Dell PowerVault ME5 Series Storage System Deployment Guide

IO Module LEDs

IOM status is monitored by the LEDs located on the face plate. The following table describes LED behaviors for expansion enclosure IOMs.

Table 1. Expansion enclosure IOM LEDs
LED Description Color Status

Hardware fault icon

Module fault Amber On
  • Ops panel undergoing 5s test
  • Rear panel area module fault: IOM, fan, PSU, when paired with module fault LED
  • Drive module hardware fault, paired with drive fault LED
Flashing
  • Unknown, invalid, or mixed module type, such as drive module or PSU
  • Vital product data (VPD) configuration error or I2C bus failure
Off—IOM functioning properly

Power icon

Power on or standby Green On—IOM power is on
Amber On—Part of standby sequence as IOM comes online
None Off—IOM power is off

Unit identification icon

Unit identification (UID) White On—UID active to locate or identify for service activity
Off—UID not active

12 Gb/s SAS port icon

12 Gb/s SAS port Green On—Connected, link is up
Off—Not connected or link is down
Amber On—Critical SAS cable fault
Fast flash (1s:1s)—SAS UID active
Slow flash (3s:1s)—Non-critical SAS cable fault
Off—SAS expansion port functioning properly

Ethernet port icon

Ethernet port --- Ethernet port is disabled