跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表

PowerEdge: How to remove or replace a Power Supply Unit (PSU)

摘要: Step-by-step instructions to remove and replace the Power Supply Unit (PSU).

本文适用于   本文不适用于 

说明


Replacing a power supply unit is a simple action. If the server has two power supplies configured in redundant mode, which is the default setting, you can remove one without shutting down the server.
The remaining power supply continues to provide the power to the server. In general, all components with an amber removal tool can be unplugged while the server is powered on.
 
Warning: The system requires at least one power supply for normal operation. On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.
 
  1. Disconnect the power cable from the power source and from the power supply unit that you intend to remove, and then remove the cable from the strap.
  2. Press the release latch and slide the power supply unit out of the chassis.
Image of a standard server power supply and indicators for the release latch
1.  Release latch
2. Power supply unit cable connector
3. Power supply unit
4. Connector
5. Power supply unit handle

To insert the new power supply, insert the block in the slot. This operation can be done while the server is powered on.

其他信息

Removing a PowerEdge Power Supply Unit

Duration: 00:00:45
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

受影响的产品

Rack Servers, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640
文章属性
文章编号: 000141313
文章类型: How To
上次修改时间: 23 9月 2024
版本:  12
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。