Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

VXLAN and BGP EVPN Configuration Guide for Dell EMC SmartFabric OS10 Release 10.5.2

PDF

Specify the controller reachability information

In OS10 VTEP, the controller configuration command initializes a connection to an OVSDB-based controller.

OS10 supports only one controller connection at a time.

NOTE Currently, the only supported OVSDB-based controller is NSX.
To configure an OVSDB controller on the OS10 VTEP:
  1. Enable VXLAN in CONFIGURATION mode.
    OS10(config)# nve
  2. Changes the mode to CONFIGURATION-NVE-OVSDB from where you can configure the controller parameters.
    OS10(config-nve)# controller ovsdb
  3. Specify the IP address, OVSDB controller port, and SSL as a secure connection protocol between the OS10 VTEP and the controller in CONFIGURATION-NVE-OVSDB mode.
    OS10(config-nve-ovsdb)# ip ip-address port port-number ssl
    The range of port-numberis from 0 to 65535. Configure the port-number as 6640 and the connection type as SSL.
  4. (Optional) Specify a time interval, in milliseconds (ms). This is the duration the switch waits between the connection attempts to the controller.
    OS10(config-nve-ovsdb)# max-backoff interval
    The range is from 1000 to 180,000 ms. The default is 8000 ms.
OS10# configure terminal
OS10(config)# nve
OS10(config-nve)# controller ovsdb
OS10(config-nve-ovsdb)# ip 10.11.66.110 port 6640 ssl 