The tables in this section describe status items that are displayed
on the front panel LCD for each type of component in the chassis.
Table 1. CMC StatusThe following table describes the CMC statuses.
Item
Description
Name/Location
Example: CMC1, CMC2.
No Errors
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Firmware Version
Only displays on an active CMC. Displays Standby
for the standby CMC.
IP4 <enabled, disabled>
Displays current IPv4 enabled state only on an
active CMC.
IP4 Address: <address, acquiring>
Only displays if IPv4 is enabled only on an active
CMC.
IP6 <enabled, disabled>
Displays current IPv6 enabled state only on an
active CMC.
IP6 Local Address: <address>
Only displays if IPv6 is enabled only on an active
CMC.
MAC: <address>
Displays the CMC's MAC address.
Table 2. Chassis or Enclosure
StatusThe following table describes the chassis or enclosure statuses.
Item
Description
User Define Name
Example: “Dell Rack System”. This can be configured
using the CMC CLI or Web interface.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Model Number
Example "PowerEdgeM1000".
Power Consumption
Current power consumption in watts.
Peak Power
Peak power consumed in watts.
Minimum Power
Minimum power consumed in watts.
Ambient Temperature
Current ambient temperature in degrees Celsius.
Service Tag
The factory-assigned service tag.
CMC redundancy mode
Non-Redundant or Redundant.
PSU redundancy mode
Non-Redundant, Grid Redundant, or DC Redundant.
Table 3. Fan StatusThe following table describes the fan statuses.
Item
Description
Name/Location
Example: Fan1, Fan2, and so on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
RPM
Current fan speed in RPM.
Table 4. PSU StatusThe following table describes the PSU statuses.
Item
Description
Name/Location
Example: PSU1, PSU2, and so on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Status
Offline, Online, or Standby — Indicates the power
status of a PSU.
Maximum Wattage
Maximum Wattage that PSU can supply to the system.
Table 5. IOM StatusThe following table describes the IOM statuses.
Item
Description
Name/Location
IOM A
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Status
Off or On — Indicates whether the IOM is functioning.
Model
Model of the IOM.
Fabric Type
Networking type.
IP address
Only shows if IOM is turned on. This value is
zero for a pass through type IOM.
Service Tag
The factory-assigned service tag.
Table 6. KVM Mapping
StatusThe following table describes the KVM mapping statuses.
Item
Description
Server <number>
Displays a list of servers to which the KVM can
be mapped.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Mapped
Displays a list of servers mapped to a KVM, if
any.
Slot <number>
Indicates the server slot to which the KVM is
mapped to. Possible values are SLOT-<01 to 04>.
Unmapped
Displayed if the KVM is not mapped to any of the
servers.
Table 7. DVD Mapping
StatusThe following table describes the DVD mapping statuses.
Item
Description
Server <number>
Displays a list of servers to which the DVD can
be mapped.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Mapped
Displays a list of servers mapped to a DVD, if
any.
Slot <number>
Indicates the server slot to which the DVD is
mapped to. Possible values are SLOT-<01 to 04>.
Unmapped
Displayed if the KVM is not mapped to any of the
servers.
Table 8. Blower StatusThe following table describes the blower statuses.
Item
Description
Name/Location
Example: Blower1, Blower2, and so on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
RPM
Current blower speed in RPM.
Table 9. SPERC StatusThe following table describes the SPERC statuses.
Item
Description
SPERC: <number>
Displays the SPERC name in the
format SPERC n, where 'n' is the SPERC number. Example: SPERC 1, SPERC
2, and so on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Working Status
On or Off — Indicates whether the
SPERC is functioning.
Name: <name>
Name of the shared PERC. Example:
SPERC
Health Status
Ok
Firmware Version
SPERC version
Manufacturer
Manufacturer name
State
Offline, Online, or Standby —
Indicates the power status of a SPERC.
Table 10. PCIe Card StatusThe following table describes the PCIe card statuses.
Item
Description
PCIe Card <number>
Displays the PCIe Card name in
the format PCIe Card <n>, where 'n' is the PCIe Card number.
Example: PCIe Card 1, PCIe Card 2, and so on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Working Status
On or Off — Indicates whether
the PCIe Card is functioning.
Name: <name>
Name of the PCIe Card.
Mapped to Server
Mapped or Unmapped.
Table 11. Hard Disk Drive
StatusThe following table describes the hard disk drive statuses.
Item
Description
Hard Disk Drive: <number>
Displays the Hard disk drive name
in the format Hard Disk Drive <n>, where 'n' is the hard
drive number. Example: Hard Disk Drive 1, Hard Disk Drive 2, and so
on.
Error Messages
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related.
Power Status
Spun-Up, Transition, or Spun-Down
— Indicates the power status of a hard disk drive
Manufacturer
Manufacturer name
Capacity
Available Storage capacity of
the Hard Disk Drive in gigabytes (GB)
Firmware version
Firmware version of the Hard Disk
Drive
State
Offline, Online, or Standby — Indicates
the power status of the hard disk drive.
Table 12. Server StatusThe following table describes the server statuses.
Item
Description
Name/Location
Example: Server 1, Server 2, and so on.
No Errors
If there are no errors, No Errors is displayed.
Else, error messages are listed where critical ones are first listed,
and then the warning-related. For more information, see "LCD Error
Messages".
Slot Name
Chassis slot name. For example, SLOT-01.
NOTE You can set this table
through the CMC CLI or CMC Web interface.
Name
Name of the server, which the user can set through
Dell OpenManage. The name is displayed only if iDRAC has finished
booting, and the server supports this feature, else iDRAC booting
messages are displayed.
Model Number
Displays if iDRAC finished booting.
Service Tag
Displays if iDRAC finished booting.
BIOS Version
Server BIOS firmware version.
Last POST Code
Displays the last server BIOS POST code messages
string.
iDRAC Firmware Version
Displays if iDRAC finished booting.
NOTE iDRAC version 1.01
is displayed as 1.1. There is no iDRAC version 1.10.
IP4 <enabled, disabled>
Displays the current IPv4 enabled state.
IP4 Address: <address, acquiring>
Only displays if IPv4 is enabled.
IP6 <enabled, disabled>
Only displays if iDRAC supports IPv6. Displays
current IPv6-enabled state.
IP6 Local Address: <address>
Only displays if iDRAC supports IPv6 and IPv6 is
enabled.
IP6 Global Address: <address>
Only displays if iDRAC supports IPv6 and IPv6 is
enabled.
FlexAddress enabled on Fabrics
Only displays if the feature is installed. Lists
the fabrics enabled for this server (that is, A, B, C).
The information in the table is dynamically
updated. If the server does not support this feature, then the following
information does not appear, else Server Administrator options are
as follows:
Option “None” = No strings must be displayed on the
LCD.
Option “Default” = No Effect.
Option “Custom” = Allows you to enter a string name
for the server.
The information is displayed only if iDRAC has
completed booting. For more information on this feature, see the RACADM Command Line Reference Guide for CMC in PowerEdge VRTX.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\