Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge R750 Installation and Service Manual

Removing the BOSS S2 module

The procedure to remove is the BOSS S2 module with 4 x 2.5-inch rear drive module is same.

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in the Before working inside your system.

Steps

  1. Pull and lift the BOSS S2 card carrier retention latch lock to open.
  2. Slide the BOSS S2 card carrier out.
    Figure 1. Removing the BOSS S2 card carrier
    Removing the BOSS S2 card carrier
  3. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the M.2 SSD to the BOSS S2 card carrier.
  4. Slide the M.2 SSD out from the BOSS S2 card carrier.
    Figure 2. Removing the M.2 SSD
    Removing the M.2 SSD
  5. Disconnect the BOSS S2 power and signal cable from the system board.
  6. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the BOSS S2 module on Riser 1.
  7. Slide the BOSS S2 module towards the front of the chassis and lift the module.
    Figure 3. Removing the BOSS S2 module
    This image shows Removing the BOSS S2 module
  8. Remove the BOSS S2 power and signal cable from the BOSS S2 module.
    Figure 4. Removing the BOSS S2 power and signal cable from the BOSS S2 module
    Removing the BOSS power cable and BOSS signal cable from the BOSS S2 module