The PowerEdge
T630 system supports up to two AC or DC redundant power supply units
(PSUs).
Table 1. PSU specificationsFor 495 W AC, platinum power supply unit, the maximum
heat dissipation is 1908 BTU/hr, frequency is 50/60 Hz, and voltage
range is 100240 V AC autoranging. For 750 W AC platinum PSU, the
maximum heat dissipation is 2891 BTU/hr, frequency is 50/60 Hz, and
voltage range is 100240 V AC autoranging. For 750 W AC titanium PSU,
the maximum heat dissipation is 2843 BTU/hr, frequency is 50/60 Hz,
and voltage range is 200240 V AC autoranging. For 1100 W AC platinum
PSU, the maximum heat dissipation is 4100 BTU/hr, frequency is 50/60
Hz, and voltage range is 100-240 V AC autoranging. For 1100 W DC PSU,
the maximum heat dissipation is 4416 BTU/hr and the voltage range
is – (4860) V DC. For 750 W DC platinum PSU, the maximum heat dissipation
is 2902 BTU/hr, frequency is 50/60 Hz, and voltage range is 100240
V AC and 240 DC. The 750 W DC PSU is applicable to China only.
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
495 W AC
Platinum
1908 BTU/hr
50/60 Hz
100–240 V AC, autoranging
750 W AC
Platinum
2891 BTU/hr
Titanium
2843 BTU/hr
200–240 V AC, autoranging
1100 W AC
Platinum
4100 BTU/hr
100–240 V AC, autoranging
1600 W AC
Platinum
6000 BTU/hr
100–240 V AC, autoranging
1100 W DC (for China only)
NA
4416 BTU/hr
–(48–60) V DC
NOTE: Heat
dissipation is calculated using the PSU wattage rating.
NOTE: This system is also
designed to connect to the IT power systems with a phase to phase
voltage not exceeding 230 V.
NOTE: PSUs rated for 1600 W and higher require high-line voltage (200-240 V) to supply their rated capacity.
Data is not available for the Topic