메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스

PowerEdge: How to Install the MVCLI BOSS Utility on ESXI in order to determine the M.2 SSD Remaining Endurance

요약: When we come across certain false alerts reported by IDRAC in the LCC log, we want to confirm the BOSS M.2 SSD drive remaining endurance in order to assess the drive health. The instructions below demonstrate how to install the utility, run the commands to evaluate the BOSS M.2 SSD drive's health, and take appropriate action. ...

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

  • Download MVCLI BOSS Utility for ESXi CLI from the link (R650 chosen)
  • Transfer the file to your ESXI operating system.

The instructions to install this utility on the ESXi operating system are as follows:

# unzip DellEMC-BOSS-CLI_7.0.0-A00.zip
# esxcli software component apply -d /tmp/DellEMC-BOSS-CLI_7.0.0-A00-signed_component-15949364.zip


Virtual console 1 output shows installation output  


Run the below command to determine the M.2 SSD Physical Drive information connected on the BOSS card.

# cd /opt/dell/boss/
# ./mvcli info -o pd

Virtual console 2 shows the command output for mvcli info -o pd 

By gathering a TSR report or using IDRAC, we may evaluate and compare information concurrently.
iDRAC GUI 1 showing the storage controller output 

iDRAC GUI 2 highlights the SSDs on the BOSS 

iDRAC GUI 3 Disk 0 details 

iDRAC GUI 4 showing disk 1 details 

Perform the MVCLI BOSS Utility to perform the command listed below to check the Endurance or Life Remaining for Disk 0 M.2 SSD (PD 0).

# ./mvcli smart -p 0

Virtual console 3 highlights the life remaining output for the disk 0  

Perform the command shown below to check the SSD's endurance or Life Remaining for the Disk 1 M.2 SSD (PD 1) connected to the BOSS card.

# ./mvcli smart -p 1


Virtual console 4 highlights the life remaining on disk 1 

 

 

해당 제품

Boot Optimized Server Storage (BOSS), OEMR R240, OEMR R250, OEMR R340, OEMR R350, OEMR R440, PowerEdge XR2, OEMR R450, OEMR R540, OEMR R550, OEMR R5500, OEMR R640, OEMR XL R640, OEMR R6415, OEMR R650, OEMR R650xs, OEMR R740, OEMR XL R740, OEMR R740xd , OEMR XL R740xd, OEMR R740xd2, OEMR R7415, OEMR R7425, OEMR R750, OEMR R750xa, OEMR R750xs, OEMR R7515, OEMR R7525, OEMR R840, OEMR R940, OEMR R940xa, OEMR T340, OEMR T350, OEMR T440, OEMR T550, OEMR T640, OEMR XL R240, OEMR XL R340, OEMR XR11, OEMR XR12, Poweredge C4140, PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX840C, PowerEdge R240, PowerEdge R340, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R840, PowerEdge R940, PowerEdge R940xa, PowerEdge T140, PowerEdge T340, PowerEdge T440, PowerEdge T550, PowerEdge T640, PowerEdge XE8545, PowerEdge XR11, PowerEdge XR12, VMware ESXi 6.5.X, VMware ESXi 6.7.X, VMware ESXi 7.x, VMware ESXi 8.x, Dell EMC vSAN C6420 Ready Node, Dell EMC vSAN MX740c Ready Node, Dell EMC vSAN MX750c Ready Node, Dell EMC vSAN R440 Ready Node, Dell EMC vSAN R640 Ready Node, Dell EMC vSAN R6415 Ready Node, Dell EMC vSAN R650 Ready Node, Dell EMC vSAN R6515 Ready Node, Dell EMC vSAN R740 Ready Node, Dell EMC vSAN R740xd Ready Node, Dell EMC vSAN R750 Ready Node, Dell EMC vSAN R7515 Ready Node, Dell EMC vSAN R840 Ready Node, Dell EMC vSAN T350 Ready Node ...