Chassis Management Controller Version 2.0 for Dell PowerEdge VRTX User's Guide

Managing PCIe Slots Using RACADM

You can assign or unassign a PCIe slot to a server by using the RACADM commands. Some of the commands are given here. For more information about the RACADM commands, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/Manuals.

  • To view the current assignment of PCIe devices to servers, run the following command:
    racadm getpiecfg -a
  • To view the properties of PCIe devices by using FQDD, run the following command:
    racadm getpciecfg [-c <FQDD>]
    For example, to view the properties of PCIe device 1, run the following command.
    racadm getpciecfg -c PCIE.ChassisSlot.1
  • To assign a PCIe adapter slot to server slot, run the following command:
    racadm setpciecfg assign [-c <FQDD>] [i <server slot>]
  • For example, to assign PCIe slot 5 to server slot 2, run the following command.
    racadm setpciecfg assign -c PCIE.ChassisSlot.5 -i 2
  • To unassign a PCIe slot 3 from a server, run the following command:
    racadm setpciecfg unassign -c pcie.chassisslot.3