症狀
Customer prefers or requires Microsoft Edge.
There is a need to run Unisphere within Microsoft Edge.
原因
Java is no longer supported with Microsoft Edge.
解析度
1. Open Edge, Go to
Settings by clicking three-dot menu on the right side of the top menu bar.
2. Navigate to
Default Browser to Use IE Mode.
3. For option
Allow sites to be reloaded in Internet Explorer mode you can set to either
Default or
Allow mode.
4. Select How and When Sites Will Load in IE Mode.
- If you choose the Default setting presents an option to open Edge in IE mode if you have opened a page in that mode before. (This does not mean that IE mode is the default; this is the default setting in Edge.)
- If you choose Allow, you must restart your browser. You will be able to choose Reload in Internet Explorer mode from the settings and more menu, or by right-clicking the tab and then choosing Open link in new Internet Explorer mode tab.
5. Open Any Pages Requiring IE. When you do, you see a notification about the mode with a switch for making the site always use IE mode. You also see a button to switch to it once you are done browsing the site that requires IE.
How to troubleshoot JAVA issue? Check below instructions:
1] Clear Java cache on a PC
1. Launch Control Panel > Double-click Java. OR Start > Run > Javaws -viewer
2. Click General Tab and click Settings under Temporary Internet Files.
3. Click Delete Files button, and then click OK.
4. Click OK again.
Alternatively, you can run the following command from the Run command (Click Start and then Run)
NOTE: This will only clear java cache and will not uninstall java.
javaws -uninstall
Open Java from control panel OR Run > Javaws -viewer
2] From Advanced tab > Select Do not check (not recommended)
3] From Security tab >Decrease the security level and Edit site list and add the IP address of VNX SPA / SPB / CS, and that should be added like:
https://SPAIP/
http://SPAIP/
https://SPBIP/
http://SPBIP/
https://CSIP/
http://CSIP/
4] Disable proxy settings and use direct connections.
5] Increase Java memory and or runtime parameters
- Unisphere may be unresponsive when using Analyzer on a system with a large configuration (hundreds of LUNs).
- Navigation and handling may appear slower
1. Start > Run > Javaws -viewer
2. From Java tab and click View….
3. Enter –Xmx1024m under Runtime Parameter, which allocates 1024 MB memory for Java. This number can be increased or decreased [512, 256] as you see fit.
受影響的產品
VNX1 Series, VNX2 Series