PowerEdge: How to Update the CMC Firmware on M1000e, FX2, and VRTX Chassis

摘要: This article explains how to perform Chassis Management Controller (CMC) updates using the Web Management Interface of the Management Card on the M1000E, FX2, VRTX Chassis.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

说明

Caution: It is recommended to update the CMC firmware before updating the server component firmware.
 

To download the CMC update, follow the steps below:

  1. Browse to https://www.dell.com/support/home?app=drivers enter your Chassis server model or enter Chassis service tag.
  2. Click Drivers & Downloads Tab
  3. Keyword Chassis Management Controller
  4. Expand the Chassis Management Controller Firmware option and select View full driver details
  5. Scroll down to the Available formats section and Download the Update Package for Chassis Management Controller (CMC):  
    • M1000E: firmimg.cmc | FX2: fx2_cmc_X.XX.cmc | VRTX: vrtx_cmc.bin

Note: If you must download a previous version of the firmware, scroll down and expand the section for Other Available Versions, then select the version you want to download.


Follow these steps to update the CMC:

The recommended order to update redundant CMC:  

  • Start with updating the Standby.
  • Fail over the primary CMC.
  • Update the other Standby.
  • Fail the CMC over again so the original CMC is Primary.
  Steps:
  1. Chassis Overview > Update or Chassis Controller > Update
  2. Select the CMC to update and click Apply CMC Update
  3. Next to Firmware Image click Choose File
  4. Browse to the downloaded CMC firmware image and then click Begin firmware Update
    • If updating a standby CMC, wait for the update to complete then failover the CMC and repeat steps 1-4 afterwards to update the second CMC
    • Chassis Overview > Power > Control > Reset CMC (warm boot) > Apply

CMC Update Page

Figure 1: Image of CMC Firmware Update Page with two Redundant CMC. (With a single CMC configuration, only one active CMC is displayed.)

CMC Firmware Image Page

Figure 2: Image of CMC Firmware Image Page where you can select the image file and begin the update.

CMC Reset/Failover Page
Figure 3: Image of Chassis Power Control Page, only needed if updating a standby CMC in redundant configuration
 

How to Update Firmware for M1000E

This video demonstrates the updating procedure of a Firmware for the M1000e.


This video demonstrates the updating procedure of a Firmware for the M1000e.

受影响的产品

PowerEdge FX2/FX2s, PowerEdge M1000E, POWEREDGE VRTX
文章属性
文章编号: 000134801
文章类型: How To
上次修改时间: 26 9月 2024
版本:  8
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。