The Module Fault LED on the Ops panel lights amber to indicate a fault for the problems listed in the following table:

NOTE All alarms also report through SES.
Table 1. Troubleshooting 2U alarm conditions2U alarm conditions
Status Severity Alarm
PCM alert – loss of DC power from a single PCM Fault – loss of redundancy S1
PCM fan fail Fault – loss of redundancy S1
SBB module detected PCM fault Fault S1
PCM removed Configuration error None
Enclosure configuration error (VPD) Fault – critical S1
Low warning temperature alert Warning S1
High warning temperature alert Warning S1
Over-temperature alarm Fault – critical S4
I2C bus failure Fault – loss of redundancy S1
Ops panel communication error (I2C) Fault – critical S1
RAID error Fault – critical S1
SBB interface module fault Fault – critical S1
SBB interface module removed Warning None
Drive power control fault Warning – no loss of disk power S1
Drive power control fault Fault – critical – loss of disk power S1
Drive removed Warning None
Insufficient power available Warning None