Below is a sample VBScript that contains details of the
system summary.
'**********************************************************************
'*** Name: SampleSystemSummary.vbs
'*** Purpose: To check
for BIOS Admin/Boot Password on a Dell OMCI client.
'*** Usage:
cscript.exe //nologo SampleSystemSummary.vbs <systemname>
'*** This sample script is provided as an example only, and has not
been
'*** tested, nor is warranted in any way by Dell; Dell
disclaims any
'*** liability in connection therewith. Dell
provides no technical
'*** support with regard to such scripting.
For more information on WMI
'*** scripting, refer to applicable
Microsoft documentation.
'**********************************************************************
Option Explicit
'*** Declare variables
Dim strNameSpace
Dim strComputerName
Dim strClassName
Dim strClassNameBIOS
Dim strKeyValueChassis
Dim objInstance
Dim ColSystem
Dim objWMIService
Dim strMessage
'*** Check that the right
executable was used to run the script and that all parameters were
passed
If (LCase(Right(WScript.FullName, 11)) = "wscript.exe" ) Or _
(Wscript.Arguments.Count < 1) Then
Call Usage()
WScript.Quit
End If
'*** Initialize variables
strNameSpace = "root/dcim/sysman"
strComputerName = WScript.Arguments(0)
strClassName = "DCIM_Chassis"
strClassNameBIOS = "DCIM_BIOSElement"
strKeyValueChassis = "DCIM_Chassis"
'***
Retrieve the instance of DCIM_Chassis class (there should only be
1 instance)
'*** Establish a connection to the dcim\sysman namespace
Set objWMIService = GetObject("winmgmts:{impersonationLevel=impersonate," &_
"AuthenticationLevel=pktprivacy}\\" & strComputerName & "\" &_
strNameSpace)
Set ColSystem=objWMIService.execquery ("Select * from " & strClassName)
For each objInstance in ColSystem
if (objInstance.CreationClassName = strKeyValueChassis) Then
strMessage = "Asset Tag: "
strMessage = strMessage & objInstance.Properties_.Item("Tag").Value
strMessage = strMessage & vbCRLF & "Service Tag: "
strMessage = strMessage & objInstance.Properties_.Item("ElementName").Value
End if
Next
'***
Retrieve all instances of DCIM_BIOSElement (there should only be 1
instance).
Set ColSystem=objWMIService.execquery ("Select * from " & strClassNameBIOS)
For each objInstance in ColSystem
strMessage = strMessage & vbCRLF & "BIOS Version: "
strMessage = strMessage & objInstance.Properties_.Item("Version").Value
Next
'*** Display the results
WScript.Echo strMessage
'*** Sub used to display the
correct usage of the script
Sub Usage()
Dim strMessage
strMessage = "incorrect syntax. You should run: " & vbCRLF & _
"cscript.exe //nologo SampleSystemSummary.vbs <systemname>"
WScript.Echo strMessage
End Sub
'==========================================================================
' End
'==========================================================================