Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

OpenManage Integration for VMware vCenter Version 5.2 User's Guide

Proactive HA events

Based on the components supported by VMware for Proactive HA, the following events are registered by the Dell Inc provider during its registration with vCenter:
Table 1. Dell Proactive HA eventsThe following table lists the Dell Proactive HA events:
Dell Inc provider event Component type Description
DellFanRedundancy Fan Fan redundancy event
DellPowerRedundancy Power supply (PSU) Power redundancy event
DellIDSDMRedundancy Storage IDSDM redundancy event
NOTE When the hosts are added to Proactive HA enabled cluster and if IDSDM components are present, ensure that Internal SD Card Redundancy is configured in the iDRAC settings as Mirror.
For a Proactive HA enabled host, the following Traps are used by OMIVV as a trigger to determine the redundant health of components:
Table 2. Proactive HA eventsThe following table lists the Dell Proactive HA events:
Event name Description Severity
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Power Supply Absent The power supply is absent Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Redundancy Lost Redundancy is lost Critical
Integrated Dual SD Module Information Integrated Dual SD Module (IDSDM) information Info
Integrated Dual SD Module Warning Integrated Dual SD Module warning Warning
Integrated Dual SD Module Failure Integrated Dual SD Module failure Critical
Integrated Dual SD Module Absent Integrated Dual SD Module is absent Critical
Integrated Dual SD Module Redundancy Information Integrated Dual SD Module redundancy information Info
Integrated Dual SD Module Redundancy Degraded Integrated Dual SD Module redundancy is degraded Warning
Integrated Dual SD Module Redundancy Lost Integrated Dual SD Module redundancy is lost Critical
Chassis events
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Redundancy Lost Redundancy is lost Critical