跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
部分文章編號可能已變更。如果這不是您要找的文章,請嘗試搜尋所有文章。搜尋文章

Dell PowerEdge: Resolve CPU 1 or 2 has an internal error (CPU IERR) on Servers

摘要: The CPU Internal Error (CPU IErr) or CPU Machine Check error is usually not an error of the CPU itself, but a sign that the CPU has detected an error in the system.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

-

原因

-

解析度

 Table of Contents

  1. Description
  2. Identifying a CPU IERR in the System Log
  3. Resolving a CPU IERR
  4. Operating System Issues
 
Description

The CPU Internal Error (CPU IERR) or CPU Machine Check error is usually not an error of the CPU itself. But an indication that the CPU has detected an error in the system, or received an erroneous instruction from a system component. It is caused by a non-CPU event, such as a firmware mismatch, a system BUS interruption or a memory read/write interruption. The error can theoretically be caused by ANY system component, software, or hardware.

This article contains the best practice on dealing with these errors and is valid for all PowerEdge servers.
 
SLN298205_en_US__1icon Warning: Do not remove CPU! CPU IERR errors are rarely caused by a CPU malfunction and the reference to the CPU is solely based on what module reported the error. Despite what you may read on some troubleshooting websites or forums it is imperative that you do not remove the CPU unless trained and equipped to do so.

 

 
Identifying a CPU IERR in the System Event Log

A CPU Internal Error shows in the System Event Log as "CPU 1 has an internal error (IERR)" or "CPU 2 has an internal error (IERR)."

SLN298205_en_US__2DSET-CPUIERR
Figure 1: DSET showing CPU IERR

  
Resolving a CPU IERR

To resolve this error, please follow a structured plan of troubleshooting to determine which component has caused the error and how to resolve it.

1. Check system event log for any other errors occurring around the same time as the CPU IERR.
 
2. If any other errors are identified, resolve these errors first. How to resolve the errors would depend on the error identified.
 
3. Update the BIOS and iDRAC firmware to the latest version.

- Update the BIOS or the iDRAC using the iDRAC interface is explained here - Updating Firmware and Drivers on Dell EMC PowerEdge Server.
- If the iDRAC is not available, other update methods are listed in the following tutorial - How to update firmware remotely using the Integrated Dell Remote Access Controller (iDRAC) web interface

4. Clear System Event log. i.e. in Open Manage Server Administrator or iDRAC (for both, open the event log, scroll to the bottom and press clear log) Old CPU IERR errors will cause an alert after the error has been resolved unless they are cleared from the System Event Log.
 
5. If no errors are found, or the CPU IERR returns, shut down the system, remove the power cable and hold in the server power button for 20 seconds before plugging the power cable back and turning the system on again. This process is known as a Flea Power Drain.

6. If the error still persists, contact the technical support for further assistance. Contact options are provided below.

 


Operating System Issues

Some operating system events, can cause a CPU IERR to be recorded within the System Event Log. These include the following:

  • Fatal kernel errors,
  • Third-party program interactions,
  • Runtime critical stops, or
  • Resource overcommitment.


This is due to the CPU identifying the process as unrecognized and asserting the CPU IERR in response.

If the CPU IERR has been caused by an operating system event the Operating System Event Log should be checked and cross referenced with the Server System Event Log to identify the Operating System event that has caused the CPU IERR. Once this operating system event has been identified, the operating system provider should be contacted to assist with resolution.

 

受影響的產品

PowerEdge, Legacy Server Models, PowerEdge R520, PowerEdge R630, PowerEdge R720, PowerEdge R720XD, PowerEdge R910
文章屬性
文章編號: 000137438
文章類型: Solution
上次修改時間: 16 11月 2022
版本:  5
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。