select Associate Selected.

      Check checkbox for PowerFlex cluster.

    3. Click Continue.
    4. Under OS Settings, enter the following settings:
      Description Values
      Host name selection Select <appropriate host name selection>.
      OS image Select < Embedded OS Image>.
      OS credentials Select <OS Credential Name>.
      Timezone Select <Time zone>
      NTP server Select <NTP Server>
      Use node for Dell EMC PowerFlex Click checkbox.
      PowerFlex role Select Storage Only.
      Enable compression Select the check box (based on your requirement).
      Enable encryption Select the check box (based on your requirement).
      Enable replication Select the check box (based on your requirement).
      Switch port configuration Select Port Channel (LACP enabled)
      Teaming and bonding configuration Select Mode4 (IEEE 802.3ad policy)
    5. Under SVM OS Settings, enter the details within the following table:
      SVM OS settings Details
      Host name selection Select < appropriate host name selection >.
      Host name template Enter < host name template >.
      OS credentials Select < OS Credentials >.
      NTP server Enter < IP address >.
    6. Under Hardware Settings, enter the details within the following table:
      Hardware settings Details
      Target boot device Select Local Flash Storage for DellEMC PowerFlex.
      Node pool Select <pool name >.
    7. Under BIOS Settings, enter the details within the following table:
      BIOS settings Details
      System profile Select Performance.
      User accessible USB ports Select All Ports On.
      Number of cores per processor Select All.
      Virtualization technology Select Enabled.
      Logical processor Select Enabled.
      Execute disable Select Enabled.
      Node interleaving Select Enabled.
    8. Under Network Settings, follow the steps below to add interfaces.
    9. Click Add New Interface to create the first interface.
    10. Under Interface 1, enter the following details:
      Network settings Details
      Port layout Select Two port 25 gigabit.
    11. Under Port 1, click Choose Networks to open Interface 1 Port 1 Network Configuration window.
    12. Select the checkboxes for the following networks:
      Selected networks Description
      powerflex-data2-<vlanid > Powerflex-Data2
      powerflex-data4-<vlanid > (if required) Powerflex-Data4
      Powerflex-mgmt-<vlanid > Powerflex-Management
      powerflex-prod-<vlanid> Production Network
    13. Click >> to add the selected networks to the right column and click Save.
    14. Under Port 2, click Choose Networks to open Interface 1 Port 2 Network Configuration window.
    15. Select the checkboxes for the following networks:
      Selected networks Description
      powerflex-data1-<vlanid > Powerflex-Data1
      powerflex-data3-<vlanid > (if required) Powerflex-Data3
    16. Click >> to add the selected networks to the right column and click Save.
    17. Click Add New Interface to create the second interface.
    18. Under Interface 2, enter the following details:
      Hardware settings Details
      Port Layout Select Two port 25 gigabit.
    19. Under Port 2, click Choose Networks to open Interface 2 Port 1 Network Configuration window.
    20. Select the checkboxes for the following networks:
      Selected networks Description
      powerflex-data2-<vlanid > Powerflex-Data2
      powerflex-data4-<vlanid > (if required) Powerflex-Data4
      Powerflex-mgmt-<vlanid > Powerflex-Management
      pxe-<vlanid> PXE Network
    21. Click >> to add the selected networks to the right column and click Save.
    22. Under Port 2, click Choose Networks to open Interface 2 Port 2 Network Configuration window.
    23. Select the checkboxes for the following networks:
      Selected networks Description
      powerflex-data1-<vlanid > Powerflex-Data1
      powerflex-data3-<vlanid > (if required) Powerflex-Data3
    24. Click >> to add the selected networks to the right column and click Save.
    25. Click Validate Settings, if there are any errors, correct them and click Close.
    26. Click Save to complete the clone creation.
  7. Create the clusters.
    1. Click Add Cluster to create PowerFlex Cluster.
    2. Click Component Name > PowerFlex Cluster.
    3. Select Associate All or Associate Selected.
    4. Click Continue.
    5. Under PowerFlex Settings, enter the details within the following table:
      PowerFlex settings Details
      Target PowerFlex Gateway Select < New Target PowerFlex Gateway VM >.
      Protection domain name Select Auto generate protection domain name (Recommended).
      Protection domain name template Leave as default: PD-${num}
      Acceleration pool name
      NOTE Only available if compression is enabled.
      Select Auto generate acceleration pool name (Recommended).
      Acceleration pool name template
      NOTE Only available if compression is enabled.
      Leave as default: Site-AP-${num}
      Storage pool name Select Auto generate storage pool name (Recommended).
      Number of storage pools Select < number >.
      Storage pool name template Leave as default.
      Granularity
      NOTE Only available if compression is enabled.
      Select < Fine or Medium >.
      Enable fault sets Check box if fault sets need to be enabled.
      NOTE If the PowerFlex configuration includes fault sets, contact Dell EMC support for assistance. Do not go to the procedure until you have received guidance from a support representative.
    6. Click Save.
  8. In the Template Information box, click Publish Template.
  9. In the pop-up, click Yes.
  10. On the Storage Template page, under Template Information, click Deploy and select the following:
    Deploy settings Details
    Select published template Select < Current Name of Template >.
    Service name Enter < Service Name >.
    Service description Enter < Service Description >.
    Firmware and software compliance Select the latest Intelligent Catalog version from list.
    Who should have access to the service deployed from this template Select from list who should have access to this service template.
  11. Click Next to Deployment setting page.
  12. Validate settings and click Next to Schedule Deployment page.
  13. Leave default to Deploy Now.
  14. Click Next.
  15. Verify the summary page and click Finish.