CurrentReading
|
integer
|
Yes
|
The current value indicated by the Sensor
|
DeviceDescription
|
String
|
Yes
|
A string that contains the friendly Fully Qualified Device Description (FQDD), which is a property that describes the device and its location.
|
ElementName
|
String
|
Yes
|
The user-friendly name for this instance.
|
FQDD
|
String
|
Yes
|
The property shall represent Fully Qualified Device Description (FQDD).
|
LowerThresholdCritical
|
Integer
|
Yes
|
The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between LowerThresholdCritical and LowerThresholdFatal, the CurrentState is Critical.
|
LowerThresholdNonCritical
|
Integer
|
Yes
|
The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If Current Reading is between LowerThresholdNonCritical and Upper ThresholdNonCritical, the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical, the CurrentState is NonCritical.
|
PrimaryStatus
|
String
|
Yes
|
PrimaryStatus provides a high-level status of the device.
|
RateUnits
|
String
|
Yes
|
Specifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). This is true unless this property (RateUnits) has a value other than "None". For example, if BaseUnits is Volts and the UnitModifier is -6, the units of the values returned are MicroVolts. But, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. Any implementation of CurrentReading must be qualified with either a Counter or a Gauge qualifier, depending on the characteristics of the sensor being modeled. The property is not applicable.
|
ReadingUnits
|
String
|
Yes
|
This property represents units of the current reading value, such as Degrees Celsius. This is the base unit of the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the UnitModifier is -6, the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
|
State
|
String
|
Yes
|
This property displays the current state of the device.
|
UnitModifier
|
Integer
|
Yes
|
The unit multiplier for the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the Unit Modifier is -6, the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
|
UpperThresholdCritical
|
Integer
|
Yes
|
The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between UpperThresholdCritical and UpperThresholdFatal, the CurrentState is Critical.
|
UpperThresholdNonCritical
|
Integer
|
Yes
|
The threshold values of the sensor specify the ranges (minimum and maximum values) for determining whether the Sensor is operating under Normal, NonCritical, Critical, or Fatal conditions. If the CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, the Sensor is reporting a normal value. If the CurrentReading is between UpperThresholdNonCritical and UpperThresholdCritical, the CurrentState is NonCritical.
|