AlertTemperatureProbeWarning (1053)
|
Temperature probe has detected a
warning value.
|
AlertTemperatureProbeFailure (1054)
|
Temperature probe has detected
a failure value.
|
AlertTemperatureProbeNonRecoverable
(1055)
|
Temperature probe has detected
a non-recoverable value.
|
FanProbe (1103)
|
A cooling device has exceeded a
minor threshold.
|
AlertCoolingDeviceFailure (1104)
|
Cooling device sensor has detected
a failure value.
|
AlertCoolingDeviceNonRecoverable (1105)
|
Cooling device sensor has detected
a non-recoverable value.
|
AlertVoltageProbeWarning (1153)
|
Voltage probe has detected a warning
value.
|
AlertVoltageProbeFailure (1154)
|
Voltage probe has detected a failure
value.
|
AlertVoltageProbeNonRecoverable (1155)
|
Voltage probe has detected a non-recoverable
value.
|
CurrentProbe (1203)
|
An electrical current probe has
exceeded a minor threshold.
One of the hard-disk
drive is running out of free space.
|
AlertAmperageProbeFailure (1204)
|
Amperage probe has detected a failure
value.
|
AlertAmperageProbeNonRecoverable (1205)
|
Amperage probe has detected a non-recoverable
value.
|
ChassisIntrusionNormal (1252)
|
Chassis intrusion has returned
to normal.
|
ChassisIntrusion (1254)
|
System chassis intrusion alert.
|
EccMemory (1403)
|
A memory checksum failure has
occurred.
|
RAIDControllerFailure (1801)
|
A RAID controller has failed.
|
RAIDControllerOffline (1802)
|
A RAID controller is offline.
|
RAIDControllerPowerOff (1803)
|
A RAID controller is turned off.
|
AlertRaidControllerDegraded (1804)
|
A Raid controller has degraded.
|
PhysicalDiskDegraded (1811)
|
A physical hard-disk drive is degraded.
|
AlertPhysicalDiskRebuilding (1812)
|
A physical hard-disk drive is rebuilding.
|
PhysicalDiskFailed (1813)
|
A physical hard-disk drive has
failed.
|
PhysicalDiskOffline (1814)
|
A physical hard-disk drive is offline.
|
VitualDiskDegraded (1821)
|
A virtual hard-disk drive is degraded.
|
VirtualDiskRebuilding (1822)
|
A virtual hard-disk drive is rebuilding.
|
VirtualDiskFailed (1823)
|
A virtual hard-disk drive has failed.
|
VirtualDiskOffline (1824)
|
A virtual hard-disk drive is offline.
|
NumberOfDisksIncreased (2030)
|
A hard-disk drive has been added.
|
NumberOfDisksDecreased (2031)
|
A hard-disk drive has been removed.
|
MemorySizeIncreased (2032)
|
The memory size has been increased.
|
MemorySizeDecreased (2033)
|
The memory size has been decreased.
|
DiskCapacity (2034)
|
In the current version, two user-defined
thresholds are used. An event is generated only when the conditions
of both thresholds are met. The first threshold, expressed as an absolute
value in megabytes, specifies the size of the hard-disk drive to be
monitored. Hard-disk drives with a capacity smaller than the specified
size are ignored. The second threshold is expressed as a percentage
of the hard-disk drive size. An event is generated when the available
free space on one of the monitored hard-disk drives falls below this
percentage
|
NumberOfProcessorsIncreased (2035)
|
Number of processors on the system
has increased
|
NumberOfProcessorsDecreased (2036)
|
A processor has been removed.
|
HDD Smart Failure(2037)
|
A hard-disk drive condition has
occurred that may eventually lead to a hard-disk drive failure.
|
DiskSizeIncreased (2038)
|
The size of at least one hard-disk
drive has increased.
|
DiskSizeDecreased (2039)
|
The size of at least one hard-disk
drive has decreased.
|