Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.0

PDF

CBL Event Messages

CBL0001

Message
Backplane arg1 power cable disconnected.
Arguments
  • arg1 = bay ID
Detailed Description
A backplane signal cable was detected, but the accompanying power cable was not present.
Recommended Response Action
Reconnect or replace the power cable. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0002

Message
Backplane arg1 signal cable disconnected.
Arguments
  • arg1 = bay ID
Detailed Description
A backplane power cable was detected, but the accompanying signal cable was not present.
Recommended Response Action
Reconnect or replace the signal cable for the backplane identified in the message. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0003

Message
Backplane arg1 arg2 cable is disconnected.
Arguments
  • arg1 = bay ID
  • arg2 = cable name
Detailed Description
The backplane cable identified in the message is disconnected or no cable is detected.
Recommended Response Action
Reconnect or replace the cable identified in the message. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
Trap/EventID
2393
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0004

Message
The arg1 cable is incorrectly connected to backplane arg2 connector arg3 .
Arguments
  • arg1 = cable name
  • arg2 = bay ID
  • arg3 = connector name
Detailed Description
The cable identified in the message is incorrectly connected to the backplane connector.
Recommended Response Action
Make sure the cable identified in the message is cabled correctly. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0005

Message
Backplane arg1 arg2 connector incorrectly connected to the motherboard SATA controller.
Arguments
  • arg1 = bay ID
  • arg2 = connector name
Detailed Description
The backplane connector identified in the message is incorrectly connected to the motherboard SATA controller.
Recommended Response Action
Make sure the cable identified in the message is cabled correctly. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0006

Message
Unsupported backplane arg1 configuration: Multiple RAID controllers cannot be connected to the same backplane.
Arguments
  • arg1 = bay ID
Detailed Description
Each server model only supports a certain set of backplane configurations. For unified backplanes or split mode capable backplanes that are in unified mode, multiple controllers cannot be connected to the same backplane. In unified backplane situations any controller besides the first will not be operational.
Recommended Response Action
Make sure that only one RAID controller is connected to the backplane. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

CBL0007

Message
Backplane arg1 arg2 cable and backplane arg3 arg4 cable are swapped.
Arguments
  • arg1 = bay ID
  • arg2 = cable name
  • arg3 = bay ID
  • arg4 = cable name
Detailed Description
The backplane cables identified in the message need to be connected to the correct backplane bays.
Recommended Response Action
Make sure the cables identified in the message are cabled correctly. If the issue persists, contact your service provider.
Category
System Health
Subcategory
CBL = Cable
Severity
Severity 1 (Critical)
LCD Message
No LCD message display defined.
Initial Default
LC Log
Server Administrator Event ID
Not Applicable
Server Administrator Trap ID
Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\