Collect logs on PowerEdge servers for advanced troubleshooting

摘要: If you have an issue, we recommend that you gather system logs to expedite the support process before contacting Dell Support. If you have logs available to send to the support agent, you can review them and analyze the issue immediately, which is the fastest possible resolution for your issue. This article explains some of the key tools available to collect logs. This includes the DSET, one of the best tools to collect logs for your Dell PowerEdge systems. ...

本文适用于   本文不适用于 

症状


If you have an issue, we recommend that you gather system logs to expedite the support process before contacting Dell Support. If you have logs available to send to the support agent, they can review them and quickly analyze the issue, which is the fastest possible resolution for your issue.

This article explains some of the key log gathering tools available, including SupportAssist Enterprise, the most comprehensive log gathering tool for your Dell PowerEdge system.


 

When is which tool useful?

The following table shows which tool can be used to obtain valid information about a specific issue source.

Tools Hard disk Memory CPU Operating system Blade Enclosures
iDRAC Integrated Dell Remote Access Controller Yes Yes Yes No No
Export PERC logs using software tools. Yes No No No No
Management Module Shared Storage Only No No No Yes

 

SLN292191_de__1icon Note: Blade chassis contain PowerEdge M1000e, PowerEdge VTRX chassis, and PowerEdge FX chassis.


Integrated Dell Remote Access Controller - iDRAC

The Dell iDRAC is integrated with most Dell PowerEdge servers. It does not require an installed operating system or hypervisor to function. You can access iDRAC using a web browser on the same network by using the IP address of the iDRAC (set up iDRAC ). For advanced troubleshooting, it is recommended to check the information provided, such as the status of the firmware and the System Event Log (SEL).

Related Articles:


 

Export PERC logs using software tools

An alternative to extract RAID controller logs for advanced analytics is to provide software tools such as the PERCCLI or Mega-CLI utilities for older controllers.

 

Management Module
Dell EMC PowerEdge MX7000 has a management module that provides chassis management. The Management Module supports high availability using a redundant module. An integral function of the management firmware is to maintain a detailed log of events from managed devices and software events in the management firmware. Firmware logs collected from Management Module components that can be used for troubleshooting are grouped as extract logs.
 
Retrieving logs from management module logs 


 
 

 

原因

      .

解决方案

      ..

受影响的产品

PowerEdge