Compute Only - ESXi
|
Standard ESXi compute-only nodes deployment.
Depends on hyperconverged or storage-only nodes to be deployed first.
|
3
|
0
|
4
|
Compute Only - ESXi 100Gb
|
100 GB networking deployment.
Depends on hyperconverged or storage-only nodes to be deployed first.
|
3
|
0
|
4
|
Compute Only - ESXi - Partial Network
|
Standard ESXi compute-only nodes deployment with partial network automation. The partial network feature allows you to work with unsupported switches. If you choose to use the partial network feature, you give up the error handling and network automation features that are available with a full network configuration that includes supported switches.
Depends on hyperconverged or storage-only nodes to be deployed first.
|
3
|
0
|
4
|
Compute Only - Linux
|
Linux-based compute-only nodes deployment. No volume mapping.
Depends on hyperconverged or storage-only nodes to be deployed first.
|
4
|
0
|
4
|
Compute Only - Linux - Partial Network
|
Standard Linux compute-only nodes deployment with partial network automation. The partial network feature allows you to work with unsupported switches. If you choose to use the partial network feature, you give up the error handling and network automation features that are available with a full network configuration that includes supported switches.
Depends on hyperconverged or storage-only nodes to be deployed first.
|
3
|
0
|
4
|
Hyperconverged
|
Standard hyperconverged nodes deployment.
|
4
|
0
|
4
|
Hyperconverged - 100Gb
|
100 GB networking deployment. Nodes require Mellanox CX5 or CX6 interface cards.
|
4
|
0
|
4
|
Hyperconverged - Compression
|
Compression-enabled deployment.
Requires NVDIMM in nodes.
|
4
|
0
|
4
|
Hyperconverged - Encryption
|
CloudLink encryption deployment. Requires CloudLink Center in environment.
|
4
|
0
|
4
|
Hyperconverged - Leaf-Spine
|
Networking without virtual port channel deployment. This is the most common leaf-spine configuration.
|
4
|
0
|
4
|
Hyperconverged - Partial Network
|
Hyperconverged deployment with partial network automation. The partial network feature allows you to work with unsupported switches. If you choose to use the partial network feature, you give up the error handling and network automation features that are available with a full network configuration that includes supported switches.
|
4
|
0
|
4
|
Hyperconverged - Replication
|
Hyperconverged deployment with replication enabled.
|
4
|
0
|
5
|
Management - CloudLink Center
|
Two node CloudLink Center cluster deployment, for use in encryption templates.
|
0
|
2
|
NA
|
Management - PowerFlex Gateway
|
PowerFlex Gateway VM deployment, for use in all templates.
|
0
|
1
|
4
|
Management - Presentation Server
|
Presentation server VM deployment. The presentation server hosts the PowerFlex GUI.
|
0
|
1
|
NA
|
Storage
|
Standard storage-only nodes deployment.
|
4
|
0
|
4
|
Storage - 100Gb
|
100 GB networking deployment. Nodes require Mellanox CX5 or CX6 interface cards.
|
4
|
0
|
4
|
Storage - Compression
|
Compression-enabled deployment.
Requires NVDIMM in nodes.
|
4
|
0
|
4
|
Storage - Partial Network
|
Partial network deployment. The partial network feature allows you to work with unsupported switches. If you choose to use the partial network feature, you give up the error handling and network automation features that are available with a full network configuration that includes supported switches.
|
4
|
0
|
4
|
Storage - Encryption
|
Encryption-enabled deployment.
|
4
|
0
|
4
|
Storage - Replication
|
Replication-enabled deployment. Configures storage data replicator (SDR) and journal capacity.
|
4
|
0
|
4
|
Storage - Perf, No HA Management
|
Non-HA management deployment.
|
4
|
0
|
4
|