Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC Configuration Guide for the S3100 Series 9.14.2.4

PDF

Creating a New Stack

Prior to creating a stack, know which unit will be the management unit and which will be the standby unit.

  1. Power up all units in the stack.
  2. Verify that each unit has the same Dell EMC Networking OS version prior to stacking them together.
    EXEC Privilege mode
    show version
  3. Manually configure unit numbers for each unit, so that the stacking is deterministic upon boot up.
    EXEC Privilege mode
    stack-unit stack—unit—number renumber stack—unit—number.
    Renumbering causes the unit to reboot. The stack-unit default for all new units is stack-unit 1.
  4. Configure the switch priority for each unit to make management unit selection deterministic.
    CONFIGURATION mode
    stack-unit stack—unit—number priority priority
  5. Connect the units using stacking cables.
    NOTE There are two fixed mini-SAS stacking connectors on the PSU side. You can connect mini-SAS cables between units to form stacking.
  6. Reload the stack one unit at a time.
    EXEC Privilege mode
    show system brief
    Start with the management unit, then the standby, then each of the members in order of their assigned stack number (or the position in the stack you want each unit to take).
    Allow each unit to completely boot, and verify that the stack manager detects the unit, then power the next unit.

Example of a Syslog

Figure 1. Creating a new stack
Illustration of creating a new S3100 stack.
In the above example, stack unit 1 is the master management unit, stack unit 2 is the standby unit. The cables are connected to each unit.

Reload each unit in the stack. After the reload is complete, the four units come up as a stack with unit 1 as the management unit, unit 2 as the standby unit, and the remaining units as stack-members. All units in the stack can be accessed from the management unit.

NOTE Before executing show commands, you must wait for 10 to 15 seconds for the download-agent process to start.

To view the stack unit information after the reload, use the show system brief command.

DellEMC#show system brief

Stack MAC                  : 34:17:17:18:19:1e
Reload-Type                         : normal-reload [Next boot : normal-reload]

--  Stack Info  --
Unit  UnitType     Status         ReqTyp          CurTyp          Version     Ports
------------------------------------------------------------------------------------
  1   Member       online         S3124F          S3124F          1-0(0-4679)  30
  2   Member       online         S3124           S3124           1-0(0-4679)  30
  3   Member       online         S3124           S3124           1-0(0-4679)  30
  4   Member       online         S3148P          S3148P          1-0(0-4679)  54
  5   Standby      online         S3148           S3148           1-0(0-4679)  54
  6   Member       online         S3148P          S3148P          1-0(0-4679)  54
  7   Member       online         S3124F          S3124F          1-0(0-4679)  30
  8   Member       online         S3124P          S3124P          1-0(0-4679)  30
  9   Member       online         S3124F          S3124F          1-0(0-4679)  30
 10   Member       online         S3148           S3148           1-0(0-4679)  54
 11   Member       online         S3124F          S3124F          1-0(0-4679)  30
 12   Management   online         S3148           S3148           1-0(0-4679)  54

--  Module Info  --
Unit  Module No   Status        Module Type                  Ports
---------------------------------------------------------------------------
  1   1           not present   No Module                     0
  2   1           not present   No Module                     0
  3   1           not present   No Module                     0
  4   1           not present   No Module                     0
  5   1           online        S3148-10GE-2X10BaseT          2
  6   1           not present   No Module                     0
  7   1           not present   No Module                     0
  8   1           not present   No Module                     0
  9   1           not present   No Module                     0
 10   1           online        S3148-10GE-2SFP+              2
 11   1           not present   No Module                     0
 12   1           online        S3148-10GE-2SFP+              2

--  Power Supplies  --
Unit   Bay   Status       Type    FanStatus   FanSpeed(rpm)
---------------------------------------------------------------------------
  1     1    up           UNKNOWN up          NA
  1     2    absent               absent      NA
  2     1    absent               absent      NA
  2     2    up           AC      up          NA
  3     1    absent               absent      NA
  3     2    up           AC      up          NA
  4     1    absent               absent      0
  4     2    up           AC      up          7888
  5     1    up           AC      up          NA
  5     2    absent               absent      NA
  6     1    down         UNKNOWN down        0
  6     2    up           AC      up          7968
  7     1    absent               absent      NA
  7     2    up           AC      up          NA
  8     1    absent               absent      0
  8     2    up           AC      up          3136
  9     1    up           AC      up          NA
  9     2    absent               absent      NA
 10     1    up           AC      up          NA
 10     2    up           AC      up          NA
 11     1    absent               absent      NA
 11     2    up           AC      up          NA
 12     1    up           AC      up          NA
 12     2    down         UNKNOWN absent      NA

--  Fan  Status  --
Unit Bay   TrayStatus  Fan1    Speed   Fan2    Speed
------------------------------------------------------------------------------------
 1    1     up          up      7164    up      7058
 2    1     up          up      6956    up      7058
 3    1     up          up      7164    up      7058
 4    1     up          up      7058    up      7164
 5    1     up          up      7058    up      6956
 6    1     up          up      7058    up      7164
 7    1     up          up      12307   down    0
 8    1     up          up      7164    up      7164
 9    1     up          up      7058    up      7058
10    1     up          up      7164    up      7058
11    1     up          up      7058    up      7058
12    1     up          up      7164    up      7058

Speed in RPM

DellEMC#