VLT0100

Message
Processor module arg1 voltage is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0101

Message
Processor module arg1 voltage is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
LCD Message
Processor module <name> voltage is outside of range. Contact support
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0102

Message
Processor module arg1 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0103

Message
Processor module arg1 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
LCD Message
Processor module <name> voltage is outside of range . Contact support
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0104

Message
Processor module arg1 voltage is outside of range.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Processor module <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0105

Message
Processor module arg1 voltage is within range.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0200

Message
The system board arg1 voltage is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0201

Message
The system board arg1 voltage is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The system board <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0202

Message
The system board arg1 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0203

Message
The system board arg1 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The system board <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0204

Message
The system board arg1 voltage is outside of range.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
System board voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0205

Message
The system board arg1 voltage is within range.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0206

Message
The memory module arg1 arg2 voltage is less than the lower warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0207

Message
The memory module arg1 arg2 voltage is less than the lower critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0208

Message
The memory module arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0209

Message
The memory module arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0210

Message
The memory module arg1 arg2 voltage is outside of range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <number> <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0211

Message
The memory module arg1 arg2 voltage is within range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0212

Message
The disk drive bay arg1 voltage is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0213

Message
The disk drive bay arg1 voltage is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0214

Message
The disk drive bay arg1 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0215

Message
The disk drive bay arg1 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0216

Message
The disk drive bay arg1 voltage is outside of range.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0217

Message
The disk drive bay arg1 voltage is within range.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0218

Message
The arg1 voltage is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0219

Message
The arg1 voltage is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0220

Message
The arg1 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0221

Message
The arg1 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
The <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0222

Message
The arg1 voltage is outside of range.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Internal voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0223

Message
The arg1 voltage is within range.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0224

Message
The memory module arg1 voltage is less than the lower warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0225

Message
The memory module arg1 voltage is less than the lower critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0226

Message
The memory module arg1 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0227

Message
The memory module arg1 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0228

Message
The memory module arg1 voltage is outside of range.
Arguments
  • arg1 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
Memory module <name> voltage is outside of range. Contact support
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0229

Message
The memory module arg1 voltage is within range.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0230

Message
The mezzanine card arg1 arg2 voltage is less than the lower warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0231

Message
The mezzanine card arg1 arg2 voltage is less than the lower critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0232

Message
The mezzanine card arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0233

Message
The mezzanine card arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0234

Message
The mezzanine card arg1 arg2 voltage is outside of range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0235

Message
The mezzanine card arg1 arg2 voltage is within range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0300

Message
CPU arg1 arg2 voltage is less than the lower warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the processor to fail to operate.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0301

Message
CPU arg1 arg2 voltage is less than the lower critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. When the critical threshold is crossed, the processor will fail to operate. The system may power down.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> <name> voltage is outside of range. Reseat CPU
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0302

Message
CPU arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other electronic components inside the system.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
Trap/EventID
2170
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0303

Message
CPU arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other system electrical components. The system may power down.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> <name> voltage is outside of range. Reseat CPU
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0304

Message
CPU arg1 arg2 voltage is outside of range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
Voltages outside the allowable range may damage electrical components or may cause the system to shutdown.
Recommended Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
2169
LCD Message
CPU <number> voltage is outside of range. Reseat CPU.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT0305

Message
CPU arg1 arg2 voltage is within range.
Arguments
  • arg1 = number
  • arg2 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
Trap/EventID
2171
LCD Message
No LCD message display defined.
Initial Default
IPMI Alert;LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

VLT400

Message
The arg1 sensor has failed with a value arg2 Volts.
Arguments
  • arg1 = sensor name
  • arg2 = voltage
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5150
Server Administrator Trap ID
Not Applicable

VLT401

Message
Unable to read arg1 sensor value.
Arguments
  • arg1 = sensor name
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
OS Log;None
Server Administrator Event ID
5151
Server Administrator Trap ID
Not Applicable

VLT402

Message
The arg1 sensor has returned to a normal state with a value of arg2 Volts.
Arguments
  • arg1 = sensor name
  • arg2 = voltage
Detailed Description
The voltage sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 3 (Informational)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5152
Server Administrator Trap ID
5152

VLT403

Message
The arg1 sensor state has changed to a warning state with a value of arg2 Volts.
Arguments
  • arg1 = sensor name
  • arg2 = voltage
Detailed Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the preset warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 2 (Warning)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5153
Server Administrator Trap ID
5153

VLT404

Message
The arg1 sensor detected an error with a value of arg2 Volts.
Arguments
  • arg1 = sensor name
  • arg2 = voltage
Detailed Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the preset critical threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5154
Server Administrator Trap ID
5154

VLT405

Message
The arg1 sensor has failed with a value of arg2 Volts.
Arguments
  • arg1 = sensor name
  • arg2 = voltage
Detailed Description
A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2) Re-configure the system to a minimum configuration, and verify if the sensor displays a normal value, otherwise replace the system board. 3) If the sensor identified is a processor voltage sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider.
Category
System Health
Subcategory
VLT = Voltage
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
SNMP Alert;OS Log;None
Server Administrator Event ID
5155
Server Administrator Trap ID
5155

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\